background image

14 

Ussc

TYPE

WEIGHT

(LBS. CU. FT., DRY)

PER CORD

EFFICIENCY 
RANKING

SPLITS

MILLIONS 
BTU’s/CORD

Hickory

63

4500

1.0

Well

31.5

White Oak

48

4100

.9

Fair

28.6

Red Oak

46

3900

.8

Fair

27.4

Beech

45

3800

.7

Hard

26.8

Sugar Maple

44

3700

.6

Fair

26.2

Black Oak

43

3700

.6

Fair

25.6

Ash

42

3600

.5

Well

25.0

Yellow Birch

40

3400

.4

Hard

23.8

Red Maple

38

3200

.3

Fair

22.6

Paper Birch

37

3100

.3

Easy

22.1

Elm/Sycamore

34

2900

.2

Very Diffi

  cult

20.1

Red Spruce

29

1800

.1

Easy

16.1

WOODSTOVE UTILIZATION

Your heating unit was designed to burn wood only;  no other materials should be burned.  Waste and other fl ammable materials 
should not be burned in your stove.  Any type of wood may be used in your stove, but specifi c varieties have better energy yields 
than others.  Please consult the following table in order to make the best possible choice.

It is EXTREMELY IMPORTANT that you use DRY WOOD only in your wood stove.  Th

  e wood should have dried for 9 to 15 months, 

such that the humidity content (in weight) is reduced below 20% of the weight of the log.  It is very important to keep in mind that 
even if the wood has been cut for one, two or even more years, it is not necessarily dry, if it has been stored in poor conditions.  Under 
extreme conditions it may rot instead of drying.  Th

  is point cannot be over stressed; the vast majority of the problems related to the 

operation of a wood stove is caused by the fact that the wood used was too damp or had dried in poor conditions.  Th

 ese problems 

can be:

- ignition problems
- creosote build-up causing chimney fi res
- low energy yield
- blackened windows
- incomplete log combustion

Smaller pieces of wood will dry faster. All logs exceeding 6” in diameter should be split.  Th

  e wood should not be stored directly on 

the ground. Air should circulate through the cord. A 24” to 48” air space should be left  between each row of logs, which should be 
placed in the sunniest location possible. Th

  e upper layer of wood should be protected from the elements but not the sides. 

TESTING YOUR WOOD

When the stove is thoroughly warmed, place one piece of split wood (about fi ve inches in diameter) parallel to the door on the bed 
of red embers.

Keep the air control full open by pulling on it and close the door. If ignition of the piece is accomplished within 90 seconds from the 
time if was placed in the stove, your wood is correctly dried. If ignition takes longer, your wood is damp.

If your wood hisses and water or vapor escapes at the ends of the piece, your wood is soaked or freshly cut. Do not use this wood in 
your stove. Large amounts of creosote could be deposited in your chimney, creating potential conditions for a chimney fi re.

Содержание SWC31

Страница 1: ...is entire manual before you install or useyournewroomheater Failuretofollowinstruc tions may result in property damage bodily injury or even death Improper Installation Could Void Your Warranty CONFOR...

Страница 2: ...URNS DO NOT USE CHEMICALS OR FLUIDS TO IGNITE THE FIRE DO NOT LEAVE THE STOVE UNATTENDED WHEN THE DOOR IS SLIGHTLY OPENED DO NOT BURN GARBAGE FLAMMABLE FLUID SUCH AS GASOLINE NAPHTHA OR MOTOR OIL DO N...

Страница 3: ...nts required for your particular chimney installation For mobile homes see page 13 Assembly Flue Collar Assembly 1 Mount the flue collar to the top of the unit as shown using the 3 5 16 18 x 1 1 2 bol...

Страница 4: ...ION THE BLOWERASSEMBLY IS INTENDED FOR USE ONLY WITHASTOVE THAT IS MARKED TO INDICATE SUCH USE DO NOT ROUTE THE SUPPLY CORD NEAR OR ACROSS HOT SURFACES Step 1 Fix the assembly to the back of the stove...

Страница 5: ...H AIR INTO THE ROOM OR SPACE HEATED SHALL BE PROVIDED WHEN REQUIRED POSITIONING THE STOVE It is very important to position the wood stove as close as possible to the chimney and in an area that will f...

Страница 6: ...section of chimney connector the floor protector should go under it and 2 inches beyond each side To calculate R Values for alternative methods see ALTERNATE FLOOR PROTECTOR CALCULATIONS section in t...

Страница 7: ...nnector must not pass through an attic or roof space closet or similar concealed space a floor or a ceiling For Canadian installations where passage through a wall or partition of combustible construc...

Страница 8: ...nd of the section toward the chimney Any installation with a horizontal run of chimney pipe must conform to NFPA 211 You may contact NFPA National Fire Protection Association and request the latest ed...

Страница 9: ...the draft effect your stove s performance is directly dependent on an adequate draft from your chimney The following recommendations may be useful for the installation of your chimney 1 DO NOT CONNECT...

Страница 10: ...same manufacturer and install the ceiling support package or wall pass through and T section package firestops where needed insulation shield roof flashing chimney cap etc Maintain proper clearance t...

Страница 11: ...ssociation NFPA by having it inspected by a professional Make sure there are no cracks loose mortar or other signs of deterioration and blockage Have the chimney cleaned before the stove is installed...

Страница 12: ...r and a minimum 24 gage ventilated wall thimble which has two air channels of 1 25 4 mm each construct a wall pass through There shall be a minimum 6 152 4 mm separation area containing fiber glass in...

Страница 13: ...ffer smoke roll out when opened or back drafts occur whether or not there is combus tion present 4 Opening a window slightly on a calm windless day alleviates any of the above symptoms 5 The house is...

Страница 14: ...conditions it may rot instead of drying This point cannot be over stressed the vast majority of the problems related to the operation of a wood stove is caused by the fact that the wood used was too d...

Страница 15: ...kindling wood inside the combustion chamber When you have achieved a good bed of hot embers we recommend the following burn procedures HEATING Controlled combustion is the most efficient technique fo...

Страница 16: ...nse in the relatively cool chimney flue of a slow burning fire As a result creosote residue accumulates on the flue lining When ignited this creosote makes an extremely hot fire The chimney connector...

Страница 17: ...o parts have been damaged in which case repairs must be performed immediately Inspect and clean the chimney and connector pipe periodi cally for creosote buildup or obstructions GLASS Inspect and clea...

Страница 18: ...Ventilate and vacate the room to avoid discomfort Once the curing is complete there will be no odor or smoke After re coating portions of your stove remember to follow the curing process as discussed...

Страница 19: ...Ussc 19 REPAIR PARTS Feed Door Assembly...

Страница 20: ...8 ID X 7 8 OD X 1 16 THK 2 9 83274 3 8 16 LK NUT BLACK 2 10 83508 5 16 18 X 3 4 BOLT 1 11 83431 WELD TAB 3 12 83432 5 16 18 X 1 1 2 HX HD C S PL 3 13 83338 5 16 18 LOCK NUT 1 14 25080 LATCH DOOR 1 15...

Страница 21: ...FULL MODEL NUMBER WHICH IS ON THE NAMEPLATE ATTACHED TO THE HEATER WHEN ORDERING REPAIR PARTS ALWAYS GIVE THE FOLLOWING INFORMA TION AS SHOWN IN THIS LIST 1 THE PART NUMBER 2 THE PART DESCRIPTION 3 TH...

Страница 22: ...layer to determine overall R value If the overall R value of the floor protector system is equal to or greater than the floor protector specifications given the alternate is acceptable Definitions Th...

Страница 23: ..._________ Reason for Purchase Alternative Heat Main Heat Source Decoration Cost Other _________________________ What was the determining factor for purchasing your new appliance _______ I have read th...

Страница 24: ...24 Ussc CUT HERE CUT HERE Fold Here Fold Here United States Stove Company P O Box 151 South Pittsburg TN 37380 Fold Here PLACE STAMP HERE...

Отзывы: