Fig.24
2.
Remove the second sealing ring (10) from the upper body.
Fig.25
®
The shaft bearing is removed.
9.3.4
Removal of individual parts from the upper body.
Carry out the following steps:
1.
Carefully pry open and remove the circlip (30) with a small screwdriver.
Fig.26
2.
Clamp the designated spanner flats of the upper body with a soft-padded
vice.
3.
Using the bevel gear tool (SP3), carefully unscrew the bevel gear (12) in a
counter-clockwise direction.
Maintenance
Disassembly
430BAL011762EN_2
28.05.2018
41