15
3. Name plate – lifting
capacity marking
Visual check
Lifting capacity is
illegible.
Repair or replace with
the new one.
Point up the lifting
capacity.
4. Deformation of side
plate
Visual check
Visible deformation of
parallelism of the side
plates.
Repair or replace
5. Deformation and
wear of the crossbeam
and suspension
shackle
Visual check or
check by the help of
the slide caliper.
Bent or worn out
cross beam or
suspension shackle
by more than 10%.
Product revision.
Replacement of the
cross beam or the
suspension shackle.
Putting out of
operation.
9 LUBRICATION
9.1 GENERALLY
Before the application of the new lubricant, remove the old one, clean parts by the
solvent and put the new lubricant. Use grease: Universal lithium plastic lubricant,
water resistant, usable in a minimum range of working temperatures from -20°C to
+50°C. For example A2, LV2EP.
! WARNING
All lubricants (grease, oil) used in the NEXP version must have an ignition
temperature higher than 135°C. E.g. LV2EP, Optitemp LG2….
9.2 GEARINGS OF THE PRODUCT
Remove the old lubricant from the gear transmission of the product and replace by a
new one.
10 MAINTENANCE
10.1 SAFETY PRINCIPLES
! WARNING
Only qualified persons (service organizations) trained in safety and
maintenance of these products can carry out maintenance, specialized
inspections and tests.
ALWAYS
use entirely parts supplied by the manufacturer.
It is not permitted to perform repairs and maintenance in other way than specified by
the manufacturer. It concerns especially the forbiddance of using of unoriginal parts
or performing modifications on the product without any approval of the manufacturer.
ALWAYS
check the function of the product after performing maintenance.
ALWAYS
mark the defective product or product under repair by an appropriate
sign (e.g.: „OUT OF OPERATION“).
NEVER
carry out maintenance when a load is suspended on the product.
NEVER
use product, which is under repair!
ALWAYS
when repairing the paint, it is necessary to observe the total thickness
of the paint layer maximum 0,2 mm (or new paint, or after cleaning the
surface new paint, applies to NEXP product design).