5
BSPP Generator
KNOW YOUR GENERATOR
Read this owner’s manual and safety rules before operating your generator.
Compare the illustrations with your generator, to familiarize yourself with the locations of various controls and
adjustments. Save this manual for future reference.
12 Volt DC Receptacle — Use this receptacle with battery
charge cables to charge a 12 Volt battery.
120 Volt AC, 20 Amp Duplex Receptacles — May be used to
supply electrical power for the operation of 120 Volt AC, 20 Amp,
single phase, 60 Hz electrical lighting, appliance, tool and motor loads.
120 Volt AC, 30 Amp Locking Receptacle — May be used to
supply electrical power for the operation of 120 Volt AC, 30 Amp,
single phase, 60 Hz electrical lighting, appliance, tool and motor
loads.
120/240 Volt AC, 30 Amp Locking Receptacle — May be
used to supply electrical power for the operation of 120 and/or
240 Volt AC, 30 Amp, single phase, 60 Hz electrical lighting,
appliance, tool and motor loads.
Air Cleaner — Uses a dry type filter element and foam
pre–cleaner to limit the amount of dirt and dust sucked into the
engine.
Choke Lever — Used when starting a cold engine.
Circuit Breakers (AC) — Push to reset circuit breakers are
provided to protect the generator against electrical overload.
Data Tag – Provides model, revision and serial number of
generator. Please have these readily available if calling for
assistance.
Fuel Tank — Capacity of seven (7) U.S. gallons.
GFCI Circuit Breaker — A GFCI circuit breaker is provided to
protect against electrical ground fault and protect the generator
against electrical overload.
Grounding Fastener — If required, please consult a qualified
electrician, electrical inspector, or local agency having jurisdiction.
Hour Meter — Displays and records how many hours your
generator has run (up to 9,999.9).
Idle Control Switch — The idle control runs the engine at
normal (high) speeds when there is a load present and runs the
engine at idle (low) speeds when a load is not present.
Ignition Switch — Push to start and stop the engine.
Oil Fill Cap — Add oil to engine here.
Spark Arrester Muffler — Exhaust muffler lowers engine noise
and is equipped with a spark arrester screen.
Choke Lever
120 Volt AC, 20 Amp
Duplex Receptacles
12 Volt DC
Receptacle
Spark Arrester Muffler
Ignition Switch
Grounding
Fastener
Air Cleaner
Fuel Tank
Oil Fill Cap
Data Tag
Hour Meter
Idle Control Switch
GFCI Circuit Breaker
Circuit Breakers (AC)
120/240 Volt AC, 30 Amp
Locking Receptacle
120 Volt AC, 30 Amp
Locking Receptacle
Содержание 1934
Страница 18: ...18 BSPP Generator NOTES ...
Страница 36: ...BSPP Génératrice 36 REMARQUES ...
Страница 54: ...54 BSPP Generador NOTAS ...
Страница 55: ...55 BSPP Generador NOTAS ...