background image

 

 
 
 
 
 
 
 
 
 
 
 
 

A. Installation 

 

B. Operating 

instructions 







Содержание MULTIQUICK 3 K 600

Страница 1: ...A Installation B Operating instructions E N G L I S H...

Страница 2: ...2 E N G L I S H...

Страница 3: ...art B Operating instructions are included as Adobe PDF file on the CyberView X MS CD The file will be installed with the driver and will be available on the computer after the installation without the...

Страница 4: ...rivers PC and Mac CD with Adobe Photoshop Elements and Adobe Photoshop Album IMPORTANT NOTES The reproduction of this manual in whole or in part without the manufacturer s written permission is prohib...

Страница 5: ...he scanner or the power adapter emits unusual sounds or odors or if smoke escapes switch of the scanner immediately and disconnect it from the power outlet There is the risk of fire in case of continu...

Страница 6: ...r if it is excessively stretched or twisted there is the risk of fire or electrical shock If the power cord insulation is damaged or if wires are blank contact the manufacturer s after sales service i...

Страница 7: ...5 to 76 relative humidity non condensing If the scanner was stored or transported in cold temperature and then brought into a warm humid environment condensation may occur Allow the scanner to fully a...

Страница 8: ...rView X to start the installation wizard Follow the on screen instructions to complete the installation 4 There may be additional test software products on the installation CD If they are installed fo...

Страница 9: ...order to install the driver 5 There may be additional test software products on the installation CD If they are installed follow the on screen instructions to complete installation INSTALLING THE SCA...

Страница 10: ...evenly with slides CS magazine It is recommended to use the original CS system reflecta Braun exclusively Other CS magazines or CS frames may lead to disturbances Universal magazine Use only magazines...

Страница 11: ...ig 3 Fig 3 As an alternative you can use the arrow buttons in the CyberView X MS GUI to move the magazine Previewing individual slides Insert the slide into the slide viewer at the side of the scanner...

Страница 12: ...are When using Adobe Photoshop Elements select File Import CyberView X MS to open the TWAIN driver Information about Adobe Photoshop Album Please refer to the Adobe Photoshop Album manual for addition...

Страница 13: ...ing Single prescan Multi prescan Settings for the scanning process Define the resolution the color depth and the quality of the slide scan If you do not specify values the settings defined in the Pref...

Страница 14: ...5 1 2400 16 42 2 3000 16 66 2 4 3600 16 94 3 3 For the jpg file format the quality BEST was used to store the scans listed above Starting the scan process Select Scan Current Frame to scan the slide...

Страница 15: ...ed to the opened application software Exiting the program After scanning the slides the images are transferred to the application software e g Adobe Photoshop Elements or stored to the specified stora...

Страница 16: ...ou can define to transfer the scanned data to the calling program or directly to the hard disk When CVX is started as independent program the data can be stored to the hard disk only see 1 1 1 Scannin...

Страница 17: ...first three menu items of the Scan sub menu are displayed only when CVX is started as TWAIN driver In contrast to the other menu items the corresponding scan is transferred to the program where CVX wa...

Страница 18: ...Enter the name of the first image in the Base File Name field Select the file type If the image is stored as JPG file select the quality of the image in the JPEG Quality field The images are numbered...

Страница 19: ...s and the scans Note for the color depth Please note that various programs cannot work with a 16 bit color depth Note for the scan mode When using the Quality option the scan will be slower resulting...

Страница 20: ...matically for the pre scans and a scan offset to position the actual slide section Please note that the x y values for the offset must correspond to the coordinate values as required by Adobe Photosho...

Страница 21: ...iew window the pre scan is magnified Zoom Out When you click in the preview window the pre scan is reduced Rotate 90 Left The preview is turned 90 degrees counter clockwise Rotate 90 Right The preview...

Страница 22: ...gs Note The Reset All button restores the settings of all three areas In order to only reset the changes of the current area press the button with the green arrow Press the OK button to confirm your e...

Страница 23: ...orresponding setting between Fine for little change and Coarse for great change Prior to correcting the scan set the area and the degree Now click on one of the corrected images to accept the correcti...

Страница 24: ...st saturation and color CMY or RGB of the image can be adjusted with the sliders or by entering the values in the corresponding fields You can use the buttons with the magnifying glasses to zoom in an...

Страница 25: ...close look at the modifications You can use the three buttons with the pipettes to set a black gray or white eye drop for the image with a simple mouse click You can also use the sliders below the ga...

Страница 26: ...correct the exposure already when scanning If your images to be scanned have a color imbalance you can make corrections already when scanning The same applies for dark images increase the three colors...

Страница 27: ...anual in CVX Update Firmware You can upgrade the firmware version this menu item is necessary to upgrade the firmware installed in the scanner in case of software upgrades After selecting this menu it...

Страница 28: ...e best results are achieved with the Generic setting Example With a positive film slides select Positive Generic Generic Positive In the following the icons and the corresponding menus are listed San...

Страница 29: ...meant as an example 2 Preview window The following settings and information are available in the preview window When selecting the scan area you can select several areas at the same time Click on this...

Страница 30: ...Preview Flip Vertical Scan Revert Selecting the ruler units in the Preview window You can specify the measurement unit in in inch US cm centimeter or px Pixel by clicking on the top left corner The un...

Страница 31: ...the exposure in the bottom right corner 3 Active Frame Setting You can select the scan resolution the color depth and the scan quality of the currently scanned active image You can also set the size...

Страница 32: ...32 E N G L I S H The Advanced mode displays additional information about the planned output Changes in these two entry areas result in corresponding changes of the other values...

Страница 33: ...m the marked check boxes below the images When pre scanning more than six images you can use the left right arrow buttons to scroll through the images Use the check boxes to select the images to be sc...

Страница 34: ...Visit our home page for support and driver updates The Adobe Photoshop Elements and Adobe Photoshop Album products are updated by Adobe Please contact the following web site if you need support for t...

Отзывы: