background image

2000W Generator

2

TABLE OF CONTENTS

Safety Rules. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4
Know Your Generator . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Assembly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-7
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-13
Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14-17
Storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20-21
Emmision Control Warranty. . . . . . . . . . . . . . . . . . . . . . . 22
Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23

EQUIPMENT

DESCRIPTION

Read this manual carefully and become familiar
with your generator. Know its applications, its
limitations and any hazards involved.

This generator is an engine–driven, revolving field,
alternating current (AC) generator. It was designed to
supply electrical power for operating compatible electrical
lighting, appliances, tools and motor loads. The generator’s
revolving field is driven at about 3,600 rpm by a single-
cylinder engine.

CAUTION!

DO NOT exceed the generator’s

wattage/amperage capacity. See “Don’t Overload the
Generator”.

Every effort has been made to ensure that information in
this manual is accurate and current. However, we reserve
the right to change, alter or otherwise improve the
product and this document at any time without prior
notice.

The Emission Control System for this generator is
warranted for standards set by the Environmental
Protection Agency.

SAFETY RULES

This is the safety alert symbol. It is used to
alert you to potential personal injury
hazards. Obey all safety messages that follow
this symbol to avoid possible injury or death.

The safety alert symbol (

) is used with a signal word

(DANGER, CAUTION, WARNING), a pictorial and/or a
safety message to alert you to hazards. DANGER
indicates a hazard which, if not avoided, will result in death
or serious injury. WARNING indicates a hazard which, if
not avoided, could result in death or serious injury.
CAUTION indicates a hazard which, if not avoided, might
result in minor or moderate injury. CAUTION, when
used without the alert symbol, indicates a situation that
could result in equipment damage. Follow safety messages
to avoid or reduce the risk of injury or death.

Hazard Symbols and Meanings

The engine exhaust from this product contains
chemicals known to the State of California to cause
cancer, birth defects, or other reproductive harm.

WARNING

Copyright © 2005 Briggs & Stratton Power Products
Group, LLC.  All rights reserved.  No part of this material
may be reproduced or transmitted in any form by any
means without the express written permission of Briggs &
Stratton Power Products Group, LLC.

Fire

Explosion

Toxic Fumes

Kickback

Electrocution

Electrical Shock

Explosive Pressure

Chemical Burn

Hot Surface

Содержание 30239

Страница 1: ...lez Ligne d assistance de G n rateur Llame L nea Directa del Generador 1 800 743 4115 M F 8 5 CT web www briggsandstratton com Before using this product read this manual and follow all Safety Rules an...

Страница 2: ...TY RULES This is the safety alert symbol It is used to alert you to potential personal injury hazards Obey all safety messages that follow this symbol to avoid possible injury or death The safety aler...

Страница 3: ...odily injury and or property damage WARNING WHEN ADDING OR DRAINING FUEL Turn generator OFF and let it cool at least 2 minutes before removing fuel cap Loosen cap slowly to relieve pressure in tank Fi...

Страница 4: ...R MAKING REPAIRS TO YOUR GENERATOR Disconnect the spark plug wire from the spark plug and place the wire where it cannot contact spark plug WHEN TESTING FOR ENGINE SPARK Use approved spark plug tester...

Страница 5: ...ssistance Engine ON OFF Switch Used to stop a running engine Fuel Shut Off Valve Use this valve to turn the fuel supply on and off Fuel Tank Capacity of 1 32 U S gallons 5 0 liters of fuel Grounding L...

Страница 6: ...gned to greatly improve the portability of your generator it is not intended for over the road use You will need a needle nose pliers to install this kit Refer to Figure 1 and install the wheel kit as...

Страница 7: ...2 Clean area around fuel fill cap remove cap 3 Slowly add regular unleaded fuel to fuel tank Be careful not to overfill Allow about 1 5 of tank space for fuel expansion as shown in Figure 3 NOTE Occa...

Страница 8: ...e generator in a well ventilated area which will allow for removal of deadly exhaust gas DO NOT place generator where exhaust gas could accumulate and enter inside or be drawn into a potentially occup...

Страница 9: ...e and servicing In the State of California a spark arrester is required by law Section 4442 of the California Public Resources Code Other states may have similar laws Federal laws apply on federal lan...

Страница 10: ...tem shuts down the engine add engine oil Charging a Battery Your generator has the capability of recharging a discharged 12 Volt automotive or utility style storage battery DO NOT use the unit to char...

Страница 11: ...arge a battery EXTENSION CORDS Use only high quality well insulated extension cords with the generator s 120 Volt electrical receptacles Check the ratings of all extension cords before you use them Su...

Страница 12: ...nt icing problem 10 Start and run engine outdoors 11 Keep exhaust gas from entering a confined area through windows doors ventilation intakes or other openings 12 DO NOT enclose generator any more tha...

Страница 13: ...in and turn on the first load preferably the largest load you have 3 Permit the generator output to stabilize engine runs smoothly and attached device operates properly 4 Plug in and turn on the next...

Страница 14: ...power This difference is due to a variety of factors including but not limited to the following differences in altitude temperature barometric pressure humidity fuel engine lubrication maximum govern...

Страница 15: ...iness of the generator frequently and clean when dust dirt oil moisture or other foreign substances are visible on its exterior surface NOTE DO NOT use a garden hose to clean generator Water can enter...

Страница 16: ...d tighten securely 8 Wipe up any spilled oil 9 Reconnect spark plug wire to spark plug KEEP OUT OF REACH OF CHILDREN DON T POLLUTE CONSERVE RESOURCES RETURN USED OIL TO COLLECTION CENTERS Clean Replac...

Страница 17: ...ver screws Clean Spark Arrester Screen The engine muffler is equipped with a removable spark arrester screen Inspect and clean the screen every 10 hours of operation or every 3 months whichever comes...

Страница 18: ...slowly to distribute oil Generator 1 Clean generator as outlined in Generator Cleaning 2 Check that cooling air slots and openings on generator are open and unobstructed Other Storage Tips 1 DO NOT st...

Страница 19: ...t of gasoline 5 Stale gasoline 6 Spark plug wire not connected to spark plug 7 Bad spark plug 8 Water in gasoline 9 Flooded 10 Excessively rich fuel mixture 11 Intake valve stuck open or closed 12 Eng...