background image

5500W Portable Generator

4

• Use generator only for intended uses.

• If you have questions about intended use, ask dealer or call

1-800-743-4115.

• Operate generator only on level surfaces.

• DO NOT expose generator to excessive moisture, dust, dirt,

or corrosive vapors.

• DO NOT insert any objects through cooling slots.

• If connected devices overheat, turn them off and disconnect

them from generator.

• Shut off generator if:

-electrical output is lost;
-equipment sparks, smokes, or emits flames;
-unit vibrates excessively.

Improper treatment of generator can damage it and
shorten its life.

CAUTION

• DO NOT tamper with governed speed. Generator supplies

correct rated frequency and voltage when running at governed
speed.

• DO NOT modify generator in any way.

Excessively high operating speeds increase risk of injury
and damage to generator.
Excessively low speeds impose a heavy load.

CAUTION

• See “Don’t Overload Generator”.

• Start generator and let engine stabilize before connecting

electrical loads.

• Connect electrical loads in OFF position, then turn ON for

operation.

• Turn electrical loads OFF and disconnect from generator

before stopping generator.

Exceeding generators wattage/amperage capacity can
damage generator and/or electrical devices connected
to it.

CAUTION

WHEN ADJUSTING OR MAKING REPAIRS TO YOUR
GENERATOR
• Disconnect the spark plug wire from the spark plug and place

the wire where it cannot contact spark plug.

WHEN TESTING FOR ENGINE SPARK
• Use approved spark plug tester.

• DO NOT check for spark with spark plug removed.

Unintentional sparking can result in fire or
electric shock.

WARNING

• DO NOT touch hot surfaces and avoid hot exhaust gases.

• Allow equipment to cool before touching.

• Keep at least 5 ft. (152 cm) clearance on all sides of generator

including overhead.

• Code of Federal Regulation (CFR) Title 36 Parks, Forests, and

Public Property require equipment powered by an internal
combustion engine to have a spark arrester, maintained in
effective working order, complying to USDA Forest service
standard 5100-1C or later revision. In the State of California a
spark arrester is required under section 4442 of the California
Public resources code. Other states may have similar laws.

Running engines produce heat.Temperature of
muffler and nearby areas can reach or exceed
150°F (65°C).
Severe burns can occur on contact.
Exhaust heat/gases can ignite combustibles,
structures or damage fuel tank causing a fire.

WARNING

Содержание Elite 030209-1

Страница 1: ...M F 8 5 CT Llamada Generador Helpline 1 800 743 4115 M F 8 5 CT web www briggsandstratton com 030209 1 5500W BRIGGS STRATTON POWER PRODUCTS GROUP LLC JEFFERSON WISCONSIN U S A Before using this produc...

Страница 2: ...formation refer to the Engine Operator s Manual SAFETY RULES This is the safety alert symbol It is used to alert you to potential personal injury hazards Obey all safety messages that follow this symb...

Страница 3: ...arette or smoke WHEN STARTING EQUIPMENT Ensure spark plug muffler fuel cap and air cleaner are in place DO NOT crank engine with spark plug removed If fuel spills wait until it evaporates before start...

Страница 4: ...ore stopping generator Exceeding generators wattage amperage capacity can damage generator and or electrical devices connected to it CAUTION WHEN ADJUSTING OR MAKING REPAIRS TOYOUR GENERATOR Disconnec...

Страница 5: ...l number of generator Please have these readily available when calling for assistance Fuel Tank Capacity of seven 7 U S gallons Grounding Fastener Consult your local agency having jurisdiction for gro...

Страница 6: ...ntents against those listed below Main unit Engine oil Operator s manual Engine operator s manual Wheel kit If any parts are missing or damaged call the generator helpline at 1 800 743 4115 Install Wh...

Страница 7: ...NOT use fuel which contains Methanol DO NOT mix oil with fuel 2 Clean area around fuel fill cap remove cap 3 Slowly add regular unleaded fuel to fuel tank Be careful not to overfill Allow about 1 5 of...

Страница 8: ...as to collect in a confined area Figure 3 Prevailing winds and air currents should be taken into consideration when positioning generator When using generator for backup power notify utility company U...

Страница 9: ...or and let engine stabilize before connecting electrical loads Connect electrical loads in OFF position then turn ON for operation Turn electrical loads OFF and disconnect from generator before stoppi...

