Page 8
Inner Roll Stop Adjustment
CAUTION
Do not adjust inner
roll stop clevis link.
Clevis link adjust-
ment may result in
lift damage.
Do not adjust inner roll
stop clevis link at this time!
Clevis link adjustment is
not required unless extra
usable platform length is
needed.
Inner Roll Stop
Clevis Link
Adjust inner roll stop
fl
oor level
position as detailed in the fol-
lowing procedures. Then, adjust
the clevis link as detailed on
page 10 (only if necessary).
1. Raise the lift platform fully (
fl
oor
level) using the control pen-
dant. If the inner roll stop rests
solidly on vehicle
fl
oor with 7°
maximum angle (relative to the
platform), do not adjust the inner
roll stop.
Lower the platform to ground
level. If the angle of the inner
roll stop does not restrict the
usable platform length for the
wheelchair passenger, disregard
inner roll stop adjustment pro-
cedures. See Photo F on page
10. Refer to the following proce-
dures if adjustment is required.
2. Using the control pendant,
raise
the lift platform fully to
fl
oor level.
See Photo C.
Note: Lift will operate indepen-
dent of handrail or outer barrier
position. Deployment is not
necessary for these procedures.
Floor Level
Raise
to Floor
Level
B
C
Floor Level and Inner Roll Stop Adjustments
Valve
Pump
Handle
Figure A
O
P
E
N
C
L
O
S
E
OPEN
VALVE
CLOSE
O
P
E
N
C
L
O
S
E
VALVE
Manual Hand Pump
Hand Pump