Page
45
- Installation Manual
24805490/11-01-2013 319F90C
ver
.
1.2 -
The data and information in this manual may be changed at any time with no obligation on BRAHMS’
s par
t t
o notify anyone of this
ENGLISH
STEP 6: Starting up programming
1.
The control unit must be completely shut down.
2.
If parameter
PROGRAM. FROM PC
is:
•
WITH CONTROL UNIT OFF
, launch programming.
•
AFTER USER CODE
, before starting programming you
need to enter the user code.
3.
Open the programming window, select the parameters you want to
use and press launch writing.
Warning: the control unit is running in Autobauding and could require
several seconds to synchronise.
STEP 7: Operating and shutting down the control unit
Once maintenance is finished restore the system to operation mode.
1.
Enter the technical menu.
2.
Put the control unit into operation mode
by lowering the microswitch 1.
3.
Shut down the control unit.
4.
Exit the technical menu.
11 Restore system
Restoring parameters is irreversible and deletes the entire programming.
Restoring parameters does not erase events from memory.
To restore the control unit completely you need to do both factory settings as well as restore the codes.
11.1 Restoring codes and keys
CODES
STATUS
PASSWORD
ASSOCIATED
AREAS
AUTHORISATION
REMOTE CONTROL
ACCESS USER
MENU
1
ACTIVATED
123456
ALL
SWITCHING ON +
SWITCHING OFF
ACTIVATED
ACTIVATED
2 ...
n
DEACTIVATED
Undefined
ALL
SWITCHING ON +
SWITCHING OFF
ACTIVATED
ACTIVATED
All codes are reset; code 1 is set to: 123456
Factory settings for codes and keys is:
KEYS
STATUS
ASSOCIATED AREAS
AUTHORISATION
1 ...
n
DEACTIVATED
ALL
SWITCHING ON + SWITCHING
OFF
All keys are reset.
To restore factory settings codes, you need to:
STEP 1: Setting the micro switches
1.
Set micro switch 2 to ON.