34
CLEAN&RENEW STATION
Shaving system
is still wet
after cleaning
program
has been
completed.
1. Drain of the
Clean&Renew station
is clogged.
2. Cleaning cartridge
has been used for
quite a while.
1. Clean the drain with a wooden
toothpick. Regularly wipe the
tub clean.
2. The ethanol proportion has
decreased while the oil
proportion has increased.
Remove residue with a cloth.
Cleaning does
not start when
pressing the
start button.
1. Shaver is not placed
properly in the
Clean&Renew station.
2. Cleaning cartridge
contains not enough
cleaning fluid (display
lights red).
3. Appliance is in
stand-by mode.
1. Insert shaver into the
Clean&Renew station (contacts
of the shaver need to align with
contacts in the station).
2. Insert new cleaning cartridge.
3. Press start button again.
Increased
consumption of
cleaning fluid.
Drain of the
Clean&Renew station
is clogged.
– Clean the drain with a wooden
toothpick.
– Regularly wipe the tub clean.