The HRV system needs a yearly service
inspection.

Your installer will be able to offer you
an annual service which among other
checks will cover cleaning of the heat
exchanger and the fans. The heat
exchanger will usually only require
cleaning every 3 years. In case of
difficulty contact CVC Direct.

Filters will need to be replaced each
year.

Wireless Control

Your Brink HRV unit will usually be
supplied with a wired 4-position
switch. A wireless control system is
also available to enable you to control
the speed settings from any one
position or from multiple positions e.g.
if you want to switch to boost from the
kitchen, bathroom or toilet.

To set up your house for wireless
control you will require a receiver and
the necessary number of transmitters.

Receiver

The receiver is easy to install and
should be placed close to the Brink
HRV unit.

The receiver has a cable with a
communication plug which needs to
be connected, together with a splitter
on the top of the HRV.

Transmitter

Several transmitters can be set for one
receiver for instance in the bathroom
as well as the kitchen. The transmitters
can control all speed options and a
timer option. By pressing the timer
button you can set the system to boost
for 15 minutes (when cooking,
showering etc.). By holding the button
for more than one second you can
select the boost position for 30
minutes.

To order receivers and transmitters
contact CVC Direct.

Wireless

control

Maintenance & Optional Accessories

You can order new filters from CVC Direct at:

F7 pollen filter

G3 standard filter

http://cart.vacuumsdirect.co.uk/index.php?p=catalog&parent=65&pg=1

Содержание HRV Balanced

Страница 1: ...HRV Balanced Ventilation Systems Homeowners Manual WHOLE HOUSE VENTILATION UK distributor for Brink Climate Systems ...

Страница 2: ...nside Up to 95 of the heat which would normally be lost outside now stays inside because of the HRV system Congratulations Your home is fitted with a Brink HRV balanced ventilation system which will ensure healthy and comfortable indoor air quality whilst minimising energy usage Householders information This booklet has been produced to give you the householder some general guidance on the use and...

Страница 3: ...u want However in a well balanced ventilated dwelling this is not necessary In the summertime if the indoor temperature is becoming too high opening a window can provide additional ventilation with cooler air However if you open the window in the heating season extra energy is wasted in heating up the incoming cold air Remember the incoming air through the ventilation system is filtered and provid...

Страница 4: ...uality This is especially important in a new building There are two standard filters in the unit one to filter the incoming air bottom slot to ensure good internal air quality whilst the other filter top slot protects the heat exchanger An optional F7 Pollen filter may be fitted in the bottom slot replacing the standard filter On the display or on the 4 way switch of the Brink HRV you will get a s...

Страница 5: ...r will tend to cool the incoming warmer air although this will gradually result in an increase in the internal temperature This assumes that this is happening on a hot sunny day but at night the outside temperature will drop and as soon as the temperature of the outside air falls below that of the interior temperature i e the extracted air then the bypass opens to let in the cooler air without it ...

Страница 6: ...re a receiver and the necessary number of transmitters Receiver The receiver is easy to install and should be placed close to the Brink HRV unit The receiver has a cable with a communication plug which needs to be connected together with a splitter on the top of the HRV Transmitter Several transmitters can be set for one receiver for instance in the bathroom as well as the kitchen The transmitters...

Страница 7: ...re consumables on which there is no warranty Replacement filters can be purchased from your installer or from CVC Direct Register within 1 month You will need to send us the serial number of your machine situated on the top of the HRV unit and your full address Registration must occur within 1 month of installation of the HRV unit and can be done by email info cvcdirect co uk or by returning the c...

Отзывы: