Not for
Reproduction
22 BRIGGSandSTRATTON.COM
Storage
The generator should be started at least once every
seven days and allowed to run at least 30 minutes. If
this cannot be done and you must store the unit for
more than 30 days, use the following guidelines to
prepare it for storage.
Generator Storage
1. Clean the generator as outlined in
Cleaning
in the
Maintenance
section.
2. Check that cooling air slots and openings on
generator are open and unobstructed.
Long Term Storage Instructions
Fuel can become stale when stored over 30 days.
Stale fuel causes acid and gum deposits to form in the
fuel system or on essential carburetor parts. To keep
fuel fresh, use Briggs & Stratton® Advanced Formula
Fuel Treatment & Stabilizer, available wherever Briggs
& Stratton genuine service parts are sold.
There is no need to drain gasoline from the engine
if a fuel stabilizer is added according to instructions.
Run the engine for 2 minutes to circulate the stabilizer
throughout the fuel system before storage.
If gasoline in the engine has not been treated with a
fuel stabilizer, it must be drained into an approved
container. Run the engine until it stops from lack
of fuel. The use of a fuel stabilizer in the storage
container is recommended to maintain freshness.
Change Oil
While engine is still warm, drain oil from crankcase.
Refill with recommended grade. See
Changing Engine
Oil
in
Engine Maintenance
.
Other Storage Tips
1. DO NOT store fuel from one season to another
unless it has been treated as described in
Long
Term Storage Instructions
.
2. Replace fuel can if it starts to rust. Contaminated
fuel will cause engine problems.
3. If possible, store unit indoors and cover it to give
protection from dust and dirt.
4. Cover unit with a suitable protective cover that
does not retain moisture.
5. Store generator in clean, dry area.
WARNING
Fuel and its vapors are extremely
flammable and explosive which could
cause burns, fire or explosion
resulting in death or serious injury.
WHEN STORING FUEL OR EQUIPMENT WITH FUEL IN
TANK
• Store away from furnaces, stoves, water heaters, clothes
dryers or other appliances that have pilot light or other
ignition source because they could ignite fuel vapors.
WHEN DRAINING FUEL
• Turn generator engine OFF and let it cool at least 2
minutes before removing fuel cap. Loosen cap slowly to
relieve pressure in tank.
• Drain fuel tank outdoors.
• Keep fuel away from sparks, open flames, pilot lights,
heat, and other ignition sources.
• Check fuel lines, tank, cap and fittings frequently for
cracks or leaks. Replace if necessary.
• DO NOT light a cigarette or smoke.
WARNING
Storage covers could cause a fire
resulting in death or serious injury.
• DO NOT place a storage cover over a hot generator.
• Let equipment cool for a sufficient time before placing the
cover on the equipment.