Wireless door / window contact 868.3 MHz
Wireless door / window contact 868.3 MHz
Note:
The door and window contact's sensitivity can be limited by
the distance between the electronics unit and magnet unit. The
electronics unit's reactivity can be checked using the integrated LED.
If even leaning on the door or window means it is recognised as
being open, the magnet unit must be moved in the direction of the
opening and affixed to the electronics unit.
Installation
Installation without drilling
Note:
Check before installation whether the product is located within
the range of the Gateway.
Use both adhesive pads to attach the wireless door / window
contact to the window / to the door without drilling.
The arrows on the electronics and installation unit should be
pointing each other.
Ensure that the installation area is clean, dust-free and dry.
Avoid installation locations which are under the strong influence
of heat (e.g. sunlight) as the adhesive tape can come unstuck.
Do not use any spacers as the device to be installed using the
adhesive pads will become too heavy.
Adhesive pad
position
Installation using screws
Note:
By attaching the device using screws, the window frame will
be damaged. If you live in rented accommodation, this may result in
a claim for damages or your deposit being withheld.
Install the electronics unit and the magnet unit parallel to one
another at a maximum distance of 8 mm. Ensure that the arrows
depicted on the back of the device are at the same height.
Note:
As there are only spacers for the magnet unit, as a general
rule, the electronics unit must be installed on the higher or
prominent part.
Remove the installation plate from the electronics unit and the
magnet unit respectively.
Draw the drill holes onto the door/ onto the window using a
pencil, with the help of the installation plates.
Drill the marked holes using a suitable drill.
Screw the installation plates using the screws provided to the
door/ to the window.
Press the electronics unit and the magnet unit onto the
respective installation plate until it audibly clicks into place.
Balancing out the assembly level of the
magnet unit
13 mm
13 mm
If you are
not
using
any
spacer
or
are only using
one
(3 mm
or 5 mm) use 2 x 13 mm screws.