background image

        2.5 Installing the antennas.

 

 

 

 

 

Very Important : Metal should not be situated near the antenna pad 

 

 

 

 

(either underneath or above the pad). 

 

 
 

Metallic items, such as hinges or bars can give interference to the system, causing the system to  

         malfunction. Interference can also be caused by electrical devices and electro-magnetic fields.  
 

As the signal will pass through most non-metallic materials, it is recommended to install the pad  

 

either above or beneath the loft entrance board (eg: plywood with a thickness of no more 15mm).  

 

It is important that air-flow is allowed to the pads to enable the cooling process to take place.  

 

The entrance hole to the loft must be at least 2 cm narrower than the width of the antenna pad.  

 

Bricon produce a range of antenna pads to meet the needs of any loft. There are four pad sizes  

 

available, the 1 field (163 mm wide), 2 field (282 mm), 4 field (482 mm) and 6 field (700 mm).  

 

Bricon antenna will record over the entire width of the pad and therefore tunnels are not needed. It is 

 

advisable however to slow down the bird before it steps onto the antenna. The base of the pad is the side 

 

bearing the label and pad number, and this should be installed face down.  

 

It is advised to install the pads at least 1 metre away from each other to avoid interference.  

 

NB: New generation pads (4 & 6 field - 2009 model onwards) can be placed next to one another

.  

 

 

 

 

Antenna positioned under the landing board and before the bob wires

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

 

 

 

 

 

 
 
 

 

 
 

 

    

X-treme 

Front view 

Landing board 

Antenna pad 

Clocking area 

Max. 11cm. 

Top view 

Landing board 

5 cm. gap 

Clocking area 

The integral 
cable from 
antenna 

Bob wires 

Bob wires 

Antenne 

Internal 

Loft wall 
    Extenal 

!!!Attention: In this set-up, install the antenna pad with the integral cable leading to the  
   outside of the loft. 

Содержание X-treme

Страница 1: ...User Guide UK BRICON nv Europark Oost 15C 9100 Sint Niklaas Tel 32 3 777 39 74 Fax 32 3 778 07 35 Website www bricon be email bricon bricon be versie UK 1 50 or higher X treme...

Страница 2: ......

Страница 3: ...tennas 7 2 4 Antenna testing 8 2 5 Installing the antennas 9 2 6 Connecting and testing the system 12 3 X treme a quick start 3 1 Linking birds 13 3 2 Browse pigeons 13 3 3 Clocking in training 14 3 4...

Страница 4: ...treme to the antennas Connect now the power supply to the connector of the loft antenna With a good working system all red lights on all the antenna plugs are on and the display of the X treme light...

Страница 5: ...X treme 5 M F M F 1 X treme 2 Power supply 3 Antenna 4 Antenna connection 5 End plug M Male pins F Female 1 2 3 3 4 5...

Страница 6: ...he menu After connecting the clock to the antennas you can plug the power supply into the antenna connector and the red power light will illuminate 2 After the start up initialisation you will see the...

Страница 7: ...start the X treme Set date time Browse pigeons Racepoints Delete Basketing Races Antenna test Clocking The X treme is menu driven The complete functionality of X treme is accessed through a menu stru...

Страница 8: ...ntennas It is recommended that you test the antennas at regularly perform Fig 2 The X treme indicates how many antennas are connected With a chip you can test the pro per functioning of the antennas E...

Страница 9: ...f any loft There are four pad sizes available the 1 field 163 mm wide 2 field 282 mm 4 field 482 mm and 6 field 700 mm Bricon antenna will record over the entire width of the pad and therefore tunnels...

Страница 10: ...que way in which the electro magnetic fields within a Bricon antenna overlap each other Having to place a tunnel over the pad and entrance will in most circumstances prove to be a major disadvantage w...

Страница 11: ...of the birds is optimised Another method giving similar results is to build a raised area This raised area is also needed if you have a landing board made from zinc as metal causes interference to th...

Страница 12: ...The mail side pins directed to the clock Mount additional antennas after they are programmed If you connect more than one antenna it is recommended to place the power centrally between the antennas A...

Страница 13: ...re pigeons in the X treme you can scroll through the pigeon list With and Use the and to select the first or last pigeon in the list 3 2 Browsing pigeons X treme 13 Whit this feature you start the clo...

Страница 14: ...nfirm the selection with OK If you wand to clock the same birds again you must first erase the data 10 17 59 BRXA0001 UK V01 60 Delete Delete confirm by pressing OK all clockings are deleted Attention...

Страница 15: ...ts automatically in clocking mode You can not leave the clocking mode by pressing the C button Check carefully if the clock finds all connected antennas Features while clocking Key 1 After pressing ke...

Страница 16: ...OK Or Connect the X treme to your antennas press C If you see the overview screen select with deleting and confirm with OK 4 Other functions PC connection The X treme is connected to the PC via a sta...

Страница 17: ...ked in training Clocking list Press clocking list to preview al clocked birds Linking list Shows the list of al pigeon in the clock 4 3 3 To read out update your X treme Start up PrintManager Press re...

Страница 18: ...will read out the clock After the read out is finished a message you can disconnect the clock by unplugging the USB cable After the read out is done the above message may appear requesting to upgrade...

Страница 19: ...and wait till the screen says no antennas found The flights including training are read The clocked pigeons are displayed on the screen Attention While you are in the monitor screen do not disconnect...

Страница 20: ...ir should be performed by BRICON After start up you see a date for service If your clock approaches this date you must bring in the clock for a complete check by Bricon or a Bricon distributor We repl...

Страница 21: ...paraat voor transponders 125kHz In overeenstemming is met 3 van de R TTE Richtlijn Gezondheid en veiligheid 3 1 a Gebruikte standaards EN60950 1992 A1 A2 1993 A3 1997 A11 1997 EMC 3 1 b Gebruikte stan...

Отзывы: