background image

200-0035 

 

June 2015 

35-DVRS31N-2 

Gas Fired Vented Room 

Heater (Direct Vent) 

U

SERS’  

I

NSTALLATION 

O

PERATION  and 

M

AINTENANCE 

M

ANUAL 

7116 Beatty Dr 
Mission, BC V2V 6B4 
Canada 

 INSTALLER: 

Leave this manual with the appliance

CONSUMER: 

Retain this manual for future reference.

 

Do not store or use gasoline or other flammable 

vapors and liquids in the vicinity of this or any other 

appliance. 
 

WHAT TO DO IF YOU SMELL GAS:

 

 

Do not try to light any appliance. 

 

Do not touch any electrical switch; do not use 
any phone in your building. 

 

Immediately call your gas supplier from a 
neighbor’s phone. Follow the gas supplier’s 
instructions. 

 

If you cannot reach your gas supplier, call the fire 

department. 

 
Installation and service must be performed by a 
qualified installer, service agency or the gas 
supplier. 

This appliance may be installed in an aftermarket 
permanently located, manufactured home (USA 
only) or mobile home, where not prohibited by 
local codes. 
This appliance is only for use with the type  
of gas indicated on the rating plate. This 
appliance is not convertible for use with other 
gases, unless a certified kit is used.   

*Conversion kit required for Propane use 

WARNING: 

If the information in this manual is 

not followed exactly, a fire or explosion may 

result causing property damage, personal 

injury or loss of life. 

Tested &  
listed by 

LABTEST Certification Inc 
Richmond, British Columbia 
ANSI Z21.88-2009/CSA 2.33-2009 

SERIAL NUMBERS  310618 AND HIGHER 

Содержание 35-DVRS31N-2

Страница 1: ...f you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier This appliance may be installed in...

Страница 2: ...ressures Adjusting Pilot and Convertible Pilot Orifice 22 Contemporary Panel part list Installation Instructions 23 24 Door Removal Surround Clip Installation Surround Installation Removal 25 Glass Be...

Страница 3: ...inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless upon inspection the inspector observes carbon monoxide detectors and signage installed in...

Страница 4: ...ent gas fireplace which means that it is less expensive to operate Adjustable Flame The flame aesthetics and heat output can be adjusted to suit the owner s liking and heating needs Solid Construction...

Страница 5: ...and at least annually by a professional service person More frequent cleaning may be required due to excessive lint from carpeting bedding materials etc It is imperative that the control compartments...

Страница 6: ...the Manufactured Home Construction and Safety Standard Title 24CFR Part 3280 or when such a standard is not applicable the Standard for manufactured Home Installations ANSI NCSBCS A225 1 or Standard f...

Страница 7: ...Test e selon les normes ANSI Z21 88 2009 CSA 2 33 2009 and CAN CGA 2 17 M91 VENTED GAS FIREPLACE HEATER NOT FOR USE WITH SOLID FUEL This vented gas fireplace heater is not for use with air filters Cer...

Страница 8: ...35 DVRS31N 8 APPLIANCE DIMENSIONS Surround Installed Surround Removed Fig 8 C Fig 8 A Fig 8 B Fig 8 D Fig 8 F Fig 8 E REAR FRONT LEFT RIGHT REAR FRONT LEFT RIGHT...

Страница 9: ...g in an exterior wall you must include the exterior wall insulation and termination kit Place insulation board with the foil facing in to the room as shown in figure 9 C Frame hole out opening and cut...

Страница 10: ...into the wall Caulk the vent collar and fire stop from the outside to prevent cold drafts Install the termination When installing the fireplace into the wall DO NOT flush the front of the unit with t...

Страница 11: ...are from the edge of door unless otherwise noted Clearance to Combustibles Clearance to combustibles Room floor must be maintained from the top surface of carpet flooring etc Nailing Flanges Install...

Страница 12: ...t using 2 ply aluminum flex a change to the 999 DV HTC is required The Brigantia 35 DVRS31N requires 120v for the operating system There is a factory installed electrical box to accommodate the connec...

Страница 13: ...terminal Attach the terminal to the exterior wall using four wood screws through the holes in the corner of the vent terminal Complete the terminal installation and apply a bead of mastic around the o...

Страница 14: ...NATION WILL CAUSE POOR COMBUSTION AND OR HIGH TEMPERTURES THAT MAY PRESENT A FIRE HAZARD WHEN HORIZONTAL VENTING 1 4 FT RISE IS REQUIRED SEE VENTING CHART FOR ACCEPTABLE VENTING CONFIGURATIONS Fire st...

Страница 15: ...The listed chimney vent systems use a twist lock connection Assemble the vent system using the desired combination of sections and elbows for your installation Make sure you fully insert and twist th...

Страница 16: ...9 23 cm Note Clearances are to be in accordance with local installation codes and the requirements of the gas supplier G Do not install above a meter regulator assembly within 3 feet 90 cm horizontall...

Страница 17: ...ations For vertical installations determine the length of vent pipe required by meas uring the distance from the appliance flue outlet to the ceiling the ceiling thickness the vertical rise in the att...

Страница 18: ...rotection Pitch Rise in ft Rise m 0 12 6 12 12 1ft 30m 7 12 9 12 18 1 5ft 46m 10 12 12 12 24 2ft 61m 13 12 16 12 36 3ft 91m 17 12 24 12 48 4ft 1 22m Fig 18 A When passing through a flat ceiling instal...

Страница 19: ...ted 3 Note if more than 1 90 elbow is used horizontally the maximum horizontal is reduced by 1ft Example B If to reach the desired termination at point B you use 2 90 elbows you would be required to r...

Страница 20: ...tivation from remote The SIT Control Module is powered by 120V with an internal transformer for the valve This is pre wired to the factory installed electrical box for the electrician Some jurisdictio...

Страница 21: ...s individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psig 3 5 kPa Failure to do so will damage the appliance s gas...

Страница 22: ...Be sure to tighten the set screw inside the tap after you have finished taking pressure readings 7 Check for leaks CHECKING INLET AND OUTLET GAS PRESSURE CHECKING AND ADJUSTING PILOT The flame should...

Страница 23: ...35 DVRS31N 23 Contemporary Panels ITEM NO PART NUMBER DESCRIPTION QTY 1 311 6351 FB REAR PANEL 1 2 311 6352 FB SIDE PANEL 2 L R 3 750 1015 BAFFLE 1 Fig 23 A PANELS DETAIL Fig 23 B 1 Back Side...

Страница 24: ...he right to make room for the side panel Install keyed side panel to the left side same as right side Remove burner cover and place to the side to be re installed at the end After the panels have been...

Страница 25: ...out to 30 degrees and lift upward to release the 2 latches at the top of the door CAUTION Beware the glass does not drop out Firmly grip the door and glass when removing door assembly Surround Clip Mo...

Страница 26: ...trol valve supply line from gas control valve and pilot assembly 2 Clocking the appliance to ensure the correct firing rate see page 9 of this manual 3 If required adjusting the primary air to burner...

Страница 27: ...35 DVRS31N 27...

Страница 28: ...35 DVRS31N 28 LIGHTING INSTRUCTIONS ON RATING PLATE...

Страница 29: ...nder water 4 This appliance is equipped with an ignition device which automatically lights the pilot and main burner The pilot and burner light automatically with the hand held remote or with the swit...

Страница 30: ...y A Mode Key is provided to index between the features and a Thermostat Key is used for on off or to index through the thermostat func tion Additionally a Key Lock function is provided A T T E N T I O...

Страница 31: ...DEVICES PLACING THE TRANSMITTER IN OR NEAR METAL ENCLOSURES MAY REDUCE THE SIGNAL RANGE HANDHELD REMOTE DISPLAY Not for use on this unit All the same functions of the Handheld Remote with the convenie...

Страница 32: ...me the Receiver will activate the appliance A single beep from the receiver will confirm reception of the command TURN OFF THE APPLIANCE With the system OFF press the ON OFF Key on the Transmitter The...

Страница 33: ...Arrow Key will increase the flame height each time it is pressed If the UP Arrow Key is pressed while the system is on but the flame is off the flame will activate in the high setting A single beep w...

Страница 34: ...l change to show that the room thermostat is ON and the set temperature is now active To adjust the temperature press the Up Down Arrow Keys until the desired temperature is displayed SMART THERMOSTAT...

Страница 35: ...I IPI selection REMOTE CONTROL SETUP AND OPERATION AUTOMATIC SAFETY SHUT OFF This system will execute an automatic turn OFF command after a 24hr continuous pilot flame ignition This allows the system...

Страница 36: ...l battery power is lost When the batteries are replaced this Icon will disappear REMOTE CONTROL SETUP AND OPERATION BACKUP BATTERY PACK used when electrical power is interrupted Red LED indicator on t...

Страница 37: ...S31N 37 SIT INTERMITTENT PILOT IGNITION SEQUENCE FLOWCHART Fig 36 A W A R N I N G If the appliance goes into a Lock out mode repeatedly please contact a Licensed Service Tech for Troubleshooting and S...

Страница 38: ...35 DVRS31N 38 SIT BURNER IGNITION SEQUENCE FLOWCHART Fig 37 A W A R N I N G If the appliance goes into a Lock out mode repeatedly please contact a Licensed Service Tech for Troubleshooting and Service...

Страница 39: ...ce batteries if depleted Use Battery Back up Remote not working properly Check Batteries replace if depleted Re sync Remote to module see initial set up Pilot is not on See pilot troubleshooting Remot...

Страница 40: ...extinguishes Confirm Glass Door frame is installed correctly Blocked Air intake Check venting Gas pressure too high Compensate for altitude if required Improper venting set up insufficient rise on ven...

Страница 41: ...seal is found to be defective replace and or reseal follow the instructions found in the venting instructions section Verify proper operation after servicing Clean and remove any lint accumulations or...

Страница 42: ...side propane with the hole in it is showing Tighten the pilot hood back up so that it is lined up with the two probes on both sides of the pilot assembly F O R Y O U R S A F E T Y SHUT OFF GAS SUPPLY...

Страница 43: ...on the gas and electrical supplies and check for leaks at all connections Turn on the fireplace so the burner is on Test inlet and outlet pressure Visually check pilot flame Flame should envelope top...

Страница 44: ...r EA 301 0068 Orifice Main Burner Orifice Drill to 35 DMS for Natural Gas EA Orifice Main Burner Orifice Drill to 52 DMS for LP Gas EA 308 0123 Pilot Assembly conv PSE IPI SIT Connections EA 835 0050...

Страница 45: ...d off A The different gauges of steel used to manufacture your fireplace will expand and contract at differ ent rates when your fireplace is on and will continued as your fireplace completes its heati...

Страница 46: ...35 DVRS31N 46 NOTES...

Страница 47: ...carried out by an unqualified person s Only original Brigantia parts may be used Please consult your Brigantia dealer or representative if in doubt about a replacement part s OBTAINING WARRANTY SERVI...

Страница 48: ...Name Address City State Prov ZIP Phone _____ Why did you choose this product Thank you for purchasing our product and filling out this warranty card mm dd yyyy POSTAGE FOLD DOWN AT LINE FOLD DOWN AT...

Страница 49: ...ARCHGARD FIREPLACES 7116 Beatty Drive Mission B C V2V 6B4 Canada Website www archgard com...

Отзывы: