OPERATION OF THE HYBRID MAINS FLOODLIGHT WITH BATTERY (4050 MH)
Use the switch (A) on the back to switch the floodlight on.
Press the switch multiple times to set the brightness to 100 %, then 50 %, then 25 % and then “off”.
The lower the brightness selected, the longer the floodlight will burn.
If the switch is left in any of its “on” positions for longer than 5 seconds, then pressing it once again will always turn it off.
If the plug-in power supply is connected and plugged in while the floodlight is switched on, the floodlight will flash
3 times and then automatically switch into mains operation with 100 % light.
OPERATING THE HYBRID FLOODLIGHT WITH MAINS POWER
The hybrid floodlight connects to the mains power from the PSU plug (E) via the charging cable (D) to the
charging port (B).
A
E D C B
(A) Switch
(B) Charging port
(C) Battery, status and charge indicator
(D) Charging cable
(E) Power supply unit
By pushing the On switch, the floodlight produces light.
In the event of a power failure or if the mains plug is unplugged, the floodlight will flash 3 times and then automatically
switch into battery operation with 100 % light.
If the hybrid floodlight is connected to the mains, the battery is charged. The charging display flashes.
It can shine light while being charged.
The battery charges fastest when the floodlight is switched to “off”.
BATTERY STATUS INDICATOR
Indicates the current battery charge, showing how much energy is still available.
The battery status indicator (C) appears automatically when the floodlight is switched on.
While the battery is charging, the status indicator (C) shows the battery’s charge level.
If all 4 LEDs are lit, the battery is fully charged.
If the battery is almost empty, the floodlight flashes 5 times and the battery status indicator (C) flashes continuously.
Afterwards, the floodlight will remain on for approx. 10 minutes before the light is switched off by the deep discharge
protection function. This ensures sufficient time to complete work.
CHARGING THE BATTERY
1. The product can be used during charging.
2. To ensure optimum function, we recommend fully discharging the battery on the first use and fully charging it
afterwards.
3. The charging port (B) is located under the cover cap on the side of the floodlight.
4. The charging status of the battery is indicated by the battery status indicator (see description above).