background image

1

4

Auto Linkage system

Set-up the hood and hob linkage via the Low Speed Button
on your hood.

The hood is factory set to non-linked mode.

If the hood and hob are not linked, operate the hood manually.

5 - Within 8 seconds, press and hold any of the kk

6 - Connection success.

7 - Once the pairing is done, the hood and the lights will turn on  

   automatically 

**If you do not hear 5 successive beeps, you will need to restart steps 1-5 

again.

For additional assistance, please call Brandt Asie Pte Ltd for support.

RRRRRRRRR

knobs of the Auto Linked

 gas hob, you will hear 5 successive beeps.  

1 - Connect the hood to power source,it will beep once.

2 - Press and hold the "low speed" button for approximatively 8 seconds 
     until you hear 3 beeps.

3 - When the hood beeps 3 times, the low button light will keep shining,the 

pairing mode is activated. 

4 - Restart hood, by turning off and on the power source.

 The hood will beep 3 times. 

8 - In order to disable to Auto Linkage System, press and hold the "low speed"

     button for 8 seconds.When the hood beeps once, the Auto Linkage has been
     closed.

DUCTING VS. RECIRCULATING MODE

You can choose to install the hood as a ducting or recirculating

mode:

Ducting mode (Vented mode)

In the ducting mode, air is drawn into the hood, fat are trapped by
aluminum filters. 

this mode, only the aluminum filters are installed.

Recirculating mode

In the recirculating mode, air is drawn into the hood, fats are trapped by the
filters, the air then passes through charcoal filters to remove cooking
odors, the purified air is then passed back into the kitchen.In this mode,both

the aluminium filters and the charcoal filters must be installed.

5

Odors, fumes and condensation are then expelled to the outside. In 

Содержание AD9905B

Страница 1: ...AD9905B COOKER HOOD ...

Страница 2: ......

Страница 3: ...ent System Requirements Description of Parts Ducting vs Re circulating mode Re circulating mode air outlet Installation Electrical Connection Operation Auto Linkage System Cleaning Maintenance Troubleshooting Schematic Diagram Dimension Drawing 1 1 2 3 4 5 6 7 12 13 14 15 17 18 18 ...

Страница 4: ...e and respect the environment Please help us to continue the protection of the environment by disposing of the packaging in a correct manner Safety Specifications Input Motor LED Light Total Power AC 220 240V 50Hz 1 5W 1 1 x 220 W 225 W Schematic Diagram Dimension drawing 18 Flow rate 1300m3 h 470 470 ...

Страница 5: ...ce may be used safely if it is correctly installed according to the provided safety instruction by a qualified installer The installer is responsible for ensuring that the appliance works correctly at its installation location Brandt Asie Pte Ltd is not liable for damage caused by incorrect installation or connection and such damages are not covered under warranty It is dangerous to modify any par...

Страница 6: ...arcoal filters before use This product is intended for domestic use and the household environment only The product is not intended for an outside use or in a commercial setting Do not leave the product unattended during operation Brandt Asie Pte is not liable for damage caused by improper use or incorrect operation Determine which venting method is best for your application Vented non recirculatin...

Страница 7: ...aces with a commercially available aluminum cleaner Abrasives and scouring agents can scratch stainless steel finishes and should not be used to clean finished surfaces cause irreparable damage appliance to function effectively regular maintenance is a must Clogged filters restrict airflow and may cause the motor to overheat Description of Parts 4 A Metal Air Outlet For recirculating mode AD9905B ...

Страница 8: ...mes the low button light will keep shining the pairing mode is activated 4 Restart hood by turning off and on the power source The hood will beep 3 times 8 In order to disable to Auto Linkage System press and hold the low speed button for 8 seconds When the hood beeps once the Auto Linkage has been closed DUCTING VS RECIRCULATING MODE You can choose to install the hood as a ducting or recirculatin...

Страница 9: ...ct low speed as normal usage Press once to select Medium Suction speed Press once to select High Suction speed Press and hold this button for 3 5s to activate the delay timer The cooker hood will operate for 15 minutes and then switch off automatically when activated Press once to select Booster P The hood will beep once and the light will turn blue flashing If using Auto Linkage mode press and ho...

Страница 10: ...essionals Brandt Asie Pte Ltd is not liable for damages caused by improper handling and installation of the appliance 7 Installation Safety precautions Do not install the cooker hood where there are many doors or windows in order to avoid affecting the exhaust efficiency of the hood caused by air flow Install the cooker hood right above the hob The recommended distance between the hob and the lowe...

Страница 11: ... onto the support screws Fully tighten the support screws Adjust screws Vr to level the hood body 8 DUCTING MODE 1 Wall drilling and bracket fixing Secure the sides of the brackets using 4 screws ST5X40 and screws wall plug 8x40 supplied 2 Fix the cooker hood and Upper Bottom chimney in the wall with screws Secure the sides of the brackets using the 2screws M4X10 supplied Inner ductcover Inner duc...

Страница 12: ...ling and metal air outlet fixing secure the sides of the brackets using the 4 screws ST5 X 40 and the wall plug screws 8x40 supplied 2 Hook the hood body onto the support screws adjust the height and then connect the aluminum foil flue Pls refer RECIRCULATING MODE to picture Fig 1 ...

Отзывы: