AWT35-100107 Rev AB
15/30
5 Menus
There are four menus that allow you to configure, enable, or execute specific functions or options.
•
User and Diagnostics Menu,
•
Calibration Menu,
•
Service Configuration Menu,
.
5.1 User Menu
In the User Menu there are various submenus available to configure specific sections of the scale
operating modes, including the print and communication settings.
In general weighing mode, press the
HOLD
and
ZERO/ON/OFF
keys. Release the keys when the
“USER” message pops up to open the User Menu.
Navigate the menu using the keys, press the
TARE
key to confirm or the
ZERO/ON/OFF
key to cancel the operation / exit the menu.
5.1.1 User Options
USER
SubMenu1 SubMenu2
Option
Default
Description
RESET
NO
NO
NO
Returns the USER parameter to the factory
setting
YES
RS232
Port
(com1)
BAUD.RT
600
9600
Sets the baud rate of com1
1200
2400
4800
9600
19200
BYT.FMT
8N1
8N1
Sets the data bits format of com1
7O1
7E1
7O2
7E2
OUT.MOD
NONE
PRTCMD
Sets the output mode of com1:
NONE = no communication;
CONT = continuous output;
PRINT = press PRINT key for output;
CMD = via print format command only;
PRT.CMD
= output with PRINT key and
print format command (
;
STABLE = output when the weight stable
condition is met (See
Note:
when set to
PRINT or CMD mode,
the weighing must be in stable condition.
CONT
CMD
PRTCMD
STABLE