Briggs & Stratton 3500 Watt Portable Generator Скачать руководство пользователя страница 6

4

BRIGGSandSTRATTON.COM

WARNING

Contact with muffler area can result in serious
burns.

Exhaust heat / gases can ignite combustibles,
structures or damage fuel tank causing a fire.

• DO NOT touch hot parts and AVOID hot exhaust gases.

• Allow equipment to cool before touching.

• Keep at least 5 feet (1.5 m) of clearance on all sides of

generator including overhead.

• Code of Federal Regulation (CFR) Title 36 Parks, Forests, and

Public Property require equipment powered by an internal
combustion engine to have a spark arrester, maintained in
effective working order, complying to USDA Forest service
standard 5100-1C or later revision. In the State of California a
spark arrester is required under section 4442 of the California
Public resources code. Other states may have similar laws.

WARNING

Starter and other rotating parts can entangle
hands, hair, clothing, or accessories.

• NEVER operate generator without protective housing or covers.

• DO NOT wear loose clothing, jewelry or anything that may be

caught in the starter or other rotating parts.

• Tie up long hair and remove jewelry.

WARNING

Unintentional sparking can result in fire or
electric shock.

WHEN ADJUSTING OR MAKING REPAIRS TO YOUR GENERATOR

• Disconnect the spark plug wire from the spark plug and place

the wire where it cannot contact spark plug.

WHEN TESTING FOR ENGINE SPARK

• Use approved spark plug tester.

• DO NOT check for spark with spark plug removed.

CAUTION

Excessively high operating speeds increase risk of injury
and damage to generator.

Excessively low speeds impose a heavy load.

• DO NOT tamper with governed speed. Generator supplies

correct rated frequency and voltage when running at governed
speed.

• DO NOT modify generator in any way.

NOTICE

Improper treatment of generator can damage it and
shorten its life.

• Use generator only for intended uses.

• If you have questions about intended use, ask dealer or contact

local service center.

• Operate generator only on level surfaces.

• DO NOT expose generator to excessive moisture, dust, dirt, or

corrosive vapors.

• DO NOT insert any objects through cooling slots.

• If connected devices overheat, turn them off and disconnect

them from generator.

• Shut off generator if:

-electrical output is lost;
-equipment sparks, smokes, or emits flames;
-unit vibrates excessively.

NOTICE

Exceeding generators wattage/amperage capacity can
damage generator and/or electrical devices connected to it.

• DO NOT exceed the generator’s wattage/amperage capacity. See

Don’t Overload Generator

in the 

Operation

section.

• Start generator and let engine stabilize before connecting

electrical loads.

• Connect electrical loads in OFF position, then turn ON for

operation.

• Turn electrical loads OFF and disconnect from generator before

stopping generator.

Содержание 3500 Watt Portable Generator

Страница 1: ...Manual No 203476GS Revision A 04 16 2007 BRIGGS STRATTON POWER PRODUCTS GROUP LLC JEFFERSON WISCONSIN U S A 3500 Watt Portable Generator Operator s Manual...

Страница 2: ...how to avoid them Because Briggs Stratton does not necessarily know all the applications this generator could be used for it is important that you read and understand these instructions thoroughly bef...

Страница 3: ...l System 7 Generator Location 7 Features and Controls 8 Cord Sets and Receptacles 9 Operation 10 Starting the Engine 10 Connecting Electrical Loads 11 Stopping the Engine 11 Don t Overload Generator 1...

Страница 4: ...ury NOTICE indicates a situation that could result in equipment damage Follow safety messages to avoid or reduce the risk of injury or death The manufacturer cannot possibly anticipate every possible...

Страница 5: ...stop engine with electrical devices plugged in and turned on WARNING Fuel and its vapors are extremely flammable and explosive Fire or explosion can cause severe burns or death WHEN ADDING OR DRAINING...

Страница 6: ...ire where it cannot contact spark plug WHEN TESTING FOR ENGINE SPARK Use approved spark plug tester DO NOT check for spark with spark plug removed CAUTION Excessively high operating speeds increase ri...

Страница 7: ...he generator is supplied with Engine oil bottle Operator s manual Wheel kit Install Wheel Kit NOTE Wheel kit is not intended for over the road use You will need the following tools to install these co...

Страница 8: ...At altitudes over 5 000 feet 1524 meters a minimum 85 octane 85 AKI 89 RON gasoline is acceptable To remain emissions compliant high altitude adjustment is required Operation without this adjustment...

Страница 9: ...DO NOT place generator where exhaust gas A could accumulate and enter inside or be drawn into a potentially occupied building Ensure exhaust gas is kept away from any windows doors ventilation intakes...

Страница 10: ...e used to supply electrical power for the operation of 120 Volt AC 20 Amp single phase 60 Hz electrical lighting appliance tool and motor loads H 120 240 Volt AC 20 Amp Locking Receptacle May be used...

Страница 11: ...e phase loads requiring up to 3 500 watts of power 3 5 kW at 14 5 Amps for 240 Volts or two independent 120 Volt loads at 14 5 Amps each The outlet is protected by push to reset circuit breakers 120 V...

Страница 12: ...ion make sure the unit is on a level surface and check for the proper oil level in the crankcase This unit may be equipped with a low oil protection device 10 BRIGGSandSTRATTON COM WARNING Starter cor...

Страница 13: ...rned ON 2 Let engine run at no load for several minutes to stabilize internal temperatures of engine and generator 3 Push engine rocker switch to Off position 4 Move fuel valve to Off position 11 WARN...

Страница 14: ...ngine runs smoothly and attached device operates properly 4 Plug in and turn on the next load 5 Again permit the generator to stabilize 6 Repeat steps 4 and 5 for each additional load NEVER add more l...

Страница 15: ...l not be exposed to excessive dust dirt moisture or any corrosive vapors Cooling air slots in the generator must not become clogged with snow leaves or any other foreign material NOTE DO NOT use water...

Страница 16: ...ing 4 Replace and tighten oil fill cap Adding Engine Oil 1 Make sure generator is on a level surface 2 Check oil level as described in Checking Oil Level 3 If needed slowly pour oil into oil fill open...

Страница 17: ...et spark plug gap to recommended gap if necessary see Specifications 4 Replace spark plug if electrodes are pitted burned or porcelain is cracked Use the recommended replacement spark plug See Specifi...

Страница 18: ...tton service dealer clean the cooling system per recommended intervals see Maintenance Schedule in beginning of Maintenance section Equally important is to keep top of engine free from debris See Clea...

Страница 19: ...ded grade See Changing Engine Oil Oil Cylinder Bore Remove spark plug and pour about 1 2 ounce 15 ml of clean engine oil into the cylinder Install spark plug and pull starter handle slowly to distribu...

Страница 20: ...set to Off 2 Fuel Valve is in Off position 3 Dirty air cleaner 4 Out of fuel 5 Stale fuel 6 Spark plug wire not connected to spark plug 7 Bad spark plug 8 Water in fuel 9 Flooded 10 Excessively rich f...

Страница 21: ...ur Operating and Maintenance Instructions B S recommends that you retain all your receipts covering maintenance on your small off road engine but B S cannot deny warranty solely for the lack of receip...

Страница 22: ...maintenance or repairs The owner is responsible for the performance of all required maintenance as defined in the B S Operator s Manual 6 Consequential Coverage Coverage hereunder shall extend to the...

Страница 23: ...nd apologize to you for being inconvenienced Any Authorized Service Dealer may perform warranty repairs Most warranty repairs are handled routinely but sometimes requests for warranty service may not...

Страница 24: ...iven piece of power equipment actual on site or net power This difference is due to a variety of factors including but not limited to accessories air cleaner exhaust charging cooling carburetor fuel p...

Отзывы: