Limited Warranty

Warranty Statement

Brasch Environmental Technologies, LLC warrants gas transmitters, gas detectors, control 
panels and accessories for a period of two years from the date of shipment against defects in 
material or workmanship.  Should any evidence of defects in material or workmanship occur 
during the warranty period, Brasch Environmental Technologies will repair or replace the 
affected product, at its own discretion, without charge.  The company shall not be held 
responsible for any charges incurred with removal or replacement of allegedly defective 
equipment, nor for incidental or consequential damages. 

Service and Repair Procedures

Our goal at Brasch Environmental Technologies is to produce products that constantly exceed 
the requirements and expectations of our customers.  One of the ways of meeting that goal is 
to produce products that never fail or require service.  However, when we are notified of a 
problem with one of our products, it is our intention to address the problem as quickly and 
efficiently as possible.

Many problems that appear at first to be associated with the product can be solved without 
returning the product.  If you experience a problem and would like to discuss it with a factory 
service technician, you may call the number listed on the product label.  You will be transferred
to a technician specially trained to service that product.  This technician will help you determine
the most efficient way of solving the problem.

If service or repair of your Brasch product becomes necessary, an authorization request for 
returning the product to the Brasch factory must be obtained from our sales office.  If you are 
an end user, please contact your Brasch distributor to initiate this request.  The distributor, after
obtaining a description of the problem, will contact the factory and request a Return Goods Tag
(RGT) number.  This number must be placed in a conspicuous location on the outside of the 
shipping package.  Without this RGT number, Brasch will not accept the shipment.  A brief 
description of the reason for returning the product should be included in the package.  Without 
this description, repair may take longer than necessary.

You may, at the time you request service, request an estimate on the time it will take for repair. 
The Brasch representative will give you an estimate based upon the information you provide. 
Although Brasch Environmental Technologies, LLC will repair and return your product in as 
short a time as possible, Brasch cannot be held responsible for meeting repair estimates. 

IOM02
Rev 1.0 – December 22, 2020

24

Содержание TRNS Generation 2

Страница 1: ...Brasch Environmental Technologies LLC 140 Long Road Suite 101 Chesterfield Missouri 63005 314 291 0440 www braschenvtech com TRNS Generation 2 Installation Operation Manual...

Страница 2: ...Output 14 Connecting the Modbus Output 15 Applying Power For the First Time 15 Installation Diagrams 16 Operation 18 How the Transmitter Senses the Target Gas 18 Factory Default Settings 18 Using the...

Страница 3: ...d in an Unsatisfactory Location 23 Limited Warranty 24 Warranty Statement 24 Service and Repair Procedures 24 Appendix 25 Model Numbers and Descriptions 25 Transmitter Model Number and Description 25...

Страница 4: ...and transmits that signal to the output as either an analog or digital signal The sensor used in the transmitter operates on the electrochemical principle A current is produced when the target gas re...

Страница 5: ...nance Simplified Installation Preconfigured Wiring Factory Calibration Customized Programming Versatile Communication Analog Output via User Selectable Current or Voltage Loop Digital Output via Modbu...

Страница 6: ...Humidity 10 to 90 non condensing Ventilation Control Relays None Internal Alarm None Front Panel Indicators Power green LED Fault yellow LED Display None Selectable Fan Settings None Alert Levels None...

Страница 7: ...h target gas for which Brasch currently produces a transmitter is listed below along with the relevant concentration specifications Carbon Monoxide Full Scale Span 200 PPM Resolution 1 PPM Minimum Acc...

Страница 8: ...er The following table describes the function of each indicator Please refer to the transmitter s front panel label for the indicator s location Front Panel Indicators Indicator Color Description Powe...

Страница 9: ...understand all such notices Types of Notices Three types of notices may be used in this manual to describe the severity of the situation encountered WARNING This notice indicates that conditions exis...

Страница 10: ...provided The circuit must include a disconnect switch located within easy reach of the transmitter Color coded wires exiting the transmitter housing through the top conduit connector are provided for...

Страница 11: ...eference conductor connects to the green wire When using the digital output the positive conductor connects to the brown wire and the negative conductor connects to the blue wire See figures 1 and 2 o...

Страница 12: ...entative of the average gas value in that area These include but are not limited to locations near doorways fans ventilation inlets and outlets and areas with air velocities in excess of 3 3 ft s 1 m...

Страница 13: ...ing cover to gain access to the mounting holes A mounting hole is located at the top and bottom of each housing end wall Find a flat area at least 6 inches high by 6 inches long and place the back of...

Страница 14: ...for connecting the operating voltage to the transmitter Therefore it should not be necessary to remove the front cover from the transmitter when connecting the voltage supply Connect the hot power con...

Страница 15: ...ociated with the transmitter Color coded wires exit the transmitter housing through the top conduit fitting so removal of the front cover should not be necessary At each transmitter the positive condu...

Страница 16: ...Installation Diagrams IOM02 Rev 1 0 December 22 2020 16 Figure 1 Wiring Analog Output Configuration Figure 2 Wiring Digital Output Configuration...

Страница 17: ...IOM02 Rev 1 0 December 22 2020 17 Figure 3 Wiring Remote Sensor Configuration...

Страница 18: ...specified on the order form the following settings will be used to configure the analog proportional output of the transmitter Setting Default Analog Proportional Output Units mA Analog Proportional...

Страница 19: ...he 4 20 mA output mode 0 PPM CO would equal 4 mA while 200 PPM CO would equal 20 mA Follow the instructions supplied with your controller to adjust the controller s input for the proper scaling of the...

Страница 20: ...t contact the transmitter directly The engine should be allowed to operate until a level of the target gas is sufficient to activate the ventilation system Depending upon the volume of the area where...

Страница 21: ...l Technologies recommends testing the detector once every six months to ensure proper response and accuracy Replacing the Sensor The sensor s useful lifetime depends greatly upon its operating conditi...

Страница 22: ...l be approximately 10 years from the original manufacturing date for both Carbon Monoxide and Nitrogen Dioxide sensors The signal is triggered by a clock in the sensor board In the event that the unit...

Страница 23: ...er must be greater than 100 k If these requirements are not adhered to the proportional output will not accurately reflect the concentration of gas measured by the sensor Transmitter Mounted in an Uns...

Страница 24: ...nd would like to discuss it with a factory service technician you may call the number listed on the product label You will be transferred to a technician specially trained to service that product This...

Страница 25: ...ly identify a transmitter once you know the model number Transmitter Model Number and Description Output Type Target Gas CO NO2 CO NO2 Analog TRNS2 CM Analog TRNS2 ND Analog TRNS2 NCM Analog Digital T...

Страница 26: ...v 1 0 December 22 2020 26 UNREG COM UNREG COMM COMM Black White Black Figure 5 Input Power Connections JP2 JP3 4 20 mA 2 10 VDC 1 5 VDC 0 2 1 VDC JP2 JP3 JP2 JP3 JP2 JP3 Figure 6 Proportional Output S...

Страница 27: ...roportional Output Graphs 4 6 8 10 12 14 16 18 20 0 50 100 150 200 Carbon Monoxide Output mA Concentration ppm CO 4 6 8 10 12 14 16 18 20 0 2 5 5 7 5 10 Nitrogen Dioxide Output mA Concentration ppm NO...

Страница 28: ...0 ppm NO 0 5 Sensitivity measured 10 ppm Cl2 100 Sensitivity measured 20 ppm SO2 2 Sensitivity measured 400 ppm CO 0 1 Sensitivity measured 400 ppm H2 0 1 Sensitivity measured 400 ppm C2H4 0 1 Sensiti...

Страница 29: ...merservice braschenvtech com Website www braschenvtech com Revision 1 0 Issue Date December 22 2020 Document Number IOM02 Brasch Environmental Technologies LLC All Rights Reserved Technical Support Co...

Отзывы: