12
WIRING DIAGRAM:
ELECTRONIC DHW HP CONTROLLER
USER INTERFACE:
2-line display (The Control Panel setup, see also control panel drawing on page 7).
The upper line displays the parameter menu (function).
The bottom line displays the parameter status or value.
The display is activated (indicated) by turning or pressing the rotary-/push button (no. 32 on the control panel drawing).
To scroll through the menu turn the rotary-/push button.
You have 12 menus. The far left is the menu
”WATER”
(indicates the actual DHW temperature).
If you want to change the status or value of a parameter, push shortly the rotary-/push button; the status/value line will now
start flushing. While the display is flushing you can vary the status/value by turning the rotary-/push button. When the
desired value is indicated push the rotary-/push button again to acknowledge the chosen status/value. If you don’t
acknowledge the value while the display is flushing, the status/value remains unchanged.
If you press t the rotary-/push button for more than 3 seconds, you get to the service parameter menu. This expert menu is
reserved for the installer. Please do not change these settings without consulting your installer. None authorized settings in
this menu might be the cause of warranty exclusion
.
Water
45
°°°°
C
Reprezentant unic in Romania - airguru.ro BREEZE HVAC SRL