Страница 10: ...ds requiring up to 5 500 watts of power 5 5 kW at 22 9 Amps for 240 Volts or two independent 120 Volt loads at 20 Amps each The outlet is protected by push to reset circuit breakers 120 Volt AC 20 Amp...

Страница 11: ...r output to stabilize engine runs smoothly and attached device operates properly 4 Plug in and turn on the next load 5 Again permit the generator to stabilize 6 Repeat steps 4 and 5 for each additiona...

Страница 12: ...ater can enter engine fuel system and cause problems In addition if water enters generator through cooling air slots some of the water will be retained in voids and cracks of the rotor and stator wind...

Страница 13: ...rom forming in fuel system or on essential carburetor parts add fuel stabilizer into fuel tank and fill with fresh fuel Run the unit for several minutes to circulate the additive through the carbureto...

Страница 14: ...no load but bogs down when loads are connected 1 Short circuit in a connected load 2 Generator is overloaded 3 Shorted generator circuit 1 Disconnect shorted electrical load 2 See Don t Overload Gener...

Страница 15: ...ctric powered pressure washers used for commercial purposes are not warranted NO WARRANTY REGISTRATION IS NECESSARY TO OBTAIN WARRANTY ON BRIGGS STRATTON PRODUCTS SAVE YOUR PROOF OF PURCHASE RECEIPT I...

Страница 16: ...n Ambiental y el Consejo de recursos de aire de California Para mayor informaci n acerca de la garant a consulte con el Manual del Operario de Motor REGLAS DE SEGURIDAD ste es el s mbolo de alerta de...

Страница 17: ...a el silenciador el tap n del dep sito de combustible y el filtro de aire est n instalados NO arranque el motor sin la buj a instalada Si se ha derramado combustible espere a que se evapore antes de a...

Страница 18: ...ador antes de parar el generador El sobrepasar la capacidad del amperaje y vataje del generador puede da ar al generador y los aparatos el ctricos conectados al mismo PRECAUCI N CUANDO AJUSTE O HAGA R...

Страница 19: ...a posici n Off Apagado para detener un motor en funcionamiento Palanca del Cebador Usada cuando se est dando arranque a un motor fr o Tapa del Dep sito del Aceite Llene el motor con aceite aqu Tanque...

Страница 20: ...l cart n para instalar el juego de ruedas Contenido de la Caja Revise todo el contenido compar ndolo con la lista a continuaci n Unidad Principal Aceite del Motor Manual del Operario Manual del Operar...

Страница 21: ...5 octanos NO utilice combustible que contenga metanol ni mezcle aceite con combustible 2 Limpie el rea alrededor de la tapa de llenado del combustible retire la tapa 3 Agregue lentamente combustible r...

Страница 22: ...n del generador Cuando use un generador como poder de energ a auxiliar notifique a la compa a de utilidades Use el equipo de transferencia aprobado para aislar el generador de otra utilidad el ctrica...

Страница 23: ...las cargas el ctricas y descon ctelas del generador antes de parar el generador El sobrepasar la capacidad del amperaje y vataje del generador puede da ar al generador y los aparatos el ctricos conect...

Страница 24: ...a 22 9 Amperios para 120 Voltios 5 500 vatios de energ a 5 5 kW a 22 9 Amperios para 240 Voltios La salida est protegida por un corto circuito de del tipo empuje para reposicionar 120 Volt AC 20 Amp...

Страница 25: ...suavemente y el aparato conectado al mismo trabaja adecuadamente 4 Conecte y encienda la pr xima carga 5 De nuevo permita que el generador se estabilice 6 Repita los pasos 4 y 5 para cada carga adici...

Страница 26: ...angueras de jard n para limpiar el generador El agua podr a introducirse en el sistema de combustible del motor y causar problemas Adem s si el agua se introduce al generador a trav s de las ranuras p...

Страница 27: ...xidarse El xido y o la suciedad en la gasolina le causar problemas Almacene la unidad en un rea limpia y seca DIAGNOSITICOS DE AVER AS Problemo Accion Causa El motor est funcionando pero no existe sal...

Страница 28: ...VICIO DE BRIGGS STRATTON PRODUCTS GUARDE SU RECIBO DE COMPRA SI NO APORTA LA PRUEBA DE LA FECHA DE COMPRA INICIAL SE UTILIZAR LA FECHA DE FABRICACI N DEL PRODUCTO PARA DETERMINAR EL PER ODO DE GARANT...

Отзывы: