6
Wire control operation
Wire controller operation
Functions of Buttons
“
”
button
If the machine is on, press this button to turn it off.
If the machine is off, press this button to turn it on. And the TSET will be shown for 5S. Then it will
show the inlet water temperature and working mode. (System will keep the working mode. If no,
the default working mode is Smart mode under Heating.)
During parameter checking or setting, press this button will return to default interface. (The
parameter checking setting will be saved.) Press this button again will turn the machine off.
“
MODE
”
button
Press
“
M” button 3 seconds to convert modes.
Press this button to check and set parameters, With the function of
“▲”“
▼
”
buttons, you can
check current run parameters 1~F.
NO
Meaning
Range
Remarks
1
Inlet water temperature
-50 ~ 99°C
Measured value
2
Outlet water temperature
-50 ~ 99°C
Measured value
3
Outdoor ambient temperature
-50 ~ 99°C
Measured value
4
Exhaust gas sensor temperature
0 ~ 150°C
Measured value
5
Return gas sensor temperature
-50 ~ 150°C
Measured value
6
Heating coil sensor temperature
-50 ~ 150°C
Measured value
7
Cooling coil sensor temperature
-50 ~ 150°C
Measured value
8
Main EEV steps
80 ~ 480
Measured value
9
Auxiliary EEV steps
150 ~ 480
Measured value
A
Current of compressor
0 ~ 30A
Measured value
b
Module temperature
50 ~ 150°C
Measured value
C
DC bus voltage value
Measured value
d
Running frequency of compressor
20 ~ 90Hz
Measured value
E
Rotation speed of fan 1
0 ~ 1599(rpm)
Measured value
F
Rotation speed of fan 2
0 ~ 1599(rpm)
Measured value