5.

Check electrode gap with wire feeler gauge and set
spark plug gap to 0.030 inch (0.76 mm) if necessary
(Figure 15).

6.

Reinstall spark plug.

7.

Reconnect spark plug wire to spark plug.

Service Air Cleaner

Your engine will not run properly and may be damaged if
you run it using a dirty air cleaner.

Check the air cleaner every use and clean or replace the
air cleaner every 25 hours of operation or yearly,
whichever comes first. Clean or replace more often if
operating under dusty or dirty conditions.

To clean or replace air cleaner:

1.

Loosen air cleaner cover screws and remove cover.

2.

Remove the foam air cleaner and retainer.

3.

Wipe clean inside of air cleaner housing and cover
thoroughly.

4.

Wash air cleaner in a solution of household detergent
and warm water, then rinse thoroughly. Squeeze dry in
a clean cloth.

5.

Saturate air cleaner in clean engine oil and squeeze in a
clean, absorbent cloth to remove all excess oil. DO
NOT twist.

IMPORTANT: The engine will smoke during initial start-
up if too much oil is left in the air cleaner.

NOTE: If you need to order a new air cleaner, please call
1-800-743-4115.

6.

Reinstall the retainer, air cleaner and cover. Tighten
the air cleaner cover screws.

Clean Spark Arrester Screen

The engine muffler is equipped with a removable spark
arrester screen. Inspect and clean the screen every
10 hours of operation or every 3 months, whichever comes
first, as shown in Figure 16:

1.

Loosen screw on muffler tail pipe and remove spark
arrester screen.

2.

Use a brass or stiff-bristle brush to remove carbon
deposits from spark arrester surface.

3.

Inspect spark arrester for breaks or tears and replace
if necessary.

NOTE: If you need to order a new spark arrester, please
call 1-800-743-4115.

4.

Install clean screen in reverse order of removal.

NOTE: If you use your generator on any forest-covered,
brush-covered or grass-covered unimproved land, it must
have a spark arrester installed. The spark arrester must be
maintained in good condition by the owner/operator.

Air Cooling System

Over time debris may accumulate in cylinder cooling fins
and cannot be observed without partial engine disassembly.
For this reason, we recommend you have an authorized
Briggs and Stratton Power Products service dealer clean
the cooling system (Figure 17) per recommended intervals
(see “Maintenance Schedule” on page 15). Equally
important is to keep top of engine free from debris. See
“Generator Cleaning”.

Figure 15 — Service Spark Plug

Spark Arrester

Screen

Muffler Tail Pipe

Spark Arrester

Attachment Screw

Figure 16 – Service Spark Arrester Screen

Figure 17 — Air Cooling System

Содержание 30239

Страница 1: ...lez Ligne d assistance de G n rateur Llame L nea Directa del Generador 1 800 743 4115 M F 8 5 CT web www briggsandstratton com Before using this product read this manual and follow all Safety Rules an...

Страница 2: ...TY RULES This is the safety alert symbol It is used to alert you to potential personal injury hazards Obey all safety messages that follow this symbol to avoid possible injury or death The safety aler...

Страница 3: ...odily injury and or property damage WARNING WHEN ADDING OR DRAINING FUEL Turn generator OFF and let it cool at least 2 minutes before removing fuel cap Loosen cap slowly to relieve pressure in tank Fi...

Страница 4: ...R MAKING REPAIRS TO YOUR GENERATOR Disconnect the spark plug wire from the spark plug and place the wire where it cannot contact spark plug WHEN TESTING FOR ENGINE SPARK Use approved spark plug tester...

Страница 5: ...ssistance Engine ON OFF Switch Used to stop a running engine Fuel Shut Off Valve Use this valve to turn the fuel supply on and off Fuel Tank Capacity of 1 32 U S gallons 5 0 liters of fuel Grounding L...

Страница 6: ...gned to greatly improve the portability of your generator it is not intended for over the road use You will need a needle nose pliers to install this kit Refer to Figure 1 and install the wheel kit as...

Страница 7: ...2 Clean area around fuel fill cap remove cap 3 Slowly add regular unleaded fuel to fuel tank Be careful not to overfill Allow about 1 5 of tank space for fuel expansion as shown in Figure 3 NOTE Occa...

Страница 8: ...e generator in a well ventilated area which will allow for removal of deadly exhaust gas DO NOT place generator where exhaust gas could accumulate and enter inside or be drawn into a potentially occup...

Страница 9: ...e and servicing In the State of California a spark arrester is required by law Section 4442 of the California Public Resources Code Other states may have similar laws Federal laws apply on federal lan...

Страница 10: ...tem shuts down the engine add engine oil Charging a Battery Your generator has the capability of recharging a discharged 12 Volt automotive or utility style storage battery DO NOT use the unit to char...

Страница 11: ...arge a battery EXTENSION CORDS Use only high quality well insulated extension cords with the generator s 120 Volt electrical receptacles Check the ratings of all extension cords before you use them Su...

Страница 12: ...nt icing problem 10 Start and run engine outdoors 11 Keep exhaust gas from entering a confined area through windows doors ventilation intakes or other openings 12 DO NOT enclose generator any more tha...

Страница 13: ...in and turn on the first load preferably the largest load you have 3 Permit the generator output to stabilize engine runs smoothly and attached device operates properly 4 Plug in and turn on the next...

Страница 14: ...power This difference is due to a variety of factors including but not limited to the following differences in altitude temperature barometric pressure humidity fuel engine lubrication maximum govern...

Страница 15: ...iness of the generator frequently and clean when dust dirt oil moisture or other foreign substances are visible on its exterior surface NOTE DO NOT use a garden hose to clean generator Water can enter...

Страница 16: ...d tighten securely 8 Wipe up any spilled oil 9 Reconnect spark plug wire to spark plug KEEP OUT OF REACH OF CHILDREN DON T POLLUTE CONSERVE RESOURCES RETURN USED OIL TO COLLECTION CENTERS Clean Replac...

Страница 17: ...ver screws Clean Spark Arrester Screen The engine muffler is equipped with a removable spark arrester screen Inspect and clean the screen every 10 hours of operation or every 3 months whichever comes...

Страница 18: ...slowly to distribute oil Generator 1 Clean generator as outlined in Generator Cleaning 2 Check that cooling air slots and openings on generator are open and unobstructed Other Storage Tips 1 DO NOT st...

Страница 19: ...t of gasoline 5 Stale gasoline 6 Spark plug wire not connected to spark plug 7 Bad spark plug 8 Water in gasoline 9 Flooded 10 Excessively rich fuel mixture 11 Intake valve stuck open or closed 12 Eng...

Страница 20: ...2000W Generator 20 NOTES...

Страница 21: ...2000W Generator 21 NOTES...

Страница 22: ...s you should contact a Briggs and Stratton Power Products Service Representative at 1 800 743 4115 The emission warranty is a defects warranty Defects are judged on normal engine performance The warra...

Страница 23: ...ctric powered pressure washers used for commercial purposes are not warranted NO WARRANTY REGISTRATION IS NECESSARY TO OBTAIN WARRANTY ON BRIGGS STRATTON PRODUCTS SAVE YOUR PROOF OF PURCHASE RECEIPT I...