Brassmaster PLUS STS-400 Скачать руководство пользователя страница 2

Installation Procedure 

1. 

Identify installation location for water softener. 

Piping should be such that all household 

water, with the exception of outside hydrants, flows through filter. This system and installa-

tion must comply with state and local laws and regulations. 

2. 

Connect water piping. 

This unit has been supplied with a manually operated bypass device 

which enables the filter to be isolated from the water service lines for maintenance and ser-

vice, and also maintain the continuity of the water supply when the filter is disconnected.

 

Important: Make all sweat-solder connections within 6 inches of  filter before applying 
threaded fittings to supplied bypass valve. Overheating may cause damage to valve. 

Turn 

supplied bypass valve to “Bypass” position and make connections to household water lines. 

Leave unit in “Bypass” position until startup procedure. 

3. 

Connect drain line. 

Remove barbed drain line fitting from parts bag. Apply thread seal 

tape to threads and turn into the female threaded opening on the back side of the control 

valve. Connect 5/8” drain line (supplied in parts bag) to barbed end of drain line fitting and 

run to a nearby drain.  

IMPORTANT: It is highly recommended that a hose clamp be used to secure tubing to 
drain fitting to ensure tubing from being removed during elevated pressure situations. 

Be sure not to submerse drain line end into drain, as an 1 1/2” minimum air gap must be 

maintained to prevent potential backflow hazard. Firmly secure at drain while maintaining a 

minimum 1 1/2” air gap (See detailed drawing on back side of piping diagram). 

4. 

Connect brine line.

 Connect 3/8” brine line (supplied in parts bag) to fitting on brine tank, 

and on the control valve. Tighten both fittings with an adjustable wrench. 

5. 

Install brine tank overflow line. 

Install overflow fitting (supplied in parts bag) into hole in 

side of brine tank. An owner-supplied overflow line should then be attached and run to a 

nearby drain. 

Failure to run overflow line could cause flooding and water damage should 

the brine tank overflow. 

 

6. 

Connect  to  electrical  power  source. 

Connect  power  cord  to  a  separate  120v,  15  amp, 

ground fault interrupt (GFI) outlet.  

Proceed to start-up procedure. 

 
 
 
 
 
 

Note:   This system is not intended to be used for treating water that is microbiologically  

 

unsafe or of unknown quality without disinfection before or after the system. 

Содержание PLUS STS-400

Страница 1: ...ster Plus Technical Video Library http watercontrolinc com residential technical support residential technical videos BrassMaster technical videos demonstrate how to set up or remove the control modul...

Страница 2: ...d in parts bag to barbed end of drain line fitting and run to a nearby drain IMPORTANT It is highly recommended that a hose clamp be used to secure tubing to drain fitting to ensure tubing from being...

Страница 3: ...d let go display will indicate BF Brine Fill cycle Allow timer to fill the brine tank for the entire time on the display The unit will advance to the service position when completed Push extra cycle b...

Страница 4: ...or dealkalizer filters this setting is factory set at 3 This will allow for the correct amount of water usage allowed between regeneration cycles Setting Current Time Day 1 Press either the Up or Down...

Страница 5: ...o next option For dealka lizer filters this setting is factory set at 25 This will allow for the correct amount of water usage allowed between regeneration cycles 5 Set Fixed Reserve Capacity Press th...

Страница 6: ...using a broom handle or similar rod Carefully pound it into the salt and the pellets will collapse After loosening the salt pellets wait 2 hours and start a regeneration A second recharge may be neede...

Страница 7: ...DISCLAIMS ANY AND ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE WHAT IS NOT COVERED BY THESE WARRANTIES 1 Conditions and dama...

Страница 8: ...Water Control Corporation 7150 143rd Ave NW Ramsey MN 55303 Phone 1 866 405 1268 Fax 763 427 5665 www watercontrolinc com 0919...

Отзывы: