background image

Bray Series 6P

Operation and Maintenance Manual

9

Bracket Information

The Series 6P is supplied with a standard adjustable 

bracket for NAMUR mounting. 

NOTICE

Care must be taken when assembling the two top 

brackets to the bottom brackets. Please refer to  

Figure 5

 for proper placement. Failure to do so will 

cause the positioner to be misaligned to the actuator 

shaft causing binding and poor performance.

1.  Standard actuator stem height 

(H)

 is .79” 

(20mm), 1.18” (30mm), or 1.96” (50mm).  

After checking “H” 

(Figure 6)

, assemble with 

the bracket as shown in 

Figure 5

.

2.  Set rotation position of the actuator stem at the 

zero point. For a Spring Return Actuator, Zero 

point is the position at which the actuator rests 

with no supply pressure. If a Double Acting 

actuator is used, check actuator stem’s rotation 

direction (clockwise or counter-clockwise) by 

supplying pressure.

3.  Attach the Series 6P to the bracket as shown in  

Figure 8

. This sets the alignment of the main 

shaft and the center of the actuator stem. 

NOTICE

Misalignment of the main shaft and the actuator stem 

lowers the Series 6P’s sensitivity, because too much 

side force will be imposed on the feedback shaft. 

4.  Tighten the Series 6P base and the bracket  

hex-headed bolts to the actuator after checking 

the position using the supplied Hex Head Bolts, 

Spring Washers, and Lock Washers. M5 or 

#10-32 bracket to actuator mounting screws are 

supplied depend-

ing on specified 

actuator drilling

H: 20, 30

H: 50

50

20

30

H: 20, 30

NAMUR TYPE  50

H: 50

NAMUR TYPE  30

NAMUR TYPE  20

H

Counter-Clockwise

Clockwise

Figure 6

Figure 7

Figure 5

Figure 8

Содержание 6P Series

Страница 1: ...SERIES 6P Pneumatic Positioner OPERATION AND MAINTENANCE MANUAL R CONTROLS...

Страница 2: ...s a potential situation which if not avoided may result in an undesirable result or state including property damage CAUTION Beware of moving parts when positioner is operated CAUTION Do not dismantle...

Страница 3: ...duction 4 Product Description 4 Manufacturer Warranty 4 Operation Logic 5 Label Description 6 Specifications 6 Parts and Assembly 7 Dimensions 8 Installation 8 Bracket Information 9 Piping Connection...

Страница 4: ...ese products are used for the purposes for which they were designed and manufactured Bray does not warrant its products against chemical or stress corrosion or against any other failure other than fro...

Страница 5: ...poppet 14 to seat and vent the outer chambers 10 As the actuator s inner pressure increases the actuator stem 8 rotates When the signal input pressure decreases the spool 1 moves to the left reversin...

Страница 6: ...ection 1 4 NPTF Gauge Connection 1 8 NPTF Protection IP66 Cam Linear Optional Reverse Acting Ambient Temperature Ranges Std 4 F to 158 F 20 C to 70 C High 4 F to 248 F 20 C to 120 C Low 40 F to 158 F...

Страница 7: ...7 Parts and Assembly Figure 2 ZEROADJUSTMENT CONNECTOR COVER FEEDBACKSHAFT PILOTVALVE SPANADJUSTMENT INPUTBELLOWS Auto ManualAdjustment CAM DOMEGEAR SIGNALIN SUPPLYIN OUTPUT1 OUTPUT2 Auto Manual Adjus...

Страница 8: ...for hex head bolts Before installation be sure to check for the following installation components 1 1 Main Body 2 1 bracket set 3 pcs 3 8 pcs of hex head bolt M8 x 1 25P w washers 4 12 pcs of M7 alle...

Страница 9: ...ator rests with no supply pressure If a Double Acting actuator is used check actuator stem s rotation direction clockwise or counter clockwise by supplying pressure 3 Attach the Series 6P to the brack...

Страница 10: ...ng Return Actuator When mounting on the Bray S93 Spring Return Actuator OUT 1 should be connected to port A left port when facing the ports and OUT 2 should be plugged This generates increasing pressu...

Страница 11: ...Span 1 After setting the Zero Point increase the signal pressure to 15 psi Loosen the locking screw slightly and rotate or turn the Span Adjustment Screw clockwise or counter clockwise until the actu...

Страница 12: ...been dis placed Hunting may occur when the positioner is attached to a very small capacity actuator ex Bray Series 92 93 size 48 In such case install an output orifice for OUT 1 and OUT 2 per the foll...

Отзывы: