Setting current time of day
User programming
User Programming Mode Steps (Refer to chart above for user mode indications)
1. Press the Up and Down buttons for five seconds while valve is in service. Display will enter
programming mode. (Note: Timer will discard any changes and exit programming mode if
any button is not pressed for sixty seconds.
2.
Set Day Override:
This setting specifies the maximum number of days between regenera-
tion cycles. System will regenerate regardless of usage if the days since last regeneration
cycle equals the day override setting. For dealkalizer filters, this setting is factory set at 3.
This will allow for the correct amount of water usage allowed between regeneration cycles.
Setting Current Time / Day
1. Press either the Up or Down buttons to adjust current time of day by one digit. Push and
hold either up or down set button to adjust current time of day display by several digits.
Start-Up Procedure
Abbreviation
Parameter
Description
DO
Day Override
The timer’s day override setting
RT
Regeneration Time
The time of day that the system will
regenerate (meter delayed, timeclock,
and day-of-week systems)
H
Feed Water Hardness
The hardness of the inlet water—
used to calculate system capacity for
metered systems
RC
Reserve Capacity
The fixed reserve capacity
User Programming Mode Options