7

System Ground

The generator has a system ground that connects the
generator frame components to the ground terminals on the
AC output receptacles. The system ground is connected to
the AC neutral wire (the neutral is bonded to the generator
frame).

Special Requirements

There may be Federal or State Occupational Safety and
Health Administration (OSHA) regulations, local codes, or
ordinances that apply to the intended use of the generator.
Please consult a qualified electrician, electrical inspector, or
the local agency having jurisdiction:

• In some areas, generators are required to be registered

with local utility companies.

• If the generator is used at a construction site, there

may be additional regulations which must be observed.

Connecting to a Building’s Electrical System

Connections for standby power to a building’s electrical
system must be made by a qualified electrician. The
connection must isolate the generator power from utility
power or other alternative power sources and must comply
with all applicable laws and electrical codes.

Generator Location

Clearances and Air Movement

Place generator outdoors in an area that will not accumulate
deadly exhaust gas. DO NOT place generator where exhaust
gas (

A

) could accumulate and enter inside or be drawn into a

potentially occupied building. Ensure exhaust gas is kept
away from any windows, doors, ventilation intakes, or other
openings that can allow exhaust gas to collect in a confined
area. Prevailing winds and air currents should be taken into
consideration when positioning generator.

A

WARNING

Generator produces hazardous voltage.

Failure to isolate generator from power utility can
result in death or injury to electric utility workers
due to backfeed of electrical energy.

• When using generator for backup power, notify utility company.

Use approved transfer equipment to isolate generator from
electric utility.

• Use a ground fault circuit interrupter (GFCI) in any damp or

highly conductive area, such as metal decking or steel work.

• DO NOT touch bare wires or receptacles.

• DO NOT use generator with electrical cords which are worn,

frayed, bare or otherwise damaged.

• DO NOT operate generator in the rain or wet weather.

• DO NOT handle generator or electrical cords while standing in

water, while barefoot, or while hands or feet are wet.

• DO NOT allow unqualified persons or children to operate or

service generator.

WARNING

Exhaust heat / gases can ignite combustibles,
structures or damage fuel tank causing a fire.

• Keep at least 5 ft. (1.5 m) clearance on all sides of generator

including overhead.

Содержание 3500 Watt Portable Generator

Страница 1: ...Manual No 203476GS Revision A 04 16 2007 BRIGGS STRATTON POWER PRODUCTS GROUP LLC JEFFERSON WISCONSIN U S A 3500 Watt Portable Generator Operator s Manual...

Страница 2: ...how to avoid them Because Briggs Stratton does not necessarily know all the applications this generator could be used for it is important that you read and understand these instructions thoroughly bef...

Страница 3: ...l System 7 Generator Location 7 Features and Controls 8 Cord Sets and Receptacles 9 Operation 10 Starting the Engine 10 Connecting Electrical Loads 11 Stopping the Engine 11 Don t Overload Generator 1...

Страница 4: ...ury NOTICE indicates a situation that could result in equipment damage Follow safety messages to avoid or reduce the risk of injury or death The manufacturer cannot possibly anticipate every possible...

Страница 5: ...stop engine with electrical devices plugged in and turned on WARNING Fuel and its vapors are extremely flammable and explosive Fire or explosion can cause severe burns or death WHEN ADDING OR DRAINING...

Страница 6: ...ire where it cannot contact spark plug WHEN TESTING FOR ENGINE SPARK Use approved spark plug tester DO NOT check for spark with spark plug removed CAUTION Excessively high operating speeds increase ri...

Страница 7: ...he generator is supplied with Engine oil bottle Operator s manual Wheel kit Install Wheel Kit NOTE Wheel kit is not intended for over the road use You will need the following tools to install these co...

Страница 8: ...At altitudes over 5 000 feet 1524 meters a minimum 85 octane 85 AKI 89 RON gasoline is acceptable To remain emissions compliant high altitude adjustment is required Operation without this adjustment...

Страница 9: ...DO NOT place generator where exhaust gas A could accumulate and enter inside or be drawn into a potentially occupied building Ensure exhaust gas is kept away from any windows doors ventilation intakes...

Страница 10: ...e used to supply electrical power for the operation of 120 Volt AC 20 Amp single phase 60 Hz electrical lighting appliance tool and motor loads H 120 240 Volt AC 20 Amp Locking Receptacle May be used...

Страница 11: ...e phase loads requiring up to 3 500 watts of power 3 5 kW at 14 5 Amps for 240 Volts or two independent 120 Volt loads at 14 5 Amps each The outlet is protected by push to reset circuit breakers 120 V...

Страница 12: ...ion make sure the unit is on a level surface and check for the proper oil level in the crankcase This unit may be equipped with a low oil protection device 10 BRIGGSandSTRATTON COM WARNING Starter cor...

Страница 13: ...rned ON 2 Let engine run at no load for several minutes to stabilize internal temperatures of engine and generator 3 Push engine rocker switch to Off position 4 Move fuel valve to Off position 11 WARN...

Страница 14: ...ngine runs smoothly and attached device operates properly 4 Plug in and turn on the next load 5 Again permit the generator to stabilize 6 Repeat steps 4 and 5 for each additional load NEVER add more l...

Страница 15: ...l not be exposed to excessive dust dirt moisture or any corrosive vapors Cooling air slots in the generator must not become clogged with snow leaves or any other foreign material NOTE DO NOT use water...

Страница 16: ...ing 4 Replace and tighten oil fill cap Adding Engine Oil 1 Make sure generator is on a level surface 2 Check oil level as described in Checking Oil Level 3 If needed slowly pour oil into oil fill open...

Страница 17: ...et spark plug gap to recommended gap if necessary see Specifications 4 Replace spark plug if electrodes are pitted burned or porcelain is cracked Use the recommended replacement spark plug See Specifi...

Страница 18: ...tton service dealer clean the cooling system per recommended intervals see Maintenance Schedule in beginning of Maintenance section Equally important is to keep top of engine free from debris See Clea...

Страница 19: ...ded grade See Changing Engine Oil Oil Cylinder Bore Remove spark plug and pour about 1 2 ounce 15 ml of clean engine oil into the cylinder Install spark plug and pull starter handle slowly to distribu...

Страница 20: ...set to Off 2 Fuel Valve is in Off position 3 Dirty air cleaner 4 Out of fuel 5 Stale fuel 6 Spark plug wire not connected to spark plug 7 Bad spark plug 8 Water in fuel 9 Flooded 10 Excessively rich f...

Страница 21: ...ur Operating and Maintenance Instructions B S recommends that you retain all your receipts covering maintenance on your small off road engine but B S cannot deny warranty solely for the lack of receip...

Страница 22: ...maintenance or repairs The owner is responsible for the performance of all required maintenance as defined in the B S Operator s Manual 6 Consequential Coverage Coverage hereunder shall extend to the...

Страница 23: ...nd apologize to you for being inconvenienced Any Authorized Service Dealer may perform warranty repairs Most warranty repairs are handled routinely but sometimes requests for warranty service may not...

Страница 24: ...iven piece of power equipment actual on site or net power This difference is due to a variety of factors including but not limited to accessories air cleaner exhaust charging cooling carburetor fuel p...

Отзывы: