DANGER:

 DO NOT USE motorized 

equipment or other sources of 

combustion to dissipate gas vapors.  

Motorized equipment can ignite gas 

vapors causing fire or explosion 

which may result in property 

damage and/or personal injury 

including death. (Figure N)

DANGER:

  Fuel gases are colorless, 

tasteless and in its pure state, odorless.  

They are odorized (rotten egg smell) so that their presence can be detected.  LP 

gases are heavier than air and dissipate slower than natural or manufactured 

gases. LP gas, if released in quantity, will accumulate in low-lying areas such as 

a basement or crawl space. 

 

THIS PLUS

®

 EXCESS FLOW VALVE (included with the connector) IS NOT 

DESIGNED TO ACTIVATE IF ANY OF THE FOLLOWING CONDITIONS ARE PRESENT:
•      

There are small leaks such as pin hole leaks or lesser leaks caused by cracks 

or loose connections that do not increase the gas flow above normal operating 

capacity of the appliance.

•      The gas appliance malfunctions or the user fails to shut off gas burners.
•      There is foreign matter, such as pipe thread sealant, lodged in the valve.
•      The manual gas shut-off valve is partially opened, or there is a pipe break or 

damage that has occurred upstream of the PLUS

®

 excess flow valve that 

prevents sufficient gas flow through the valve.

•      There is insufficient gas flow from an improperly sized gas piping system 

upstream of the PLUS valve.

•      The gas flow through the valve is in the wrong direction.  The excess flow valve 

responds to gas flow in one direction only (see product label).  The valve must be 

installed so that the arrows point in the direction of gas flow.

•      The PLUS valve is damaged, exposed to fire or improperly installed. 

WARNING:

 Replace the PLUS

®

 valve if it has been damaged or exposed 

to fire.

WARNING:

 PLUS

® 

EXCESS FLOW VALVE is only intended for use with 

packaged connector.

PSC1106 Range & Dryer Kit Contents:

• 

1/2 in. OD x 48 in. Coated Stainless Steel Gas Connector

• 

PLUS

®

  Excess Flow Valve -1/2 in. MIP (tapped 3/8 in. FIP)

• 

1/2 in. MIP (tapped 3/8 in. FIP) steel fitting

• 

1/2 in. FIP steel fitting

• 

3/8 in. MIP steel fitting

• 

3mil leak detection solution

• 

3mil pipe thread sealant

PSC1107 Professional Range & Furnace Kit Contents:

• 

5/8 in. OD x 48 in. Coated Stainless Steel Gas Connector

• 

PLUS

®

  Excess Flow Valve - 3/4 in. MIP

• 

3/4 in. MIP (tapped 1/2 in. FIP) steel fitting

• 

1/2 in. MIP steel fitting

• 

3mil leak detection solution

• 

3mil pipe thread sealant

325.04 Rev. 11/19

Fig. N

Brasscraft Manufacturing Company, 39600 Orchard Hill Place Novi, Michigan 48375-5331 

TOLL-FREE: 877.272.7755   FAX: 248.305.6011   www.brasscraft.com

©2019 Brasscraft Manufacturing Company

Manufacturer assumes no responsibility for failure due to improper installation. 

©2019 Brasscraft Manufacturing Company, Novi, MI 48375-5331 U.S.A. All Rights Reserved. 

www.brasscraft.com Designed, Machined and Assembled in the U.S.A. BrassCraft

®

 brand is a trademark of 

Brasscraft Mfg. Co. 

El fabricante no asume ninguna responsabilidad si la instalación no se hace de acuerdo al instructivo. Diseñado, 

Maquinado y Ensamblado en E.U.A. BrassCraft

®

 brand es una marca registrada de Brasscraft Mfg. Co.

Содержание CSSL

Страница 1: ...or is not properly sized to the application the Safety PLUS connector may not activate in the event of a gas line rupture or disconnect If the Safety PLUS gas connector is undersized for the appliance it may activate prematurely restricting gas flow during normal operation of the appliance 4 Finally select the connector with the end fittings that match the outlet of your manual gas shut off valve ...

Страница 2: ...nnections CAUTION DO NOT apply pipe thread sealant or tape to flare ends of fittings or valves Figure I Sealant and tape will prevent this connection from sealing properly 4 If not already installed thread manual gas shut off valve onto gas supply stub out Using one adjustable wrench to stabilize the gas supply stub out wrench tighten valve with second wrench 5 Inspect the brass Safety PLUS excess...

Страница 3: ... responds to gas flow in one direction only see product label The valve must be installed so that the arrows point in the direction of gas flow The Safety PLUS valve is damaged exposed to fire or improperly installed WARNING Replace the Safety PLUS valve if it has been damaged or exposed to fire WARNING Safety PLUS EXCESS FLOW VALVE is only intended for use with packaged connector PSC1106 Range Dr...

Страница 4: ...acto indicada como capacidad de entrada La etiqueta del fabricante ubicada cerca de la entrada de gas del artefacto incluirá esta información Vea la Figura B Si no está seguro de la capacidad de entrada correcta del artefacto póngase en contacto con el fabricante 3 Seleccionar el conector de gas Safety PLUS con una capacidad similar pero SUPERIOR a la capacidad nominal de entrada del electrodomést...

Страница 5: ... al fuego El fuego puede dañar el conector y la válvula tornándolos inseguros para su uso Fig F Fig G Fig E INSTALACIÓN ADVERTENCIA NO CONECTE LA VÁLVULA DE SOBRE FLUJO SAFETY PLUS DIRECTAMENTE AL ARTEFACTO La válvula Safety PLUS debe instalarse entre la línea de alimentación de gas y el conector flexible de gas Si se instala directamente en la entrada de gas o en el artefacto la válvula Safety PL...

Страница 6: ...rajaduras o conexiones flojas que no aumentan el flujo del gas por encima de la capacidad normal de operación del artefacto Desperfectos en el funcionamiento del artefacto a gas o el usuario se olvida de apagarlo Materiales extraños tal como sellador para roscas de tuberías atascado en la válvula Llave de paso general parcialmente abierta o una rotura o daño en la cañería de gas ubicado antes de l...

Отзывы: