Intended Usage

The Brewista® Cold Pro Nitro 2 Dual™ Dispenser is a ready-to-use dispenser to tap still and 

nitrogenated and cooled beverages in particular cold-brew coffee from any pressurized 

or non-pressurized container. Such systems are mainly used for professional customers 

in cafes, hotels, restaurants, and bars.  The nitrogen effect is created through filtered 

compressed air which contains 78% nitrogen and chilling it to 36°F (2°C).  The device is 

only approved for this application and is not suitable for cooling hot liquids, unfiltered 

liquids, chemicals, or similar substances. The Brewista® Cold Pro Nitro 2 Dual™ Dispenser 

must only be operated by a trained person. The appliance is not to be used by persons 

(including children) with reduced physical, mental, or sensory abilities or with scarce 

experience and/or expertise, unless they are supervised by a person responsible for their 

safety, or they are instructed by this person on how to properly use the Cold Pro Nitro 2 

Dual™ machine.

Operation Instructions

Assemble your Cold Pro Nitro 2 Dual™

1)  Place the device in a level, clean, and dry location. Ensure there is enough 

space around the machine for proper ventilation — about one inch (2.54 cm) 

from the side vents and 4 inches (10 cm) from the top.

2)  Let the machine sit upright for 5 hours before first use so the compressor 

works properly.

3)  Assemble the tap handles (1) by screwing each on at the top of the dispenser’s 

spout component [(2) and (3)].

4)  Ensure the power button (7) at the bottom of the machine is switched off. If 

the red light inside of the switch is off, then the air compressor is off. 

5)  Plug in the power cord (9) to a grounded outlet (refer to Additional 

Safeguards, page 3).

6)  Connect the intake lines (13) to the Cold Pro Nitro 2 Dual™ by pushing the 

male elbow coupler (14) into the female couplers [(5) and (6)] at the bottom of 

the machine located at the far end of the machine on the bottom. 

 

Lift the machine slightly if needed.

 

The female coupler 

nearest to the side

 (5) of the machine feeds to the 

spout that will dispense chilled 

still

 cold brew.

 

The female coupler 

nearest to the center

 (6) of the machine feeds to the 

spout that will dispense chilled 

nitro

 cold brew.

 

To release the coupler attachment, push the metal spring component to 

loosen. 

7)  The pre-filter comes attached upon delivery of the Cold Pro Nitro 2 Dual™ 

machine. Ensure all tubing is installed firmly at all connections to prevent air 

bubbles from entering the tube.  Tubing may have loosened during shipment.

 

Note: 

If a filter adapter is not part of both intake lines, coffee grounds 

or other particles could block the jet nozzles in the device or impair the 

functionality of the membrane pump and make the device unusable. 

Connect your Cold Brew Container 

• 

Note: 

Brewista recommends checking functionality of your system by using 

water.  This will also help flush out any cleaning solution residue from the 

system as well. 

Содержание Cold Pro Nitro 2 Dual

Страница 1: ...Customer Service North America 1 888 538 8683 Local Wyoming USA 307 222 6086 Email help mybrewista com READ THIS MANUAL PRIOR TO FIRST USE AND SAVE FOR FUTURE REFERENCE 1 year Limited Warranty V2PX NS...

Страница 2: ...Avoid contacting moving parts Do not insert objects into rotating parts fan or compressor Prevent dirt dust fibers etc from entering the unit Operate the Cold Pro Nitro 2 Dual in a dust free environm...

Страница 3: ...ppliance must be grounded while in use CAUTION To ensure continued protection against risk of electric shock connect to properly grounded outlets only GROUNDING INSTRUCTIONS In North American markets...

Страница 4: ...evel 8 Higher Cooling Power for High Volume Dispensing 8 Filtration 8 Decomissioning 8 Product Shelf Life 9 Downtimes 9 Cleaning Instructions 9 Maintenance 10 Remove Dust at Condensator Grid 10 Changi...

Страница 5: ...Cold Brew Inlet 7 Power Button 8 Non slip Feet 9 Power Cord 10 Air Intake Vent 11 Control Panel Cover protects Temperature Control and Gas Level Control 12 Bag in Box Adaptors 13 Intake Line 2 0 m wi...

Страница 6: ...3 Assemble the tap handles 1 by screwing each on at the top of the dispenser s spout component 2 and 3 4 Ensure the power button 7 at the bottom of the machine is switched off If the red light inside...

Страница 7: ...ors if you choose Simply attach your desired BiB adapter to the intake tube and use a corresponding BiB bag with the appropriate nozzle If you do not wish to use a BiB system simply remove the BiB ada...

Страница 8: ...ed in the intake line to prevent damage to the interior components of your Cold Pro Nitro 2 Dual Thick liquids risk slowing down the liquid pump inside the machine Decommissioning Before putting the d...

Страница 9: ...ntling parts 2 Unscrew spout 3 and rinse it with fresh water Use a brush if needed to remove any particles in the strainer Reassemble tap parts 1 2 and 3 3 Disconnect the intake filter 15 and unscrew...

Страница 10: ...arts depends on the specific system being used Brewista recommends checking these connections about once a month to ensure proper system function Other Maintenance and Repairs In case of failure probl...

Страница 11: ...system causes air leaks that need to be removed Dispensed coffee is not cold enough No electrical power or temperature control is turned off Check the dispenser s electrical connection If the air com...

Страница 12: ...e Filter adapter 15 in the intake line is clogged Check to see if the filter strainers are clogged and clean per instructions on page 9 of this manual if needed Air compressor is turned off or has no...

Страница 13: ...ns of this manual page 9 Check to see if there is a blockage 2 Test to see if the dispenser pours 3 If not there may be a bigger blockage in the liquid pump You will need to unscrew the spout 4 Remove...

Страница 14: ...quality or repair attempts by non authorized persons are not covered by the warranty The same applies for failure to comply with the use of consumables e g cleaning and decalcifying agents that do no...

Страница 15: ...e unit in water or any other liquid This may cause electric shock or damage the appliance TECHNICAL DATA For countries with voltage ranging from 110 127V Rated voltage 115 V 60 Hz Rated current 3 2A R...

Страница 16: ...1133 W 27th Street Cheyenne WY 82001 USA www mybrewista com Toll Free in North America 888 538 8683 Local 307 222 6086 V2PX NS...

Отзывы: