background image

Thermo-Hygrosensor 8 Channel

433MHz 

Art. No. 7009998

Station

Sensor

Wait 5s

5 sec.

NOTE!

Do not disassemble the device. In the event of a defect, please 

contact your dealer. The dealer will contact the Service Centre 

and can send the device in to be repaired, if necessary.

Use only the recommended batteries. Always replace weak or 

empty batteries with a new, complete set of batteries at full ca-

pacity. Do not use batteries from diff erent brands or with diff er-

ent capacities. The batteries should be removed from the unit if 

it has not been used for a long time.

NOTES ON CLEANING

Separate the device from the power supply or remove the bat-

teries before cleaning.

NOTE!

Only use a dry cloth to clean the exterior of the device. Do not 

use any cleaning fl uid to avoid damaging the electronics.

SCOPE OF DELIVERY

Outdoor sensor, instruction manual, batteries required (not 

included): 2 pcs. Batteries (1.5V, type AA)

FEATURES OF THE REMOTE UNIT

A

B

C

F

E

D

A  LED INDICATOR

Flashes when information is being transmitted to the weather 

station.

B  WALL MOUNT

For mounting the sensor on walls.

C  SET the transmission channel (1-8)

Input channel for the weather station. Set the channel before 

inserting the batteries.

D  RCC BUTTON

Initialize time signal reception.

E  RESET BUTTON

Press to reset all setting if you have selected diff erent channel.

F  BATTERY COMPARTMENT

Unit requires 2 pcs. UM-3 or “AA” 1.5V batteries.

FIRST OPERATION

1.  Open the battery compartment cover.

2.  Set the desired channel with the switch. If you are using only 

one transmitter, please leave the selection at „1“.

3.  Insert 2 new UM-3 or „AA“ 1.5V batteries observing correct 

polarity.

4.  Close the battery compartment cover and set the unit in the 

desired location.

Although the outdoor sensor is weatherproof, it should not be 

placed in places exposed to direct sunlight, rain or snow.

TIPS FOR SETTING UP:

Please follow the instructions below to ensure optimum opera-

tion of the equipment:

1. Assign each external transmitter unit its own channel.

2. Place the receiver unit and transmitter unit within 1 meter 

of each other and activate the manual search for available 

signals from all connected outdoor sensors on the main unit 

(weather station not included with delivery). 

DISPOSAL

Dispose of the packaging materials properly, accord-

ing to their type, such as paper or cardboard. Contact 

your local waste-disposal service or environmental 

authority for information on the proper disposal.

Do not dispose of electronic devices in the household 

garbage! As per the Directive 2002/96/EC of the Eu-

ropean Parliament on waste electrical and electronic 

equipment and its adaptation into German law, used 

electronic devices must be collected separately and recycled in 

an environmentally friendly manner.

In accordance with the regulations concerning batteries 

and rechargeable batteries, disposing of them in the nor-

mal household waste is explicitly forbidden. Please make 

sure to dispose of your used batteries as required by law – 

at a local collection point or in the retail market. Disposal in domestic 

waste violates the Battery Directive.

Batteries that contain toxins are marked with a sign and a chem-

ical symbol.

Cd¹

Hg²

Pb³

1 battery contains cadmium

2 battery contains mercury

3 battery contains lead

EC DECLARATION OF CONFORMITY

Hereby,  Bresser  GmbH  declares  that  the  equipment 

type with part number: 7009998 is in compliance with 

Directive: 2014/53/EU. The full text of 

the EU declaration of conformity is available at the 

following internet address: 

www.bresser.de/download/7009998/CE/7009998_CE.pdf

UKCA DECLARATION OF CONFORMITY

Bresser UK Ltd. has issued a „Declaration of Conform-

ity“ in accordance with applicable guidelines and cor-

responding standards. The full text of the UKCA decla-

ration of conformity is available at the following internet 

address: 

www.bresser.de/download/7009998/UKCA/7009998_UKCA.pdf

Bresser UK Ltd. 

· Edenbridge, Kent TN8 6HF · Great Britain

TECHNICAL DATA

Measurement

Temperature range: 

 -40-60 °C/-40-140 °F 

(in steps of 0.1 °C/°F)

Humidity range: 

1-99% RH (in steps of 1%)

Transmission

Transmission frequency:  433,92 MHz 

Maximum transmission power: 

< 10mW

Transmission range: 

30 meters (free fi eld)

Power supply

2x AA 1.5V batteries (not included)

GB

Instruction Manual

GENERAL WARNING

  DANGER!

This device contains electronic components which operate via 

a power source (power supply and/or batteries). Do not let 

children use the device while unattended. Only use the device 

as described in the manual, otherwise you run the risk of an 

electric shock.

Children should only use the device under adult supervision. 

Keep packaging material, like plastic bags and rubber bands, 

out of the reach of children, as they pose a choking hazard.

Keep batteries out of the reach of children. Make sure you insert 

the batteries correctly. Empty or damaged batteries could cause 

burns if they come into contact with the skin. If necessary, wear 

adequate gloves for protection.

 DANGER!

Do not expose the device to high temperatures. Use only the 

recommended batteries. Do not short-circuit the device or 

batteries, or throw them into a fi re. Excessive heat or improper 

handling could trigger a short-circuit, a fi re or an explosion!

Manual_7009998_Thermo-Hygro-8CH-Sensor_de-en_BRESSER_v102021a

Bresser GmbH

Gutenbergstraße 2

46414 Rhede · Germany
www.bresser.de

Bresser UK Ltd.

Suite 3G, Eden House 

Enterprise Way, Edenbridge, 

Kent TN8 6HF, Great Britain

        

  @BresserEurope

www.bresser.de/P7009998

MANUAL DOWNLOAD:

Manual_7009998_Thermo-Hygro-8CH-Sensor_de-en_BRESSER_v102021a.indd   2

Manual_7009998_Thermo-Hygro-8CH-Sensor_de-en_BRESSER_v102021a.indd   2

21.10.2021   15:01:46

21.10.2021   15:01:46

Отзывы: