background image

6200W Portable Generator

13

DON'T OVERLOAD

GENERATOR

Capacity

You must make sure your generator can supply
enough rated (running) and surge (starting) watts for
the items you will power at the same time. Follow
these simple steps:
1.

Select the items you will power at the same time.

2.

Total the rated (running) watts of these items. This
is the amount of power your generator must
produce to keep your items running. See Figure 9.

3.

Estimate how many surge (starting) watts you will
need. Surge wattage is the short burst of power
needed to start electric motor-driven tools or
appliances such as a circular saw or refrigerator.
Because not all motors start at the same time,
total surge watts can be estimated by adding only
the item(s) with the highest additional surge watts
to the total rated watts from step 2.

Example:

Total Rated (Running) Watts

= 3075

Highest Additional Surge Watts

= 1800

Total Generator Output Required

= 4875

Power Management

To prolong the life of your generator and attached
devices, it is important to take care when adding
electrical loads to your generator. There should be
nothing connected to the generator outlets before
starting it's engine. The correct and safe way to manage
generator power is to sequentially add loads as follows:
1.

With nothing connected to the generator, start the
engine as described in this manual.

2.

Plug in and turn on the first load, preferably the
largest load you have.

3.

Permit the generator output to stabilize (engine runs
smoothly and attached device operates properly.

4.

Plug in and turn on the next load.

5.

Again, permit the generator to stabilize.

6.

Repeat steps 4 and 5 for each additional load.

NEVER add more loads than the generator capacity.
Take special care to consider surge loads in generator
capacity, as described above.

*Wattages listed are approximate only. Check tool or
appliance for actual wattage.

Tool or Appliance

Rated (Running)

Watts

Additional Surge

(Starting) Watts

Window Air
Conditioner

1200

1800

Refrigerator

800

1600

Deep Freezer

500

500

Television

500

-

Light (75 Watts)

75

-

3075 Total

Running Watts

1800 Highest

Surge Watts

Tool or Appliance 

Rated* 

(Running) 

Watts 

Additional 

Surge 

(Starting) 

Watts 

Essentials 

 

 

Light Bulb - 75 watt 

75 

Deep Freezer 

500 

500 

Sump Pump 

800 

1200 

Refrigerator/Freezer - 18 Cu. Ft. 

800 

1600 

Water Well Pump - 1/3 HP 

1000 

2000 

Heating/Cooling 

 

 

Window AC - 10,000 BTU 

1200 

1800 

Window Fan 

300 

600 

Furnace Fan Blower - 1/2 HP 

800 

1300 

Kitchen 

 

 

Microwave Oven - 1000 Watt 

1000 

Coffee Maker 

1500 

Electric Stove - Single Element 

1500 

Hot Plate 

2500 

Family Room 

 

 

DVD/CD Player 

100 

VCR 

100 

Stereo Receiver 

450 

Color Television - 27” 

500 

Personal Computer w/17” monitor 

800 

Other 

 

 

Security System 

180 

AM/FM Clock Radio 

300 

Garage Door Opener - 1/2 HP 

480 

520 

Electric Water Heater - 40 Gallon 

4000 

DIY/Job Site 

 

 

Quartz Halogen Work Light 

1000 

Airless Sprayer - 1/3 HP 

600 

1200 

Reciprocating Saw 

960 

960 

Electric Drill - 1/2 HP 

1000 

1000 

Circular Saw - 7 1/4” 

1500 

1500 

Miter Saw - 10” 

1800 

1800 

Table Planer - 6” 

1800 

1800 

Table Saw/Radial Arm Saw - 10” 

2000 

2000 

Air Compressor - 1-1/2 HP 

2500 

2500 

Figure 9 - Wattage Reference Chart

Содержание 30242

Страница 1: ...4115 M F 8 5 CT web BRIGGSandSTRATTON COM Before using this product read this manual and follow all Safety Rules and Operating Instructions WARNING Antes de utilizar el producto lea este manual y sig...

Страница 2: ...to the engine owner s manual SAFETY RULES This is the safety alert symbol It is used to alert you to potential personal injury hazards Obey all safety messages that follow this symbol to avoid possib...

Страница 3: ...TING EQUIPMENT Ensure spark plug muffler fuel cap and air cleaner are in place DO NOT crank engine with spark plug removed WHEN OPERATING EQUIPMENT Do not tip engine or equipment at angle which causes...

Страница 4: ...an occur on contact Exhaust heat gases can ignite combustibles structures or damage fuel tank causing a fire WARNING When using generator for backup power notify utility company Use approved transfer...

Страница 5: ...UTION Use generator only for intended uses If you have questions about intended use ask dealer or call 1 800 743 4115 Operate generator only on level surfaces DO NOT expose generator to excessive mois...

Страница 6: ...of seven 7 U S gallons Grounding Fastener Consult your local agency having jurisdiction for grounding requirements in your area Oil Fill Cap Dipstick Add engine oil here Recoil starter Used to start t...

Страница 7: ...4115 Main unit Engine oil Operator s manual Engine operator s manual Battery float charger Wheel kit ELECTRIC START Your unit is equipped with electric start capability but can be started manually If...

Страница 8: ...peat step 3 thru 5 to secure second wheel 7 Tip generator so that engine side is down 8 Attach the vibration mounts to the support leg with 1 4 20 x 1 capscrews and 1 4 20 lock nuts 9 Remove existing...

