3. Set up power supply for the remote sensor.

4. Position the base station and the remote sensor within the effective transmission range.

When changing batteries always change all batteries and replace them in the correct order, so the re-
mote connection can be re-established. If either of the devices is mains-powered, the power supply
must be disconnected for a short moment also for this device when exchanging the batteries. If batter-
ies are exchanged in only one of the devices (i.e. the remote sensor) the signal can’t be received or
can’t be received correctly.

Note, that the effective range is vastly affected by building materials and position of the main and re-
mote units. Due to external influences (various RC devices and other sources of interference), the
maximum distance can be greatly reduced. In such cases we suggest to position the main unit and the
remote sensor at other places. Sometimes all it takes is a relocation of one of these components of a
few inches! Though the remote unit is weather proof, it should be placed away from direct sunlight,
rain or snow.

9 Setting up power supply

Base unit

1. Remove the battery compartment cover.

2. Insert the batteries into the battery compartment. Ensure that the battery polarity (+/-) is correct.

3. Replace the battery compartment cover.

Remote sensor

4. Loosen the screw at the battery compartment cover with a small Philips screwdriver and remove

the cover.

5. Insert the batteries into the battery compartment. Ensure that the battery polarity (+/-) is correct.

6. Replace the cover and retighten it with the screw.

10 Assembling and installing the multifunctional

remote sensor

Depending on the desired location, the remote sensor can be installed in two different ways.

NOTICE! During the assembly make sure that the upper part of the wind vanve is minimum 1.5
meters off the ground. Use the circular level in the sensor head to ensure a level installation. The
windmill must point to the North.

Assembly on a vertical or horizontal wooden element

1. Slide one end of the assembly bar into the aperture below the sensor head.

2. Slide one screw through the bore hole and put on the nut on the opposite site. Tighten the screw

connection by hand.

3. Depending on the desired orientation, slide the opposite end of the assembly bar into the aperture

for vertical or horizontal mounting of the assembly base.

4. Slide another screw through the bore hole of the assembly base and put on the nut on the oppos-

ite site. Tighten the screw connection by hand.

5. Place the assembly base with its bottom site first on a wooden element. Use 4 wood screws to

tighten it.

Assembly on a vertical or horizontal tube

6. Repeat steps 1 to 4 as before.

7. Place the assembly base with its bottom site first on the tube. Push the tube bracket against the

tube from the opposite site.

Содержание XXL Weather Center JC

Страница 1: ...Wetterstation Weather Station XXL Weather Center JC DE Schnellstartanleitung EN Quickstart guide...

Страница 2: ...ant le code QR ou le lien correspondant NL Bezoek onze internetpagina via de volgende QR code of weblink voor meer informatie over dit product of de beschikbare vertalingen van deze gebruiksaanwijzing...

Страница 3: ...Deutsch 4 English 12...

Страница 4: ...i Website etc ohne eine vorherige schriftliche Genehmigung des Herstellers ist nicht gestattet Die in dieser Dokumentation verwendeten Bezeichnungen und Markennamen der jeweiligen Firmen sind im Allge...

Страница 5: ...anuelle Zeiteinstellung 9 BARO Taste Wechsel zwischen Anzeige in hPa InHg oder mmHg sowie Wahl der Luft druckart 10 WIND Taste Wechsel zwischen durchschnitt licher und aktueller Windb e 11 RAIN Taste...

Страница 6: ...Hygrometer 7 Rohrschelle 8 Montageschuh 9 Montagestange 10 Batteriefach abdeckung 11 RESET Knopf 12 LED Funktionsleuchte 13 Montageschrauben mit muttern 6 Lieferumfang Basisstation A multifunktionale...

Страница 7: ...k 10 Windgeschwindigkeit 11 Windrichtung 12 Wind Indikator 13 Informationen zu gef hlter Temperatur Windk hle Taupunkt und Hitzeindex 14 Beaufort Skala zur Windst rkeneinord nung 15 Luftfeuchtigkeit a...

Страница 8: ...en Basisger t 1 Batteriefachdeckel entfernen 2 Batterien in das Batteriefach einsetzen Dabei die korrekte Ausrichtung der Batteriepole be achten 3 Batteriefachdeckel wieder aufsetzen Funksensor 4 Schr...

Страница 9: ...wa 3 8 Minuten bis dieser Prozess abgeschlossen ist Bei korrektem Empfang des Funksignals werden Datum und Uhrzeit automatisch eingestellt und das Empfangssymbol wird angezeigt Wird kein Funksignal em...

Страница 10: ...fsatz vorsichtig nach unten ab 7 Entfernen Sie vorsichtig Schmutz und Insekten aus dem Sensorgeh use Hinweis Der Lamellenaufsatz besteht aus einzelnen ineinander gesteckten Elementen Die beiden unters...

Страница 11: ...hgekreuzten M lltonne sowie dem chemischen Sym bol des Schadstoffes bezeichnet Cd steht f r Cadmium Hg steht f r Quecksilber und Pb steht f r Blei 17 Garantie Die regul re Garantiezeit betr gt 2 Jahre...

Страница 12: ...s image file website etc is not permitted without the prior written consent of the manufacturer The terms and brand names of the respective companies used in this document are protected by brand paten...

Страница 13: ...ton manual time setting 9 BARO button display change between hPa InHg or mmHG as well as barometric pressure type selection 10 WIND button display change between aver age and current gust 11 RAIN butt...

Страница 14: ...rometer 7 Pipe clamp 8 Mounting shoe 9 Mounting bar 10 Battery compartment cover 11 RESET button 12 LED function indicator 13 Mounting screws with nuts 6 Scope of delivery Base station A power adapter...

Страница 15: ...mation on feels like temperature wind chill dew point and heat index 14 Beaufort scale for wind force classification 15 Outdoor humidity 16 Sensor signal strength indicator 17 Outdoor temperature 18 W...

Страница 16: ...e sensor 4 Loosen the screw at the battery compartment cover with a small Philips screwdriver and remove the cover 5 Insert the batteries into the battery compartment Ensure that the battery polarity...

Страница 17: ...eive the time signal go ahead with the following steps 1 Press RCC button on the base station until radio signal symbol flashes 2 If the device is still not receiving the signal the time must be set m...

Страница 18: ...per Directive 2012 19 EC of the European Parliament on waste electrical and electronic equipment and its adaptation into German law used electronic devices must be collected separately and recycled i...

Страница 19: ......

Страница 20: ...e mail e mail sav bresser fr T l phone 33 494 592 599 BRESSER France SARL P le d Activit s de Nicopolis 260 rue des Romarins 83170 Brignoles France Prix d un appel local depuis la France ou Belgique S...

Отзывы: