35-DVRS31N
22
1. Remove the surround.
2. The pressure test taps are located on the valve. The taps are located in the gas valve front face.
The inlet is marked ‘
IN
’
and the outlet is marked ‘
OUT
’.
See Figure below.
3. Loosen the set screw inside the tap with a screwdriver.
4. Connect a 1/4” (6 mm) rubber tube to the tap post and a manometer.
5. Verify that the readings obtained are within specs (as shown on the appliance rating plate)
6. Be sure to tighten the set screw inside the tap after you have finished taking pressure readings.
7. Check for leaks.
CHECKING INLET AND OUTLET GAS PRESSURE
CHECKING AND ADJUSTING PILOT
The flame should not have yellow tips but should engulf
the flame sensor and spark electrode. It can be adjusted
be turning the screw marked “pilot” on the control valve.
Sensor
Ignitor
The pilot flame should
have the characteristic as
shown in the illustration to
the right.
Fig. 22-B
Fig. 22-C
Outlet pressure tap
Stepper motor
Pilot connection
(orange)
Pilot flame adjustment
Inlet pressure tap
Main Valve Connection
(green)
Fig. 22-A