Directions for installation and maintenance 

Содержание BP-110HS-SI EIP

Страница 1: ...0 STEP INVERTER Directions for installation and maintenance...

Страница 2: ...Wire control operation General diagram of the refrigerating circuit Safety and control systems Electric diagram 5 Installation p13 Rules of installation Hydraulic connections Electric connections Pro...

Страница 3: ...swimming pools Any other use not in conformity and random will be considered as dangerous and unsuitable The assembly the electric connection and the start up must be carried out by specialized and p...

Страница 4: ...3 2 8 COP A15 W26 W W 4 6 7 1 4 6 7 1 4 50 7 0 Cooling Capacity A35 W28 kW 4 3 1 0 5 3 1 5 6 2 2 3 Power Input kW 1 6 0 24 2 0 0 29 2 45 0 36 Current A 7 5 1 1 9 3 1 5 10 7 2 2 Power Supply V P Hz 22...

Страница 5: ...nometer 6 Fast connection for water outlet 7 Fast connection for water intlet 8 Wire connection for power supply 9 Evaporator 10 Fan 11 Compressor 12 High and low pressure interruptor 13 Titanium heat...

Страница 6: ...5...

Страница 7: ...eters With the function of buttons you can check current run parameters 1 F NO Meaning Range Remarks 1 Inlet water temperature 50 99 C Measured value 2 Outlet water temperature 50 99 C Measured value...

Страница 8: ...tting timer for on and off is the same the setting timer is not available When the setting timer displayed blinks Press MODE to deactivate TIMER SMART Mode Press Smart button to enter smart mode the m...

Страница 9: ...8 Light on under smart mode machine working with the standard frequency Light on under power mode machine working with the high powers Light on under silent mode machine working with the low frequency...

Страница 10: ...aporizing it is then put up in pressure and in temperature by the compressor which sends it in the condenser exchanger where it loses its heat in giving it to the water of swimming pool and comes back...

Страница 11: ...aporator in getting the heat of the water goes through in the compressor which reheats it and through in the gilled radiator which becomes condenser where it comes back to liquid state Evaporator gill...

Страница 12: ...ot damaged in case of overpressurisation of the gas The low pressure protection emits a signal when refrigerant is escaping from the conduits and the unit cannot be kept running 3 Overheating protecti...

Страница 13: ...protection off 2 When the heat pump shut down and ambient temperature 5 outlet water temperature 2 Second anti frost protection activated Heat pump will turn on automatically and run in heating mod e...

Страница 14: ...lace the fan would recycle its air and the Heat pump would be down performance The fan should not blow towards the windows or crossing point Safety distance between the swimming pool and the foot bath...

Страница 15: ...nd connect the pipe if need Hydraulic connections To respect imperatively Connection is carried out with a by pass located on the circuit of filtration upstream appliances of the chemical treatment of...

Страница 16: ...at pump exclusively the circuit breaker must be specified with curve D the fuse must be specified Am Differential protection 30 mA the length of cable between the connector block of the heat pump and...

Страница 17: ...d the current temperature Start between 1 4 minutes in the previous operation mode heating auto cooling Chose the operation mode Press the button 3S MODE Stop for 3 4 minutes reverse of cycle and rest...

Страница 18: ...Pump in these conditions the totality of the water flow goes by the Heat Pump Put into service the Heat Pump in heating mode wait for the indicated pressure being stabilized the correct setting of th...

Страница 19: ...e conditions ar e met it will enter defrosting 3 Defrost operation frequency When entering defrost the frequency is fixed at 60Hz 4 Condition for exit the defrosting After 2 minutes of defrosting when...

Страница 20: ...lains the error codes caused by a defective regulating component or by a security operation Error codes Problem Cause Solution E 03 Water over heating fault Water flow not enough Water flow switch fau...

Страница 21: ...8 Fan motor fault The PCB dial code is wrong Change to the correct dial code E 29 Return gas temperature sensor fault Connection fault Check the connection Return gas temperature sensor fault Replace...