background image

3

SAFETY RULES

7000W Portable Generator

PowerBOSS™

3

• This generator does not meet U. S. Coast Guard Regulation

33CFR-183 and should not be used on marine applications.

• Failure to use the appropriate U. S. Coast Guard approved

generator could result in death or serious injury and/or
property damage.

WARNING

• When using generator for backup power, notify utility

company. Use approved transfer equipment to isolate
generator from electric utility.

• Use a ground fault circuit interrupter (GFCI) in any damp or

highly conductive area, such as metal decking or steel work.

• DO NOT touch bare wires or receptacles.
• DO NOT use generator with electrical cords which are worn,

frayed, bare or otherwise damaged.

• DO NOT operate generator in the rain or wet weather.
• DO NOT handle generator or electrical cords while standing

in water, while barefoot, or while hands or feet are wet.

• DO NOT allow unqualified persons or children to operate or

service generator.

Generator produces powerful voltage.
Failure to isolate generator from power utility
can result in death or injury to electric utility
workers due to backfeed of electrical energy.

WARNING

• Operate generator ONLY outdoors.

• Keep exhaust gas from entering a confined area through

windows, doors, ventilation intakes or other openings.

• DO NOT operate generator inside any building or enclosure

(even if doors or windows are open), including the generator
compartment of a recreational vehicle (RV).

Running generator gives off carbon monoxide,
an odorless, colorless, poison gas.
Breathing carbon monoxide can cause nausea,
fainting or death.

WARNING

WHEN ADDING OR DRAINING FUEL
• Turn generator OFF and let it cool at least 2 minutes before

removing fuel cap. Loosen cap slowly to relieve pressure in
tank.

• Fill or drain fuel tank outdoors.

• DO NOT overfill tank. Allow space for fuel expansion.

• Wait for spilled fuel to evaporate before starting engine.

• Keep fuel away from sparks, open flames, pilot lights, heat, and

other ignition sources.

• DO NOT light a cigarette or smoke.

WHEN STARTING EQUIPMENT
• Ensure spark plug, muffler, fuel cap and air cleaner are in place.

• DO NOT crank engine with spark plug removed.

WHEN OPERATING EQUIPMENT
• DO NOT tip engine or equipment at angle which causes fuel

to spill.

• This generator is not for use in mobile equipment or marine

applications.

WHEN TRANSPORTING OR REPAIRING
EQUIPMENT
• Transport/repair with fuel tank EMPTY or with fuel shutoff

valve OFF.

• Disconnect spark plug wire.

WHEN STORING FUEL OR EQUIPMENT WITH FUEL
IN TANK
• Store away from furnaces, stoves, water heaters, clothes

dryers or other appliances that have pilot light or other
ignition source because they can ignite fuel vapors.

Fuel and its vapors are extremely flammable and
explosive.
Fire or explosion can cause severe burns or
death.

WARNING

Using a generator indoors WILL KILL YOU 
IN MINUTES. 

Exhaust contains carbon monoxide, a 
poison gas you cannot see or smell. 

NEVER use in the home 

or in partly enclosed 

areas such as garages. 

ONLY use outdoors and 

far from open windows, 

doors, and vents. 

Содержание PowerBoss 030220

Страница 1: ...a Generador Helpline 1 800 743 4115 M F 8 5 CT web www briggsandstratton com PowerBOSS is a trademark of Briggs Stratton Power Products PowerBOSS es una marca registrada de Briggs Stratton Power Produ...

Страница 2: ...mation refer to the engine operator s manual SAFETY RULES This is the safety alert symbol It is used to alert you to potential personal injury hazards Obey all safety messages that follow this symbol...

Страница 3: ...eational vehicle RV Running generator gives off carbon monoxide an odorless colorless poison gas Breathing carbon monoxide can cause nausea fainting or death WARNING WHEN ADDING OR DRAINING FUEL Turn...

Страница 4: ...ING REPAIRS TOYOUR GENERATOR Disconnect the spark plug wire from the spark plug and place the wire where it cannot contact spark plug WHEN TESTING FOR ENGINE SPARK Use approved spark plug tester DO NO...

Страница 5: ...electrical overload Data Tag Provides model revision and serial number of generator Please have these readily available when calling for assistance Engine Switch Set this switch to On before using re...

Страница 6: ...the portability of your generator NOTE Wheel kit is not intended for over the road use You will need the following tools to install this wheel kit 13mm socket wrench 13mm open end wrench Pliers Safet...

Страница 7: ...bearing Add Fuel NOTE This gasoline engine is certified to operate on gasoline Exhaust Emission Control System EM Engine Modifications 1 Use clean fresh regular UNLEADED gasoline with a minimum of 87...

Страница 8: ...haust gas is kept away from any windows doors ventilation intakes or other openings that can allow exhaust gas to collect in a confined area Figure 3 Prevailing winds and air currents should be taken...

Страница 9: ...wly until resistance is felt and then pull rapidly to avoid kickback NEVER start or stop engine with electrical devices plugged in and turned on Rapid retraction of starter cord kickback will pull han...

Страница 10: ...st overload by a push to reset circuit breaker Use each receptacle to operate 120 Volt AC single phase 60 Hz electrical loads requiring up to 2 400 watts 2 4 kW at 20 Amps of current Use cord sets tha...

Страница 11: ...or making sure muffler side of generator is exposed NOTE Structure should hold enough heat created by the generator to prevent icing problem 2 DO NOT enclose generator any more than shown in Figure 7...

Страница 12: ...generator output to stabilize engine runs smoothly and attached device operates properly 4 Plug in and turn on the next load 5 Again permit the generator to stabilize 6 Repeat steps 4 and 5 for each...

Страница 13: ...rden hose to clean generator Water can enter engine fuel system and cause problems In addition if water enters generator through cooling air slots some of the water will be retained in voids and crack...

Страница 14: ...ent gum from forming in fuel system or on essential carburetor parts add fuel stabilizer into fuel tank and fill with fresh fuel Run the unit for several minutes to circulate the additive through the...

Страница 15: ...is in good condition Generator runs good at no load but bogs down when loads are connected 1 Short circuit in a connected load 2 Generator is overloaded 3 Shorted generator circuit 1 Disconnect shorte...

Страница 16: ...16 PowerBOSS 7000W Portable Generator NOTES NOTES...

Страница 17: ...and apologize to you for being inconvenienced Any Authorized Service Dealer may perform warranty repairs Most warranty repairs are handled routinely but sometimes requests for warranty service may no...

Страница 18: ...tecci n Ambiental y el Consejo de recursos de aire de California Para mayor informaci n acerca de la garant a consulte con el manual del operario del motor REGLAS DE SEGURIDAD ste es el s mbolo de ale...

Страница 19: ...spas llamas abiertas pilotos calor y otras fuentes de ignici n NO encienda un cigarrillo o fume CUANDO PONGA EN FUNCIONAMIENTO EL EQUIPO Compruebe que la buj a el silenciador el tap n del dep sito de...

Страница 20: ...RADOR Siempre desconecte el alambre de la buj a y col quelo donde no pueda entrar en contacto con la buj a CUANDO PRUEBE LA BUJ A DEL MOTOR Utilice un comprobador de buj as homologado NO comprueba la...

Страница 21: ...ci n On En para darle arranque al motor Col quelo en la posici n Off Apagado para detener un motor en funcionamiento Palanca del Cebador Usada cuando se est dando arranque a un motor fr o Silenciador...

Страница 22: ...A Este Juego de Ruedas no ha sido dise ado para ser usado en la carretera Necesitar las siguientes herramientas para instalar estos componentes llave de cubo de 13 mm llave fija de 13 mm alicates gafa...

Страница 23: ...cape EM Modificaciones del motor 1 Utilice combustible normal sin plomo limpia y nueva con un m nimo de 87 octanos NO utilice combustible que contenga metanol ni mezcle aceite con combustible 2 Limpie...

Страница 24: ...dan acumularse Figura 11 Tenga en cuenta los vientos y las corriente de aire preponderantes cuando elija la ubicaci n del generador Cuando use un generador como poder de energ a auxiliar notifique a l...

Страница 25: ...as cargas el ctricas en la posici n de apagado OFF luego encienda ON para su operaci n Apague OFF las cargas el ctricas y descon ctelas del generador antes de parar el generador El sobrepasar la capac...

Страница 26: ...20Voltios AC de fase sencilla de cargas de 60Hz que requieren hasta 2 400 vatios 2 4 kW a corrientes de 20 Amperios Use los juegos de cables que son calificados para cargas de 125Voltios AC a 20 Amper...

Страница 27: ...l generador asegur ndose de que el lado del silenciador quede expuesto NOTA La estructura debe mantener una cantidad suficiente del calor disipado por el generador para evitar problemas de congelaci n...

Страница 28: ...r funciona suavemente y el aparato conectado al mismo trabaja adecuadamente 4 Conecte y encienda la pr xima carga 5 De nuevo permita que el generador se estabilice 6 Repita los pasos 4 y 5 para cada c...

Страница 29: ...TA NO recomendamos el uso de mangueras de jard n para limpiar el generador El agua podr a introducirse en el sistema de combustible del motor y causar problemas Adem s si el agua se introduce al gener...

Страница 30: ...do Para evitar la formaci n de carbonilla en el circuito de combustible o en piezas esenciales del carburador a ada estabilizador de combustible al dep sito de combustible y llene este de gasolina nue...

Страница 31: ...orizado El motor funciona bien sin carga pero funciona mal cuando se le contectan cargas 1 Corto circuito en una de las cargas conectadas 2 El generador est sobrecarga 3 Circuito del generador en cort...

Страница 32: ...tarios destinados al mantenimiento de las constantes vitales Esta garant a excluye los fallos debidos a hechos fortuitos y a otros acontecimientos de fuerza mayor que escapan al control del fabricante...

Отзывы: