background image

 

 

 

 

Hold  “OUT-TEMP  ALERT”  button  (B8)  for 3 seconds to enter  outdoor 

temperature alert setting. Icon “ ” or “ ” beside temperature’s digits flash. 

Press  “

” or “

“button  (B1 or B3 button)  to adjust the setting value, press 

“OUT-TEMP ALERT”  button to confirm the setting. Setting Sequence as follow: 

Upper limit of temperature, Lower limit of Temperature.   

 

When it’s alert, the corresponding icon “ ”  or  “ ”  and  temperature digit 
would flash on the LCD. Press any buttons to stop the alert sound

otherwise, it 

will sound for 2 minutes, and stop automatically. 

 

 
(6)    Comfort Indicator Bar: for the display of pleasant/unpleasant climate.   

 

7. Time and Alarm Setting 

7.1 Radio Controlled Clock: 

 

After batteries inserted and main unit finishes receiving the transmission from 

outdoor sensor, the clock automatically starts to scan the DCF time signal. Radio 

Control Icon“

” flashes on the LCD. 

  flashes

 

Indicating now is receiving 

DCF signal 

turns on, 

Indicating signal received 

successfully 

  disappear, 

Indicating signal reception 

failed 

 

The clock automatically scans the time signal at 3.00 a.m. every day to maintain 

accurate timing. If reception fail, scanning stops (“

” on LCD disappear)   

 

The clock can be set to scan the time signal manually by holding  “

”  and 

“button  for 3 seconds.  Each reception takes about 5 minutes.    If receptions 

fail, scanning stops. 

 

  Stop scanning by holding “

” and “

“button for 3 seconds. 

 

  “

DST

” shown on the LCD if it is in daylight saving time mode. 

 

7.2 Manual Time Setting: 

 

Hold “MODE” button (B2) for 3 seconds to enter Clock/Calendar setting mode. 

 

Press “

” or “

” button to adjust the setting and press “MODE” button to confirm 

each setting. 

(By keeping the

 “

” or “

” 

button pressed, could accelerate the process and reach 

Содержание ClimaTemp WS

Страница 1: ...INSTRUCTION MANUAL Weather Station ClimaTemp WS Thermo Hygrosensor...

Страница 2: ...ponded time 24 Hours Min Max Display for Outdoor Humidity 1 4 Temperature Indoor measurable range 10 50 C Measures C F user selectable Outdoor measurable range 20 50 C Outdoor Temperature Record from...

Страница 3: ...24 hours highest lowest temperature record A9 Past 24 hours highest lowest humidity record A10 Indoor temperature A11 Indoor humidity A12 Comfort indicator 2 2 Part B Buttons B1 C F button B2 MODE SE...

Страница 4: ...oduct will switch to the external power supply automatically 4 2 Outdoor Thermo Sensor Batteries compartment D4 of thermo sensor is locating behind the back cover Insert 2 x AAA batteries observing po...

Страница 5: ...etween local weather station and this unit the local weather station s forecast should prevail The manufacture will not hold responsible for any trouble that may come up due to wrong forecasting from...

Страница 6: ...cord Time date for lowest humidity memory record Time and date for highest humidity memory record 3 Celsius Fahrenheit Press C F button B1 to select Indoor Outdoor Temperature in Celsius mode or Fahre...

Страница 7: ...tdoor sensor the clock automatically starts to scan the DCF time signal Radio Control Icon flashes on the LCD flashes Indicating now is receiving DCF signal turns on Indicating signal received success...

Страница 8: ...ed to zero only 2 The time setting mode will automatically exit in 15 seconds without any adjustment 3 The time zone is used for the countries where can receive the DCF time signal but the time zone i...

Страница 9: ...emoved Do not expose it to direct sunlight heavy heat cold high humidity or wet areas The outdoor sensor must not be set up and installed under water Set it up in away direct sunlight and Rain Never c...

Страница 10: ...10...

Страница 11: ...11...

Страница 12: ...12 BRESSER GmbH Gutenbergstr 2 46414 Rhede Germany Errors and changes excepted All rights reserved Copyright 2019 by BRESSER GmbH Rhede Germany Manual_7007320_ClimaTemp WS_de_BRESSER_v092019a doc...

Отзывы: