background image

200

-

0057

-

08

 

 

June 07 2019

 

57-DVRS50N 

Direct Vent Gas  

Fireplace Heater 

U

SERS’  

I

NSTALLATION 

O

PERATION  and 

M

AINTENANCE 

M

ANUAL 

 INSTALLER: 

Leave this manual with the appliance

.

 

CONSUMER: 

Retain this manual for future reference.

 

SERIAL NUMBERS  510083 AND HIGHER 

This appliance may be installed in an aftermarket 

permanently located, manufactured home (USA 

only) or mobile home, where not prohibited by 

local codes.

 

This appliance is only for use with the type 

 

of gas indicated on the rating plate. This 

appliance is not convertible for use with other 

gases, unless a certified kit is used.  

 

-

 Do not store or use gasoline or other flammable vapors or

 

liquids in the vicinity of this or any other appliance.

 

 
-

 WHAT TO DO IF YOU SMELL GAS:

 

 

• 

Do not try to light any appliance

 

 

• 

Do not touch any electrical switch; do not use any

 

 

phone in your building

 

 

• 

Leave the building immediately

 

 

• 

Immediately call your gas supplier from a 

 

 

neighbor's phone. Follow the gas suppliers 

 

 

instructions

 

 

• 

If you can not reach your gas supplier, call the fire

 

 

department

 

-

 Installation and service must be performed by a qualified

 

installer, service agency or the gas supplier.

 

WARNING:

 

If the information in this manual is 

not followed exactly, a fire or explosion may 

result causing property damage, personal 

injury or loss of life.

 

Archgard Fireplace Products

 

7116 Beatty Dr

 

Mission, BC V2V 6B4

 

Canada

 

Gas Fireplace Efficiency Rating

 

 

72.74%

 

 

Based on CSA P.4.1

-

15

 

Содержание 510083

Страница 1: ...e or other flammable vapors or liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any ph...

Страница 2: ...llation 19 Burner media Door Screen and Surround Installation 20 22 Checking Inlet Outlet pressures 23 Final Installation Check and Initial Operation 24 Lighting Instructions on Rating Plate 25 First...

Страница 3: ...ns that it is less expensive to operate Adjustable Flame The flame aesthetics and heat output can be adjusted to suit your heating needs Solid Construction The 57 DVRS50N is constructed mainly of 14 a...

Страница 4: ...57 DVRS50N 3 RATING PLATE...

Страница 5: ...Terminations installed and sealed in compliance with local building code Direct vent termination is highest point in vent assembly Wiring Electrical YES IF NO WHY NOT Connected to household 110 120v...

Страница 6: ...quids near the appliance Clothing or other flammable material should not be placed on or near the appliance WARNING Do not operate appliance with the glass front removed cracked or broken Removal of t...

Страница 7: ...he US and in Canada the current Canadian Electrical Code CSA C22 1 We recommend that our gas hearth products be installed and serviced by professionals who are certified in the U S by the National Fir...

Страница 8: ...57 DVRS50N 7 APPLIANCE DIMENSIONS Surround Removed Surround Attached...

Страница 9: ...the requirements for framing for the model 57 DVRS50N Note Framing should be constructed as required by local building codes 2 x 6 Framing opening in framing should be minimum of 66 50 W x 42 00 H Fig...

Страница 10: ...2 50 Vent side bottom 1 25 Front 48 1220 Room Ceiling From top of door 30 762 Minimum measurements below are from the edge of door unless otherwise noted Clearance to Combustibles Clearance to combust...

Страница 11: ...L Stand off The 999 DV 8HTCLT termination allows the horizontal run to a maximum of 32 Use when connecting to a flexible vent system Maximum 6 Horizontal run when using the basic 999 DV 8HTCL Terminat...

Страница 12: ...facing into the room Install the wall thimble as shown below and seal it and the edges of the insulation board with a good quality silicone sealant to prevent cold drafts exterior wall only Figure 7 S...

Страница 13: ...nd the termination Installed fireplace with stand offs Figure 11 Figure 12 Figure 10 N O T E For installations straight off the back of the 57 DVRS50N the Archgard 999 DV 8HTCL termination is required...

Страница 14: ...through The following vent systems are certified for use with the model 57 DVRS50N If for any reason the vent pipe is disconnected it must be correctly resealed Fig 14 A Manufacturer Termination Adapt...

Страница 15: ...screws through the holes in the corners Complete the termination installation and apply a bead of mastic around the outer edge of the vinyl standoff With the termination installed you can now connect...

Страница 16: ...to an inside corner 12 30 cm Note Clear ances are to be in accordance with local installation codes and the requirements of the gas supplier G Do not install above a meter regulator assembly within 3...

Страница 17: ...flat ceiling install a Box Wall thimble Cut a 10 square hole and frame as shown in the diagram opposite Ensure all pipe sections are fully twist locked NOTE ALWAYS CHECK YOUR LOCAL CODES BEFORE INSTA...

Страница 18: ...ation at point A you use 2 90 elbows you would be required to reduce the maxi mum horizontal from16 to 15 If 3 90 elbows were used to reach point A the maximum horizontal would be reduced from 16 to 1...

Страница 19: ...warranty Natural Gas Pressure Settings The inlet supply or line pressure must be a minimum of 5 0 W C 1 2 kPa and a maximum of 14 0 W C 3 5 kPa The orifices are a 35 DMS 2 79 mm drill size for the ce...

Страница 20: ...il they touch the center panel Rear Panel Installation Instructions Side Panel Baffle Installation Instructions Set the right and left side panels by inserting the tabs into the slot of the support pl...

Страница 21: ...To install the logs follow the directions below The glass media has been removed in the pictures for clarity of port position relative to the logs Step 1 Place the first log on the far left of the fir...

Страница 22: ...d over the tabs on the bottom of the door and release as shown below Door Installation In the event your glass cracks or breaks replace the original door assembly with Archgard replacement door assemb...

Страница 23: ...ocated on the corners at the bottom of the screen Place bottom tabs on the inside edge of door frame Slightly twist top part of screen frame to position top mounting tabs inside upper edge of door fra...

Страница 24: ...ee right The surround is held in place by clips buttons two at the top two at the bottom Line up the clips with the fireplace and push until it locks in You can adjust the surround by moving the brack...

Страница 25: ...are within specs as shown on the appliance rating plate 6 Be sure to tighten the set screw inside the tap after you have completed taking pressure readings 7 Check for leaks CHECKING INLET AND OUTLET...

Страница 26: ...nit with the customer the installer must ensure that the appliance is firing correctly and that the electrical system is in working order This will include 1 Perform leak tests of supply line gas cont...

Страница 27: ...57 DVRS50N 26 LIGHTING INSTRUCTIONS ON RATING PLATE...

Страница 28: ...t cover of this manual 3 Do not use this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control syst...

Страница 29: ...57 DVRS50N 28 REMOTE CONTROL SETUP AND OPERATION future option SIMPLE INSTALLATION Optional handheld remote...

Страница 30: ...R MAINTENANCE OF THE RECEIVER DEVICE TURN OFF MAIN GAS SUPPLY TO THE APPLIANCE PRIOR TO REMOVING OR REINSERTING THE BAT TERIES IN CASE OF REMOTE CONTROL MALFUNCTION TURN OFF THE FIREPLACE BY REMOVING...

Страница 31: ...57 DVRS50N 30 REMOTE CONTROL SETUP AND OPERATION cont...

Страница 32: ...57 DVRS50N 31 REMOTE CONTROL SETUP AND OPERATION cont...

Страница 33: ...57 DVRS50N 32 REMOTE CONTROL SETUP AND OPERATION cont...

Страница 34: ...ROL SETUP AND OPERATION cont The unit is shipped from the factory with the ability for IPI CPI selection active To disable the Continuous Pilot selection ability cut one of the wires blue or white sho...

Страница 35: ...57 DVRS50N 34 REMOTE CONTROL SETUP AND OPERATION cont...

Страница 36: ...FICE CHANGE This fireplace uses three orifices The two 2 outside burner orifices and the center burner orifice Care must be taken not to install the center orifice in an outside burner position This w...

Страница 37: ...t obstructed and it is recommended you use a vacuum cleaner to clean off any dust or lint Vacuum and clean any lint accumulations or debris in the firebox on the burners on the pilot at the primary ai...

Страница 38: ...57 DVRS50N 37 CONVERSION KIT INSTRUCTIONS con t Step 7 Valve Conversion...

Страница 39: ...t operation Reinstall door assembly and surround Run through a complete firing cycle to confirm correct operation KIT NUMBERS 57 CKELP for LP gas and 57 CKENG for Natural Gas KIT INCLUDES 1 Gas conver...

Страница 40: ...57 DVRS50N 39 WIRING SCHEMATIC Figure 25...

Страница 41: ...pack of 5 Fuse for control module 308 6017 SIT 885 VALVE W STEP MOTOR Main gas valve 308 0123 PILOT ASSEMBLY PSE pilot assembly 857 0014 REPLACEMENT SPLIT FLOW KIT units prior to S N 510071 Split flow...

Страница 42: ...ifferent gauges of steel used to manufacture your fireplace will expand and contract at different rates when your fireplace is on and will continued as your fireplace completes its heating function Yo...

Страница 43: ...p please have the following information Model of your Fireplace Serial Number Place of Purchase Date of Purchase Problem Description NOTE Warranty may be void if work is carried out by an unqualified...

Страница 44: ...57 DVRS50N 43 NOTES...

Страница 45: ...57 DVRS50N 44 NOTES...

Страница 46: ...57 DVRS50N 45 NOTES...

Страница 47: ...Name Address City State Prov ZIP Phone _____ Why did you choose this product Thank you for purchasing our product and filling out this warranty card mm did yyyy POSTAGE FOLD DOWN AT LINE FOLD DOWN AT...

Страница 48: ...ARCHGARD INDUSTRIES 7116 Beatty Drive Mission B C V2V 6B4 Canada Website www archgard com...

Отзывы: