24
PC3060 Price Computing Scale User Instructions
F11 rS232
ModE
prin
The scale RS232 protocol will be determined by the
Baud & Pr
tr
settings
tpup
Enable accumulation function, and press M+ key to
send data to printer
Lp50
Enable accumulation function, and press M+ key to
send data to printer
POS
Protocol Type: POS
oFF
RS232 function disable
Cont
Continuous data transmission
StC
Stable data sending continues
tole
do
Protocol Type 1: Toledo
ncie
cr
Protocol Type 2: NCI-ECR
ncig
en
Protocol Type 3: NCI-General
tec
Protocol Type 4: TEC
easy
Protocol Type 5: Easy Weigh
baud
Set baud rate to (1200/2400/4800/9600/19200/38400/
115200)
Pr
8n1
8 data bits, no verify, 1 stop bit
7E1
7 data bits, Even verify, 1 stop bit
7o1
7 data bits, Odd verify, 1 stop bit
Menu
Sub-Menu
Description
Press the
UNITS
key to choose kg or lb unit in the setting mode, capacity will be
shown in kg or lb values.