Page 7
Specifications
The lift must be installed, operated, and maintained as detailed in applicable manuals.
Any use of equipment other than instructed in this manual is prohibited.
The 500 kg (1102 lb) lift capacity Millennium-2 series lifts have completed 15,600 cycles with a 500 kg
load and a static load test with a 1050 kg (2315 lb) load.
The specifcations below reflect CE standards. Lifts meet or exceed these requirements.
Operating Temperature
This equipment will operate in its intended ambient at a minimum between -30ºC and +65ºC.
Relative Humidity
This equipment will operate correctly within an environment at 50% RH, at 40ºC.
Altitude
This equipment will operate correctly up to 1000 m above mean sea level.
Sound Pressure Level
The emission sound pressure level at the operator’s position is expected not to exceed 70 db(A).
Transportation and Storage
This equipment will withstand, or has been protected against, transportation and storage temperatures
of -25ºC to +55ºC, and for short periods of up to +70ºC.
The lift has been packaged to prevent damage from the effects of normal humidity, vibration, and shock.
Section Modulus (S) (IN˄3)
: 4.363333333
L1100IB4061RP-2
12 VDC
500 kg (1102 lb)
213 kg (469 lb)
Maximum
Load Capacity
Power
Requirement
Lift
Weight
Lift
Model