Briggs & Stratton PowerBoss Скачать руководство пользователя страница 11

11

Operation

Starting the Engine

Disconnect all electrical loads from the generator. Use the
following start instructions:

1. Make sure unit is on a level surface.

NOTICE  

Failure to start and operate the unit on a level

surface will cause the unit not to start or shut down during
operation.

2. Make sure POWERSMART switch (

A

) is in “

Off or O

position.

3. Turn the engine switch (

B

) to the “

On or I

” position.

4. Turn fuel cap vent lever (

C

) to “

On or I

” position.

5. Push choke lever (

D

) to “

Choke

” position.

NOTICE  

To help start the engine for the very first time, after

running out of fuel or after a long period of storage, fill fuel
tank as described in 

Add Fuel

. It will require more than

several start attempts until the air in the fuel system has
been purged.

6A. Grasp recoil handle and pull slowly until slight resistance

is felt. Then pull rapidly to start engine. 

If engine starts, proceed to step 8.

If engine fails to start, proceed to step 7.

To start engine thereafter:

6B. Grasp recoil handle and pull slowly until slight resistance

is felt. Then pull rapidly one time only to start engine.

If engine starts, proceed to step 8.

If engine fails to start, proceed to step 7.

7. Move choke lever to half choke position, and pull recoil

handle twice.

If engine fails to start, repeat steps 5 thru 6.

8. Slowly move choke lever to “

Run

” position. If engine

falters, move choke lever to half choke position until
engine runs smoothly, and then to “

Run

” position.

NOTICE  

If engine floods, move choke lever to “

Run

position and crank until engine starts.

NOTICE  

If engine starts after 3 pulls but fails to run, or if

unit shuts down during operation, make sure unit is on a
level surface and check for proper oil level in crankcase. This
unit is equipped with a low oil protection device. If so, oil
must be at proper level for engine to start.

Connecting Electrical Loads

1. Make sure the green output indicator light comes on (it

may take up to three seconds).

2. Let engine stabilize and warm up for a few minutes

after starting.

3. Plug in and turn on the desired 240 Volt AC, single

phase, 50 Hz electrical loads.

C

B

A

D

WARNING   

Starter cord kickback (rapid retraction) will

pull hand and arm toward engine faster than you
can let go which could cause broken bones,
fractures, bruises, or sprains resulting in serious

injury.

• When starting engine, pull cord slowly until resistance is felt

and then pull rapidly to avoid kickback.

• NEVER start or stop engine with electrical devices plugged in

and turned on.

WARNING   

Exhaust heat/gases could ignite

combustibles, structures or damage fuel
tank causing a fire, resulting in death,
serious injury and/or property damage.

Contact with muffler area could cause burns resulting in
serious injury.

• DO NOT touch hot parts and AVOID hot exhaust gases.

• Allow equipment to cool before touching.

• Keep at least 1.5 m (5 ft.) of clearance on all sides of generator

including overhead.

• Contact the original equipment manufacturer, retailer, or dealer

to obtain a spark arrester designed for the exhaust system
installed on this engine.

• Replacement parts must be the same and installed in the same

position as the original parts.

Not 

for  

Reproduction

Содержание PowerBoss

Страница 1: ...BRIGGS STRATTON POWER PRODUCTS GROUP LLC MILWAUKEE WISCONSIN U S A Manual No 313733GS Revision Inverter Generator Operator s Manual N o t f o r R e p r o d u c t i o n...

Страница 2: ...ore attempting to start or operate this equipment Save these instructions for future reference This generator requires final assembly before use Refer to the Assembly section of this manual for instru...

Страница 3: ...ceptacles 10 Operation 11 Starting the Engine 11 Connecting Electrical Loads 11 Stopping the Engine 12 POWERSMART Mode 12 Charging a Battery 12 Don t Overload Generator 13 Maintenance 14 Maintenance S...

Страница 4: ...a hazard The warnings in this manual and the tags and decals affixed to the unit are therefore not all inclusive If you use a procedure work method or operating technique that the manufacturer does n...

Страница 5: ...ve OFF DO NOT tip engine or equipment at angle which causes fuel to spill Disconnect spark plug wire WHEN STORING FUEL OR EQUIPMENT WITH FUEL IN TANK Store away from furnaces stoves water heaters clot...

Страница 6: ...le standing in water while barefoot or while hands or feet are wet DO NOT allow unqualified persons or children to operate or service generator WARNING Exhaust heat gases could ignite combustibles str...

Страница 7: ...Fuel Fuel must meet these requirements Clean fresh unleaded gasoline A minimum of 87 octane 87 AKI 91 RON For high altitude use see High Altitude Gasoline with up to 10 ethanol gasohol or up to 15 MTB...

Страница 8: ...s that the AC stator winding is isolated from the grounding fastener and the AC receptacle ground pins On a floating neutral generator the AC receptacle ground pins are not functional Electrical devic...

Страница 9: ...eceptacle is protected by a push to reset circuit breaker J Grounding Fastener Consult your local agency having jurisdiction for grounding requirements in your area K POWERSMART Switch Use this switch...

Страница 10: ...and push the button in to reset the circuit breaker This receptacle allows you to recharge a 12 Volt automotive or utility style storage battery with the battery charge cable provided This receptacle...

Страница 11: ...o Run position and crank until engine starts NOTICE If engine starts after 3 pulls but fails to run or if unit shuts down during operation make sure unit is on a level surface and check for proper oil...

Страница 12: ...ent caps make sure they are installed and are tight 4 Connect battery charge cable clamp with red handle to battery post or terminal indicated by Positive POS or 5 Connect battery charge cable clamp w...

Страница 13: ...ze engine runs smoothly and attached device operates properly 4 Plug in and turn on the next load 5 Again permit the generator to stabilize 6 Repeat steps 4 and 5 for each additional load NEVER add mo...

Страница 14: ...aves or any other foreign material NOTICE DO NOT use water or other liquids to clean generator Liquids can enter engine fuel system causing poor performance and or failure to occur In addition if liqu...

Страница 15: ...eratures Use of synthetic oil does not alter required oil change intervals Checking Oil Level Oil level should be checked prior to each use or at least every 8 hours of operation Keep oil level mainta...

Страница 16: ...if you run it with a dirty air cleaner Service more often if operating under dirty or dusty conditions To service the air cleaner follow these steps 1 Loosen the side maintenance cover screws and rem...

Страница 17: ...er screen 3 Inspect screen and obtain a replacement if torn perforated or otherwise damaged DO NOT use a defective screen If screen is not damaged clean it with a brush 4 Reattach screen to muffler Re...

Страница 18: ...from crankcase Refill with recommended grade See Changing Engine Oil Other Storage Tips 1 DO NOT store fuel from one season to another unless it has been treated as described in Long Term Storage Ins...

Страница 19: ...to Off 2 Fuel cap vent lever is in Off position 3 Low oil indicator light comes on Low oil level 4 Dirty air cleaner 5 Out of fuel 6 Stale fuel 7 Spark plug wire not connected to spark plug 8 Bad spa...

Страница 20: ...enienced Any Authorized Service Dealer may perform warranty repairs Most warranty repairs are handled routinely but sometimes requests for warranty service may not be appropriate For example warranty...

Страница 21: ...21 N o t f o r R e p r o d u c t i o n...

Страница 22: ...22 www 1800generator com au N o t f o r R e p r o d u c t i o n...

Страница 23: ...23 N o t f o r R e p r o d u c t i o n...

Страница 24: ...utomotive Engineers code J1940 Small Engine Power Torque Rating Procedure and rating performance has been obtained and corrected in accordance with SAE J1995 Revision 2002 05 Torque values are derived...

Отзывы: