background image

 

 

4  DESCRIPTION 

4.1 

Identification of the product 

The pulsation damper and pulsation damper hose can be identified by the contents of the 
identification plate on the pulsation damper housing and the hose label. 
The identification plate of the pulsation damper contains the following information, relevant for 
identification: 

 

A.  Type 
B.  Serial number 
C.  Identification number of Notified 

Body  

D.  Year of manufacture 

The hose label on the pulsation damper hose contains following information: 

 

A.  Re-order number 
B.  Internal diameter 
C.  Type of material of inner liner 
D.  Maximum permissible working pressure 
E.  Production code 

4.2 

Operation of the pulsation damper 

The Bredel pulsation damper reduces the pulses created in the discharge line by the hose pump. This 
is achieved by means of a thick-walled, reinforced rubber hose which is mounted in a carbon steel, 
cylindrical pressure vessel. The hose is surrounded by compressed gas (air or nitrogen). 

When a pressing shoe leaves the pump hose, while rotating , instantly the volume in the discharge line 
will increase with the volume of the pump hose now released by the pressing shoe. This will result in 
a momentary deceleration of the fluid which results in a pressure drop in the discharge line. 

Содержание PD/100

Страница 1: ...Pulsation damper series PD 40 PD 65 and PD 100 Manual ORIGINAL INSTRUCTIONS...

Страница 2: ...plies to all damage inclusive of without limitation compensating direct indirector consequential damage loss of data income or profit loss or damage to possessions and claims of third parties Watson M...

Страница 3: ...4 Pulsation damper selection 10 5 INSTALLATION AND COMMISSIONING 11 5 1 Unpacking 11 5 2 Inspection 11 5 3 Installation conditions 11 5 3 1 Ambient conditions 11 5 3 2 Set up 11 5 4 Lifting and moving...

Страница 4: ...ents installation maintenance or repair jobs which fall beyond the scope of this manual contact your Bredel representative Make sure you have the following information at hand serial number pulsation...

Страница 5: ...rm resulting from this The pulsation damper is designed in conformance with the current European standards and directives Only use the pulsation damper in conformance with the intended use described a...

Страница 6: ...any responsibility for damage or harm caused by not strictly observing the safety regulations and instructions in this manual or by negligence during installation use maintenance and repair of the pul...

Страница 7: ...his manual The safety form must be applied to the outside of the shipping carton Parts which have been contaminated or which have been corroded by chemicals or other substances which can pose a health...

Страница 8: ...diameter C Type of material of inner liner D Maximum permissible working pressure E Production code 4 2 Operation of the pulsation damper The Bredel pulsation damper reduces the pulses created in the...

Страница 9: ...o be pumped Dependent on the specific requirements of your application a matching hose should be selected A Outer extruded layer made of natural rubber B Four nylon reinforcement layers C Inner extrud...

Страница 10: ...your hose pump Selection table pump and pulsation damper Pulsation damper type Pump type PD 40 Bredel 25 Bredel 32 Bredel 40 PD 65 Bredel 50 Bredel 65 PD 100 Bredel 80 Bredel 100 If you are in doubt a...

Страница 11: ...commended to use Y connections instead of T connections The pulsation damper will be most effective if it is directly mounted onto the hose pump Minimise the distance between pump and pulsation damper...

Страница 12: ...onsfor lifting movements are adhered to and that the lifting is carried out by qualified personnel only 5 5 Setting the pulsation damper pressure level for operation The pulsation damper air or nitrog...

Страница 13: ...v inside the vessel 6 Pressurize the vessel to approximately 80 of the actual fluid discharge pressure of the hose pump p2 close to the pulsation damper 7 Continue to fill the vessel with gas and clos...

Страница 14: ...ump back on ensure that all valves present in the pipe work are opened 6 1 Cleaning the pulsation damper hose internally The inside of the pulsation damper hose is easily cleaned by flushing the pump...

Страница 15: ...d used hose 1 Check all parts to be installed for any damage and replace when necessary 2 Grease all metal parts which are not corrosion protected and O rings with Molykote 55M or equivalent 3 Place o...

Страница 16: ...nstalling an additional flange on both sides of the pulsation damper flangesand external gas pressure up to 1600 kPa 16 bar 232 psi above atmospheric can be applied 6 4 Checking the Pressure relief va...

Страница 17: ...ose Pressure loss at pulsation damper housing Damaged O ring pos 4 or 5 Replace the O ring concerned Pressing ring pos 7 incorrectly mounted Tighten to the specified torque settings see paragraph 8 2...

Страница 18: ...n Unit PD 40 PD 65 PD 100 Pressing ring pos 7 Thread M115 x 2 M145 x 2 M185 x 3 Torque value N A N A N A Toolbar diameter mm 16 16 16 inch 0 63 0 63 0 63 Hose clamp pos 8 Thread M8 M8 M10 Torque value...

Страница 19: ...redel 65 20 6 3 65 8 145 185 PD 100 Bredel 80 100 324 1356 1295 20 8 8 48 175 80 8 160 200 18 Bredel 100 22 3 100 180 220 Dimensions in inch Damper Type Pump Type A B C D E F G K1 K2 n L M N Steel SS...

Страница 20: ...32 P040293 2 Flange steel EN 40 40 P040209 2 Flange steel EN 65 50 P065213 2 Flange steel EN 65 65 P065209 2 Flange steel EN 80 100 P100213 2 Flange steel EN100 100 P100209 2 Flange steel ASA 40 25 P...

Страница 21: ...Insert PVC PD 100 100 P100212 2 Insert PP PD 100 100 P100292 2 Insert PVDF 100 100 P100282 11 8 Bolt M8 x 20 F111071 8 Bolt M10 x 25 F111096 8 Bolt M12 x 30 F111130 12 8 Washer M8 Spring Lock F336011...

Страница 22: ...group I dangerousfluids and were subjected to the conformity assessment procedure as mentioned in the table below Type examination module B has been in conformity with AD 2000 Edition 2002 Type Modul...

Страница 23: ...f the packaging containing the item s The sender of the item s is responsible for cleaning and decontaminating of the item s before returning them in such w ay that it is safe for the receiver to open...

Страница 24: ...978 658 0041 E mail support wmftg us Internet www wmftg com Other areas Watson MarlowBredel B V P O Box 47 NL 7490 AA Delden The Netherlands Phone 31 74 3770000 Fax 31 74 3761175 E Mail bredel wmftg...

Отзывы: