AWT35-100107 Rev AB
18/30
AUTO
AUTO
= if selected, acts as the AVERAG
mode and after each NLD.RNG zero, any
loads over (NLD.RNG), is hold on the
display.
AVG.TIM
Average
1
~
60
5
Averages weights in Hold mode for: 1~60
seconds.
STB.TIM
Stable
3*AVG.TI
M
~
255
15
Allows 3*(AVG.TIM) ~ 255 seconds for
stable conditions to be met in Hold mode.
HLD.TIM
Hold
0
~
65535
0
Displays Hold mode weight for:
0
= until HOLD key pressed;
1~65535 = the scale exits the Hold mode
after 1 ~ 65535 seconds.
HLD.RNG
Oscillations
0
~
255
5
Sets the weight oscillation range that can
be averaged in Hold mode:
0 = any weight range can be averaged;
1
~
255
= only the weight which oscillates
within the 1 ~ 255 div range can be
averaged.
NLD.RNG
No Load
Detected
Range
1
~
255
10
Sets the weight range that the indicator
considers as the Zero range for the
relevant function e.g. Auto Hold Mode.
1
~
255
= the range of weight is 1 ~ 255
div.
Note: It must be above the Config-
A.OFF.T
0
~
255
3
Sets the auto off time:
0 = disabled;
1
~
255
= if in standby mode for 1~ 255
minutes, turn the scale off.
LCD.BLT
AUTO
AUTO
Sets the LCD backlight:
Auto:
if in standby mode for 10 seconds,
turn the display backlight off.
OFF
:
always off;
ON
:
always on.
OFF
ON
LCD.CST
CST1-5
CST5
Adjusts the LCD contrast