Страница 9: ...nstall fuel cap and let any spilled fuel evaporate before starting engine High Altitude At higher altitudes over 5 000 feet 85 octane 85 AKI 89 RON gasoline is recommended High altitude use may requir...

Страница 10: ...t away from any windows doors ventilation intakes or other openings that can allow exhaust gas to collect in a confined area Figure 4 Prevailing winds and air currents should be taken into considerati...

Страница 11: ...e See Don t Overload Generator Start generator and let engine stabilize before connecting electrical loads Connect electrical loads in OFF position then turn ON for operation Turn electrical loads OFF...

Страница 12: ...requiring up to 2 400 watts 2 4 kW at 20 Amps of current Use cord sets that are rated for 125 Volt AC loads at 20 Amps or greater BATTERY CHARGER Use battery float charger jack to keep the starting ba...

Страница 13: ...r output to stabilize engine runs smoothly and attached device operates properly 4 Plug in and turn on the next load 5 Again permit the generator to stabilize 6 Repeat steps 4 and 5 for each additiona...

Страница 14: ...h cooling air slots some of the water will be retained in voids and cracks of the rotor and stator winding insulation Water and dirt buildup on the generator internal windings will eventually decrease...

Страница 15: ...ainer Then run engine until it stops from lack of fuel When fuel stabilizers are used according to their instructions there is no need to drain the gasoline from the engine prior to storage Use Briggs...

Страница 16: ...ion Generator runs good at no load but bogs down when loads are connected 1 Short circuit in a connected load 2 Generator is overloaded 3 Shorted generator circuit 1 Disconnect shorted electrical load...

Страница 17: ...d apologize to you for being inconvenienced Any Authorized Service Dealer may perform warranty repairs Most warranty repairs are handled routinely but sometimes requests for warranty service may not b...

Страница 18: ...ental y el Consejo de recursos de aire de California Para mayor informaci n acerca de la garant a consulte con el manual del operario del motor REGLAS DE SEGURIDAD ste es el s mbolo de alerta de segur...

Страница 19: ...ertas pilotos calor y otras fuentes de ignici n NO encienda un cigarrillo o fume CUANDO PONGA EN FUNCIONAMIENTO EL EQUIPO Compruebe que la buj a el silenciador el tap n del dep sito de combustible y e...

Страница 20: ...pre desconecte el alambre de la buj a y col quelo donde no pueda entrar en contacto con la buj a CUANDO PRUEBE LA BUJ A DEL MOTOR Utilice un comprobador de buj as homologado NO comprueba la chispa sin...

Страница 21: ...motor en funcionamiento Palanca del Cebador Usada cuando se est dando arranque a un motor fr o Silenciador Apagachispas El silenciador disminuye el ruido del motor y est equipado con una pantalla apag...

Страница 22: ...a generadores al 1 800 743 4115 Unidad Principal Aceite del Motor Manual del Operario Manual del Operario del Motor Corcel de Bater a Juego de Ruedas ARRANQUE EL CTRICO El arranque del generador se pu...

Страница 23: ...que el lado del motor quede abajo 8 Fije los bloques amortiguadores de vibraciones a la pata de apoyo con tornillos de cabeza 1 4 20 x 1 y tuercas 1 4 20 9 Extraiga los tornillos y las tuercas del blo...

Страница 24: ...e de combustible y la espera para alg n combustible rociado para evaporar Gran altitud A grandes altitudes por encima de 1 500 m 5 000 pies se recomienda utilizar gasolina de 85 octanos 85 AKI 89 RON...

Страница 25: ...arse Figura 13 Tenga en cuenta los vientos y las corriente de aire preponderantes cuando elija la ubicaci n del generador Cuando use un generador como poder de energ a auxiliar notifique a la compa a...

Страница 26: ...gas el ctricas Conecte las cargas el ctricas en la posici n de apagado OFF luego encienda ON para su operaci n Apague OFF las cargas el ctricas y descon ctelas del generador antes de parar el generado...

Страница 27: ...gas de 125 Voltios AC a 20 Amps o mayores CARGADOR DE BATER A Utilice el enchufe hembra del cargador de flotaci n carga lenta y continua de la bater a para mantener la bater a de arranque cargada y pr...

Страница 28: ...aparato conectado al mismo trabaja adecuadamente 4 Conecte y encienda la pr xima carga 5 De nuevo permita que el generador se estabilice 6 Repita los pasos 4 y 5 para cada carga adicional que usted te...

Страница 29: ...gua podr a introducirse en el sistema de combustible del motor y causar problemas Adem s si el agua se introduce al generador a trav s de las ranuras para aire de enfriamiento algo del agua quedar ret...

Страница 30: ...amente el motor utilizando un contenedor homologado A continuaci n deje funcionar el motor hasta que se agote el combustible Si se utiliza un estabilizador de combustible siguiendo correctamente las i...

Страница 31: ...in carga pero funciona mal cuando se le contectan cargas 1 Corto circuito en una de las cargas conectadas 2 El generador est sobrecarga 3 Circuito del generador en corto 1 Desconecte la carga el ctric...

Страница 32: ...itarios destinados al mantenimiento de las constantes vitales Esta garant a excluye los fallos debidos a hechos fortuitos y a otros acontecimientos de fuerza mayor que escapan al control del fabricant...