PSI BOX Reference
Mode 7 Overview
position 42, it is 1 when there was a syntax error in the previous
string and 0 when no syntax error was detected. This syntax
error flag is of most used for programmed applications whilst the
message ’Error In Command’ is particularly effective during
interactive use.
If any new line of information starts with the characters
BUS, in upper case, then that line is treated as a PSI BOX
command. The PSI BOX processes the command and takes any
necessary action.
If any line of information does not start with BUS then the
PSI BOX treats it as data to be output to the current IEEE
device.
A new line is said to start after a CR or CR+LF character
sequence.
Every BUS command is terminated by a carriage return.
All the parameters in an BUS command are numerals 0-9 or are
any mix of upper or lower case letters, a-z and A-Z, with the
+"= characters. Parameters are separated by spaces or commas.
Extra spaces can be used to separate parameters to make the
commands more readable. These extra spaces are ignored by the
PSI BOX command parser.
The BUS command can contain one or more valid commands in
any sequence desired provided that not more than 128 characters
are sent at any one time. Remember a <CR> must be used to
terminate the string.
BUS SPOLL 6 Listen 5 DATA 65,76,80 EOI 13 UNL <CR>
About 60 IEEE commands are available in MODE 7.
These are listed below. The PSI BOX Mode 7 Quick reference
Card lists the commands and gives the exact BUS command
language syntax. A later chapter in this manual gives command
syntax as well as the IEEE bus activity and data returns that
results from each command.