Starting Wattage . . . . . . . . . . . . . . . . . . . . . . . .2,000 Watts
Wattage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1,600 Watts
Load Current:
at 240 Volts AC . . . . . . . . . . . . . . . . . . . . . . . . .6.6 Amps
at 12 Volts DC . . . . . . . . . . . . . . . . . . . . . . . . . . .5 Amps
Rated Frequency . . . . . . . . . . . . . . . . . . . . . . . . . .50 Hertz
Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Single Phase
Displacement . . . . . . . . . . . . . . . . . . .105.6 cc (6.44 cu. in.)
Spark Plug Gap . . . . . . . . . . .0.6-0.7 mm (0.023-0.027 in.)
Intake Valve Clearance . . . . . . . . . . . . . . . . .0.08 - 0.12 mm
(0.0031 - 0.0047 in.) cold
Exhaust Valve Clearance . . . . . . . . . . . . . . .0.13 - 0.17 mm
(0.0051 - 0.0067 in.) cold
Fuel Capacity . . . . . . . . . . . . . . . . . .3.7 L (1.0 U.S. gallon)
Oil Capacity . . . . . . . . . . . . . . . . . .0.4 Liters (13.5 Ounces)
Common Service Parts
Foam Air Cleaner . . . . . . . . . . . . . . . . . . . . . . . . .311388GS
Breather Filter . . . . . . . . . . . . . . . . . . . . . . . . . . . .311389GS
Resistor Spark Plug . . . . . . . . . . . . . . . . . . . .NGK CR7HSA
Engine Oil Bottle . . . . . . . . . . . . . . . . . . .100005 or 100028
Synthetic Oil Bottle . . . . . . . . . . . . . . . . . . . . . . . . . .100074
Fuel Stabilizer . . . . . . . . . . . . . . . . . . . . . . .100002 or 5041
1800 436 372
Power Ratings:
The gross power rating for individual gas engine models is labeled in accordance with SAE (Society of
Automotive Engineers) code J1940 (Small Engine Power & Torque Rating Procedure), and rating performance has been
obtained and corrected in accordance with SAE J1995 (Revision 2002-05). Torque values are derived at 3060 RPM; horsepower
values are derived at 3600 RPM. Actual gross engine power will be lower and is affected by, among other things, ambient
operating conditions and engine-to-engine variability. Given both the wide array of products on which engines are placed and
the variety of environmental issues applicable to operating the equipment, the gas engine will not develop the rated gross power
when used in a given piece of power equipment (actual "on-site" or net power). This difference is due to a variety of factors
including, but not limited to, accessories (air cleaner, exhaust, charging, cooling, carburetor, fuel pump, etc.), application
limitations, ambient operating conditions (temperature, humidity, altitude), and engine-to-engine variability. Due to
manufacturing and capacity limitations, Briggs & Stratton may substitute an engine of higher rated power for this Series engine.
Not
for
Reproduction
Содержание PowerBoss
Страница 21: ...21 N o t f o r R e p r o d u c t i o n...
Страница 22: ...22 www 1800generator com au N o t f o r R e p r o d u c t i o n...
Страница 23: ...23 N o t f o r R e p r o d u c t i o n...