Page 38
Maintenance and Lubrication
All listed inspection, lubrication and maintenance
procedures should be repeated at 750 cycle inter-
vals following the scheduled 4500 cycle mainte-
nance procedures. These intervals are a general
guideline for scheduling maintenance procedures
and will vary according to lift use and conditions.
Lifts exposed to severe conditions (weather, envi-
ronment, contamination, heavy usage, etc.) may
require inspection and maintenance procedures to
be performed more often than specified.
Maintenance Indicator:
The Lift Ready green
LED mounted on top of the pump cover will change
color to yellow after every 750 cycles. The yellow
LED will not affect the functions of the lift, but is a
reminder to complete necessary maintenance and
lubrication procedures. Once the lift has been
serviced, press the CYCLE button (located below
LCD display on the control board) until the Lift
Ready LED changes back to green. The CYCLE
button also clears the lift cycle count (since last
service) but not the lifetime cycle count.
Discontinue lift use immediately if maintenance
and lubrication procedures are not properly per-
formed, or if there is any sign of wear, damage
or improper operation. Contact your sales repre-
sentative or call BraunAbility
®
at 1-800-946-7513.
One of our national AfterSales representatives
will direct you to an authorized service technician
who will inspect your lift.
See the Maintenance/Lubrication Schedule for recommended applications per number of cycles.
Specified (recommended)
Available
BraunAbility
®
Lubricant
Type
Lubricant
Amount
Part No.
LO - Light Oil
DE - Door-Ease
SG - Synthetic Grease
15807
15806
28598
1.68 oz.
Mobiltemp SHC32
Light Penetrating Oil
(30 weight or equivalent)
LPS2, General Purpose
Penetrating Oil
16 oz.
Aerosol Can
Door-Ease
Stick (tube)
Stainless Stick
Style (tube)
12.5 oz.
Tube
Synthetic Grease
(Multipurpose)