GB
version
E
Copyright Bravilor Bonamat B.V.
10
1.0
7.
CORRECTING MALFUNCTIONS
If the device is not operating (correctly), consult
the following checklist to learn whether you can
resolve the problem yourself. If this is not the
case, please contact your dealer.
READ!
(700.403.347)
WARNING
n
Always check whether the malfunction is of a
mechanical or electrical nature. Work on and
repairs to the electrical system and the
cooling system are strictly reserved for
service engineers with the appropriate
authorisation and training.
7.1
General
LIST OF MALFUNCTIONS
Symptom:
Possible cause:
Actions:
1. Nothing appears in
th di l
The plug is not put into the socket.
Put the plug into the socket.
the display.
The mains voltage is interrupted.
Switch on the mains voltage.
2. The device no
longer switches off
and/or no longer
hill tl
The airflow to the condenser (rear)
has become dirty owing to dust
having been drawn in.
Use a vacuum cleaner to clean the
grille at the rear.
chills correctly.
The grille is (partially) covered.
Ensure that the grille is free from
obstacles that might impede the
airflow.
The device is being chilled
inadequately because it has been
installed too close to a source of
heat.
Locate the device in a position
where it can draw in cool air.
3. The water has an
unusual taste when
it is drunk.
The filter requires replacing.
Replace the filter, see § 5.3.
Verify the filter settings and change
these if necessary.
The cold
−
water reservoir
requires cleaning.
Clean the reservoir, see § 5.3.
The device has not been used for a
long period of time.
Replace the filter and clean the
reservoir, see § 5.3.
4. The red lamp
alongside the
di l (fi 1 C1)
The period for the effective life of the
filter has elapsed (6 months).
Replace the filter, see § 5.3.
display (fig. 1 , C1)
is flashing.
The set number of litres of P2 has
been reached, see § 6.1.2.3.
Replace the filter, see § 5.3.