background image

 CAUTION: DO NOT INSTALL THIS PRODUCT UNTIL YOU READ 

AND UNDERSTAND ALL INSTRUCTIONS. FAILURE TO FOLLOW 
THESE INSTRUCTIONS MAY RESULT IN PERSONAL INJURY, 
PROPERTY DAMAGE OR PRODUCT FAILURE. 

 

BrassCraft’s Sure2Connect 1/4-turn stop features a push connect 
inlet with a new patented verification technology. The Sure2Connect 
valve is compatible with copper, CPVC and PEX and easy to install. 
It requires no special tools, no measuring, marking, soldering or 
glue for a watertight seal. Simply PUSH the stop onto the tube.  
LOCK the verification clip into place. Once you hear the “click”, 
your installation is DONE.  It’s the connection you can see, hear 
and feel when the stop is properly installed. Manufactured from 
advanced engineered polymer, the Sure2Connect valve is corrosion 
resistant to harsh chemicals and harsh water conditions. This 
product also features 1/4 activation which means with a 90° turn 
of the valve handle, you are able to stop or start the flow of water.  
Sure2Connect valves are 100% leak tested.

INSTALLATION INSTRUCTIONS

Do not reuse, inspect annually, replace if damaged, deterioration or corrosion is 
detected. Failure to do so may result in product failure and property damage. 
Manufacturer assumes no responsibility for failure due to improper installation.
Be sure to shut off water before starting.

 CAUTION: FOR USE WITH WATER IN ACCESSIBLE LOCATIONS ONLY.
 CAUTION: DO NOT SWEAT WITHIN 12 INCHES OF A G2

 1/4 TURN VALVE.

 CAUTION: DO NOT USE G2 OR MULTI-TURN VALVES ON RECIRCULATION

SYSTEMS EXCEEDING 115˚ F. 

 CAUTION: DO NOT USE WITH CONNECTORS HAVING A SOLID BRASS CONE 

OR BULL NOSE DESIGN - FRACTURES CAN DEVELOP. 

 CAUTION: VALVE MUST BE USED IN THE FULLY OPENED OR FULLY CLOSED POSITION.
 CAUTION: OUTLET MUST BE CAPPED IF VALVE IS BEING USED AS A 

TERMINATION POINT.

For Use with Copper, PEX, and CPVC only

1.  Make sure that the tubing is cut square 

and free from any damage including 

dings, dents, and burrs, and free of 

paint, putty or any other debris that may 

prevent the connection from sealing 

properly. 

2.  You will need a minimum of 2- 5/8 in. 

of exposed tubing to accommodate the 

valve and shallow escutcheon. 
(Notes: 1-5/8 in. for valve, 1/2 IN. for shallow escutcheon, 1/2 in. for removal tool 

= total minimum of 2-5/8 in. Adjust length for deeper Escutcheon).

3.  Slide the flange onto the tube.
4.  Push the valve onto the tubing until you 

feel a strong resistance. Valve is properly 

seated when you cannot push the valve 

any further onto the tubing. A tube 

Sure2Connect

®

 Shut-Off Stop

 

support has been pre-installed for PEX 

installations and will self-align with the 

tubing. Although the tube support is not 

required for copper and CPVC tubing, do 

not remove it.  The tube support will not 

interfere with the installation.

5.  Push down on the clip near the valve 

inlet until it is flush with the valve body 

and you hear it “click” into place. If the 

clip does not fully engage, the valve 

is not completely installed. Push the 

valve farther onto the tube and retry 

engaging the clip.

6.  Attach the water connector to the 

fixture according to the manufacturer’s 

instructions.  

7.  Make sure the valve is in the off position. Then, turn the main water supply back 

on, and then re-open the valve.

Tools Needed For Installation: 

  

•Tube Cutter   •Reamer   •Sandpaper •Deburring Tool   •Adjustable Wrench

TO REMOVE:

1.  Turn water system off and ensure system is depressurized. Remove supply line 

and drain remaining water from tube. Rotate the valve until clip openings are 

accessible.

2.  Position the tips of the needle nose 

pliers against the base of the clip and 

gently squeeze and push up at the 

same time until the clip disengages.

3.  Position a 5/8 in. open-ended wrench 

or a removal tool (with the smooth 

end against the removal collar) around 

the tube. Place removal tool over the 

pipe and use the tool to push the 

removal collar toward the valve body 

at the same time pulling valve body 

off of pipe. Pushing the removal tool 

toward valve will help release locking 

mechanism.

Tools Needed For Removal

:

 Needle Nose Pliers 

 Removal Tool or 5/8 in. open end wrench

 

 

425.05   Rev. 11/19

INSTALLATION INSTRUCTIONS (CONTINUED)

REMOVAL TOOL

REMOVAL COLLAR

Brasscraft Manufacturing Co., 39600 Orchard Hill Place Novi, Michigan 48375-5331 

TOLL-FREE: 877.272.7755   FAX: 248.305.6011   www.brasscraft.com

Manufacturer assumes no responsibility for failure due to improper installation.

©2019 Brasscraft Manufacturing Company, Novi, MI 48375-5331 U.S.A.

All Rights Reserved. www.brasscraft.com Designed, Machined and Assembled in the U.S.A. 

BrassCraft

®

 brand is a trademark of Brasscraft Mfg. Co. 

El fabricante no asume ninguna responsabilidad si la instalación no se hace de acuerdo al instructivo.

Diseñado, Maquinado y Ensamblado en E.U.A. BrassCraft

®

 brand es una marca registrada de Brasscraft Mfg. Co.

©2019 Brasscraft Manufacturing Company