background image

200

-

0324

-

07

 

 

July 11 2019

 

24-DVRS25NB-2 

24-DVRS25NBN-2 

Direct Vent Gas Fireplace 

Heater 

U

SERS’  

I

NSTALLATION 

O

PERATION  and 

M

AINTENANCE 

M

ANUAL 

 INSTALLER: 

Leave this manual with the appliance

.

 

CONSUMER: 

Retain this manual for future reference.

 

-

 Do not store or use gasoline or other flammable vapors or

 

liquids in the vicinity of this or any other appliance.

 

 
-

 WHAT TO DO IF YOU SMELL GAS:

 

 

• 

Do not try to light any appliance

 

 

• 

Do not touch any electrical switch; do not use any

 

 

phone in your building

 

 

• 

Leave the building immediately

 

 

• 

Immediately call your gas supplier from a 

 

 

neighbor's phone. Follow the gas suppliers 

 

 

instructions

 

 

• 

If you can not reach your gas supplier, call the fire

 

 

department

 

-

 Installation and service must be performed by a qualified

 

installer, service agency or the gas supplier.

 

This appliance may be installed in an aftermarket 

permanently located, manufactured home (USA 

only) or mobile home, where not prohibited by 

local codes.

 

This appliance is only for use with the type 

 

of gas indicated on the rating plate. This 

appliance is not convertible for use with other 

gases, unless a certified kit is used.  

 

WARNING:

 

If the information in this manual is 

not followed exactly, a fire or explosion may 

result causing property damage, personal 

injury or loss of life.

 

SERIAL NUMBERS  300308 AND HIGHER 

Gas Fireplace Efficiency Rating

 

 

74.96%

 

 

Based on CSA P.4.1

-

15

 

Archgard Fireplace Products

 

7116 Beatty Dr

 

Mission, BC V2V 6B4

 

Canada

 

Содержание 24-DVRS25NB-2

Страница 1: ...ions If you can not reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier This appliance may be instal...

Страница 2: ...gas pressures Adjusting Pilot and Convertible Pilot Orifice 20 Contemporary Panels 21 Component Removal Door Removal Surround Clip Installation 22 Safety Barrier Installation 23 Final Installation Ch...

Страница 3: ...e fireplace could become very cold to the touch Dynamic Start Advantage will solve most problems experienced by older IPI operated fireplaces Please complete and submit the warranty registration card...

Страница 4: ...24 DVRS25NB N 2 4 RATING PLATE...

Страница 5: ...run Terminations installed and sealed in compliance with local building code Direct vent termination is highest point in vent assembly Wiring Electrical YES IF NO WHY NOT Connected to household 110 12...

Страница 6: ...and liquids near the appliance Clothing or other flammable material should not be placed on or near the appliance WARNING Do not operate appliance with the glass front removed cracked or broken Remova...

Страница 7: ...ectrical code ANSI NFPA No 70 1987 in the US and in Canada the current Canadian Electrical Code CSA C22 1 We recommend that our gas hearth products be installed and serviced by professionals who are c...

Страница 8: ...24 DVRS25NB N 2 8 APPLIANCE DIMENSIONS Surround Installed Surround Removed...

Страница 9: ...1 2 wide x 39 1 2 high X 5 1 2 deep The bottom of the frame must be min 4 up from combustible floor Installation Instructions When installing on an exterior wall you must include the exterior wall in...

Страница 10: ...drafts See figure 4 Figure 4 Install the nailing flanges provide by screwing them to the side of the outer shell using the hole required for the facing material Then place the fireplace into the frame...

Страница 11: ...he 120V circuit must be electrically grounded in accordance with the local codes or in absence of local codes with the National Electrical Code ANSI NFPA 70 or the Canadian Electrical Code CSA C22 1 E...

Страница 12: ...om the edge of door unless otherwise noted Clearance to Combustibles Clearance to combustible floor must maintain clearances from the top surface of carpet flooring etc Nailing Flanges Install the nai...

Страница 13: ...y spaced around the pipe These indentations are designed to slide over the male section of the pipe and fully lock by a clockwise quarter turn Vent Restrictors Due to the extra flow produced by tall v...

Страница 14: ...standoff and the terminal Attach the terminal to the exterior wall using four wood screws through the holes in the corner of the vent terminal Complete the terminal installation and apply a bead of m...

Страница 15: ...iling joists roof rafters or other framing will obstruct the vent system You may have to use 45 elbows to navigate around any obstacles When passing through a flat ceiling install a Box Wall thimble C...

Страница 16: ...ide corner 9 23 cm Note Clear ances are to be in accordance with local installation codes and the requirements of the gas supplier G Do not install above a meter regulator assembly within 3 feet 90 cm...

Страница 17: ...izontal Use restrictor setting No 1 Example C 17ft vertical rise 1 90 elbow 5ft horizontal Use restrictor setting No 2 Maximum horizontal elbows allowed 3 Note if more than 1 90 elbow is used hori zon...

Страница 18: ...ct a switch if needed Separate wires to disable CPI activation from remote The SIT Control Module is powered by 120V with an internal transformer for the valve This is pre wired to the factory install...

Страница 19: ...ndividual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psig 3 5 kPa Failure to do so will damage the appliance s gas val...

Страница 20: ...rify that the readings obtained are within specs as shown on the appliance rating plate 6 Be sure to tighten the set screw inside the tap after you have finished taking pressure readings 7 Check for l...

Страница 21: ...Caution Handle contemporary Panels with care 1 Place side panels 2 and 3 in the firebox with notches facing forward as shown above 2 Place rear panel 1 into the back of the firebox 3 Insert the top a...

Страница 22: ...top and two on the bottom Surround clip receivers will push on to these buttons Release the latch located on the bottom of door Pull forward and down Remove the door by pulling the bottom out to 30 d...

Страница 23: ...houette Log Set Installation Optional Your Brigantia Fireplace is approved for use with the Optional Silhouette Log Set The logs come in White Black and Grey Each set comes with 2 logs and you can ins...

Страница 24: ...24 DVRS25NB N 2 24...

Страница 25: ...his unit with the customer the installer must ensure that the appliance is firing correctly and that the electrical system is in working order This will include 1 Perform leak tests of supply line gas...

Страница 26: ...24 DVRS25NB N 2 26 LIGHTING INSTRUCTIONS ON RATING PLATE...

Страница 27: ...replace you build a fire You start with a little bit of tinder and kindling to create small fire and then work your way up to larger logs once a draft has been established Dynamic Start uses the same...

Страница 28: ...ront cover of this manual 3 Do not use this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control s...

Страница 29: ...ce of Continuous Pilot on Demand or intermittent pilot CPI IPI 4 Thermostat and SMART thermostat function 5 Comfort fan speed modulation 6 levels 6 Variable lights 6 levels The Proflame Remote uses a...

Страница 30: ...INSTALLATION OR MAINTENANCE OF THE RECEIVER DEVICE TURN OFF MAIN GAS SUPPLY TO THE APPLIANCE PRIOR TO REMOVING OR REINSERTING THE BATTERIES IN CASE OF REMOTE CONTROL MALFUNCTION TURN OFF THE FIREPLACE...

Страница 31: ...24 DVRS25NB N 2 31 REMOTE CONTROL SETUP AND OPERATION cont...

Страница 32: ...place is started in Smart Thermostat mode the fan will come on 5min after ignition and shut down 12min after fire is turned off This function is disabled when in SMART Thermostat Mode and does not ope...

Страница 33: ...24 DVRS25NB N 2 33 REMOTE CONTROL SETUP AND OPERATION cont...

Страница 34: ...n burner is not turned on for seven continuous days the pilot will turn itself off When the main burner is lit again the cycle repeats The pilot will remain lit for seven days even after the main burn...

Страница 35: ...LCD remote control display Replace batteries Battery Back up Red LED indicator will enter a 1 blink sequence IFC Module will emit a double beep when it receives an ON OFF command from the hand held r...

Страница 36: ...n this manual Inspect the operation of the flame safety system pilot and gas valve Inspect and ensure the lighting of the main burner occurs within 4 seconds of the main gas valve opening Completely i...

Страница 37: ...adjustments and orifice sizing IMPORTANT For high altitude installations above 4500 ft 1372 meters consult local gas distributor or the authority having jurisdiction for proper de rating methods WARNI...

Страница 38: ...24 DVRS25NB N 2 38 CONVERSION KIT INSTRUCTIONS CONT VALVE CONVERSION...

Страница 39: ...ures Test fire the fireplace to confirm correct operation Reinstall door assembly and surround Run through a complete firing cycle to confirm correct operation KIT NUMBERS 24 CKELP for LP gas and 24 C...

Страница 40: ...305 2080 Fuse 3 15A 250V pack of 5 EA 301 0068 43 Orifice Main Burner Orifice Drill to 43 DMS for Natural Gas EA 301 0068 54 Orifice Main Burner Orifice Drill to 54 for LP Gas EA 308 0123 Pilot Assem...

Страница 41: ...e is on and will continued as your fireplace completes its heating function You will likely hear these same sounds more on start up and shut down This is normal for steel fireplaces Q When my applianc...

Страница 42: ...id if work is carried out by an unqualified person s Only original Brigantia parts may be used Please consult your Brigantia dealer or representative if in doubt about a replacement part s OBTAINING W...

Страница 43: ...Address City State Prov ZIP Phone _____ Why did you choose this product Thank you for purchasing our product and filling out this warranty card mm dd yyyy POSTAGE FOLD DOWN AT LINE FOLD DOWN AT LINE T...

Страница 44: ...ARCHGARD FIREPLACES 7116 Beatty Drive Mission B C V2V 6B4 Canada Website www archgard com...

Отзывы: