background image

Q U A R K

E N G L I S H

16

(see figure 13).

figure 13

Insert  the  magnetic  outside  rotor  in  the  evaporator  taking

care to accompany it to the end (see figure 14).

figure 14

Install  the outer  spiral.  Slide it  over  the  evaporator  until  its

hexagonal front notch engages with the hexagonal exposed
end of the magnetic outside rotor

 

(see figure 15).

figure 15

Push  the  bowl  towards  the  rear  wall  of  the  unit  until  it  fits

snugly around the gasket and its front fastening hooks are
properly engaged (see figure 16).

figure 16

Use fresh product to chase any remaining sanitizer from the

bottom of the bowl(s). Drain this solution. Do not rinse out the
machine.

7. 4  IN-PLACE SANITIZATION

The In-Place Sanitization prior to starting the machine may
be  performed,  if  needed,  only  as  further  precaution,  in
addition to the Disassembled Parts Sanitization described
before, but never in lieu of it.

Prepare  two  gallons  of  a  warm  (45-60°C,  120-140  °F)

sanitizing solution (100 PPM chlorine residual) according to

your local Health Codes and manufacturer’s specifications.

Pour the solution into the bowl(s).

Using a brush suitable for the purpose, wipe the solution on

all surfaces protruding above the solution-level and on the
underside of the top cover(s).

Install  the  top  cover(s)  and  operate  the  unit.  Allow  the

solution to agitate for about two minutes. Drain the solution out
of the bowl(s).

Use fresh product to chase any remaining sanitizer from the

bottom of the bowl(s). Drain this solution. Do not rinse out the
machine.

8 ROUTINE MAINTENANCE

Daily: 

inspect  the  machine  for  signs  of  product  leaks  past

seals and gaskets. If proper assembly does not stop leaks
around seals or gaskets, check for improper lubrication, worn
or damaged parts. Replace parts as needed.

2

In  case  of  noise  it  needs  to  unplug  the  cooler  and  call  for

service.

3

In case of failure unplug the machine, because unexpected

start again would be possible.

It needs to fix everything back in the initial position after any

repairmen, like screws and covers.

8. 1  MAINTENANCE (TO BE CARRIED 

OUT BY QUALIFIED SERVICE 
PERSONNEL ONLY)

Annually:

  remove  the  panels  and  clean  the  inside  of  the

machine including the base, side panels, condenser, etc.

Annually:

  Check  if  the  auger  bushings  are    worn  out  or

ovalized. If they are,  replace them with new ones.

Never remove the insulating jacket from around the suction

tubing of the evaporator (the copper tubing located on the right
side of gear motor). In case the insulating jacket is missing
replace the entire parts with original spare parts from the
supplier. 

In  order  to  prevent  any  damages  to  the  dispenser,  all

plastics parts must be lubricated only with grease supplied by
the manufacturer or with another lubricating product suitable for
polycarbonate

.

ATTENTION

In case of damages, the power cord must be replaced by
qualified  personnel  only  in  order  to  prevent  any  shock
hazard.

ATTENTION

Before any disassembly and/or cleaning procedure make
sure  that  the  dispenser  is  disconnected  from  its  power
source by unplugging it.

ATTENTION

Condenser  fins  are  very  sharp.  Use  extreme  caution
when cleaning.

Содержание QUARK 1

Страница 1: ...QUARK MANUALE D ISTRUZIONI OPERATOR S MANUAL CARNET D INSTRUCTIONS GEBRAUCHSANWEISUNG MANUAL DE INSTRUCCIONES...

Страница 2: ...o cool the indicated liquids only 4 Do not introduce dangerous or toxic liquids to the appliance 3 TECHNICAL CHARACTERISTICS The electric diagram of the dispenser is located in the inner part of the d...

Страница 3: ...be diluted with water pour water into bowl first then add correct quantity of product In case of natural squashes it is advisable to strain them in order to prevent pulps from obstructing the faucet o...

Страница 4: ...mperature adjustment in GRANITA mode you can also adjust the minimum temperature of the product when the dispenser is operating in granita mode This minimum temperature is factory set to 10 C If you w...

Страница 5: ...t be turned off when frozen product is in the bowl if not agitated the product may freeze to a solid block of ice If the mixers are turned back on in this situation damage to the mixers and their moto...

Страница 6: ...tion or 1 spoon of sodium hypoclorite diluted with two litres of water according to your local Health Codes and manufacturer s specifications 3 Place the parts in the sanitizing solution for five minu...

Страница 7: ...wl s Drain this solution Do not rinse out the machine 8 ROUTINE MAINTENANCE 1 Daily inspect the machine for signs of product leaks past seals and gaskets If proper assembly does not stop leaks around...

Отзывы: