INSTALLATION MANUAL

SECURITY ALARM CONTROL UNIT

 

English

EN

English

EN

Содержание proxinet8

Страница 1: ...INSTALLATION MANUAL SECURITY ALARM CONTROL UNIT English EN English EN...

Страница 2: ...ER 16 BUS RS 485 17 INPUTS 17 U1 PROGRAMMABLE OUTPUT positive 17 U2 U3 U4 Open Collector PROGRAMMABLE OUTPUTS 17 GENERAL ALARM RELAY OUTPUT RELAY 1 18 PSTN TELEPHONE LINE WITH PXTEL BOARD 18 LANGUAGE...

Страница 3: ...ATING SCENARIO VIA KEYPAD 35 ASSOCIATING SCENARIOS AND INSERTERS 36 9 7 PROGRAMMING INPUTS 37 9 8 PROGRAMMING OUTPUTS 38 9 9 PROGRAMMING TELEPHONE CALLS AND SMS TEXT MESSAGES PSTN GSM 38 PROGRAMMING T...

Страница 4: ...t and clearly communicate any product flaws or shortcomings within two months of noticing The warranty loses validity if any user fails to communicate any flaws within the above mentioned terms Any cl...

Страница 5: ...ystem wiring Remote PC SA10L External siren LAN Network Local PC PXWEB LAN Interface Switch PXTEL PSTN Combiner PXGSM GSM Combiner PXTAG Transponder key Bus RS485 PXKWD LCD Keypad PXKI LED Keypad sms...

Страница 6: ...communication LEDs featured on each device should be flashing If some are not flashing this means installation or programming was wrong check cabling address and programming in control unit TRADITIONA...

Страница 7: ...tallation Manual 24805490 11 01 2013 319F90C ver 1 2 The data and information in this manual may be changed at any time with no obligation on BRAHMS s part to notify anyone of this ENGLISH DOUBLE BRAN...

Страница 8: ...tallation Manual 24805490 11 01 2013 319F90C ver 1 2 The data and information in this manual may be changed at any time with no obligation on BRAHMS s part to notify anyone of this ENGLISH BUS AMPLIFI...

Страница 9: ...fall below 12 V DC If less add an auxiliary power source and disconnect the positive while keeping the negative mutual In case of long stretches of bus always install 150 ohm resistors among terminals...

Страница 10: ...5 mm cable plus an auxiliary power source at the end of the line as shown below CABLE RS 485 Screened 2x1 5mm twisted 2x0 22mm CABLE RS 485 Screened 2x0 5mm twisted 2x0 22mm Control unit Device on bus...

Страница 11: ...7 kohm resistors Yellow 4 Violet 7 Red x100 Gold 5 4 7 kohm 5 resistor CONNECTING INPUTS The U1 output gives a positive when output is active ON 13 8Vdc The U1 output is factory programmed as TC activ...

Страница 12: ...ative operating humidity 25 75 R H No condensation Relative storage humidity 25 75 R H No condensation Standard compliant CEI EN 50131 WORK CHARACTERISTICS Inputs in control unit 8 Alarm outputs 1 Out...

Страница 13: ...f system switched off Alarm Red On At least one associated area is in alarm mode system in alarm mode Blinking The system has detected an alarm and dampened it See event history for alarm list To remo...

Страница 14: ...2 Connector for PXGSM module connection k CN1 Connection for connecting the voice board PXV64 PXV256 and language board l M1 Terminal board for transformer connection m CN5 JP1 CN5 Connector for PXSTB...

Страница 15: ...the wall 5 5 Cabling Cut off the magnetothermic switch linked to the control unit before the network 230 Vac and for the entire time the control unit is open Connect the Line cable and the Neutral of...

Страница 16: ...CN6 M6 M7 SW1 JP3 O C RELAY TAMPER Vac M1 CN3 CN2 CN1 1 2 3 4 ON BAT BAT JP1 CN5 CN4 PXSTB JP1 Page 16 Installation Manual 24805490 11 01 2013 319F90C ver 1 2 The data and information in this manual...

Страница 17: ...rammed as a TC to abate microwaves when system is switched off U1 OFF if at least one area is on during out times U1 ON if the system is completely switched off The output is protected by a 100 ohm re...

Страница 18: ...rogrammed Siren requiring power supply Siren with on board power supply PSTN TELEPHONE LINE WITH PXTEL BOARD LANGUAGE UPDATE BOARD PXLNG for control unit The PSTN telephone line needs to be connected...

Страница 19: ...pply voltage 12 Vdc 15 Vdc Max power draw 60 mA Working temperature 0 40 C Relative humidity 25 75 without condensation Dimensions HxLxD 180x120 x 28 wall surface mounted IP IP40 6 2 Card description...

Страница 20: ...areas 4 LIGHT WARNINGS LED STATUS LEGEND OF LIGHT SIGNALS When off it means there are open entrances associated to the keypad Alarm is raised when a scenario is brought up Check open entrances when s...

Страница 21: ...press and hold down the key for at least 5 seconds KEYPAD LANGUAGE Changing the keypad menu language does not change the control unit language If you want to change the keypad menu 1 Press and hold do...

Страница 22: ...history 7 PXITxxxx Inserters The inserters must be mounted so as to be protected from any breaking in attempts or in an area guarded by the system otherwise the reference regulation becomes not applic...

Страница 23: ...ea of scenario 3 which is in alarm mode during going out time it means that at least one entrance associated to scenario 3 is open LED 4 Red When off it means the associated areas are switched off sys...

Страница 24: ...M2 M3 P1 CN6 M6 M7 SW1 JP3 O C RELAY TAMPER Vac M1 CN3 CN2 CN1 1 2 3 4 ON BAT BAT JP1 CN5 CN4 PXV64 All the board insertion and removal operations must be performed with the control unit s power suppl...

Страница 25: ...75 without condensation CARD DESCRIPTION DESCRIPTION 1 Board connector to control unit 2 Terminal board for telephone line connection 3 Red PSTN line status LED Off Communication NOT active On Communi...

Страница 26: ...section Control Unit language update board PXLNG in this manual Updating the language makes it possible to update the firmware as well 9 Starting up the system This chapter aims to describe how to st...

Страница 27: ...tamper or due to possible programming errors we suggest placing the control unit into maintenance mode 1 Place the control unit into maintenance mode ON 1 by raising microswitch 1 STEP 3 Maintenance...

Страница 28: ...control when skilled installing technicians are involved 08 23 16 05 10 ENTER CODE 123456 STANDING BY USER MENU 222222 MODE OF 01 PROGRAMMING PROGR MODE EASY Programming mode EASY only base parameter...

Страница 29: ...area is switched on U4 Technical yields a negative when at least one technical alarm is active RELAY Relay 1 is activated during the alarm time CODES CODE PROPERTIES KEYS DESCRIPTION OF PROPERTIES al...

Страница 30: ...ESC key for 5 sec and enter the Technical code 3 With select SYSTEM and press 4 With select ADDRESSING KEYPADS and press 5 With select the index of the keypad you wish to acquire example keypad 2 ON...

Страница 31: ...e the menu SYSTEM 2 With select ADDRESSING INSERTERS and press 3 The display shows the inserter address which was not found on bus and which needs to be addressed 4 Using a key even one not accepted a...

Страница 32: ...the expansion address which you need to activate by adding activated deactivated 7 Press to exit and return to the previous menus STEP 2 Modify description of areas 1 Staying within the Technical Menu...

Страница 33: ...on on areas not available on EASY mode Defines the action you want on the areas switching on off 1 Staying within the Scenarios Menu 2 With select AREA ACTION 3 With set the parameter to EXACT ON OFF...

Страница 34: ...ON and press 3 Use the keys to edit text 4 Use the keys to move down one character at a time 5 Press to confirm and return to previous menus Press to cancel the change DESCRIPTION XX SCENARIO XX SCENA...

Страница 35: ...e SWITCHING ON VIA SCENARIOS key you wish to associate the scenario to 7 With you can set the scenario to launch NO to deactivated the key 8 Press to exit and return to the previous menus 08 23 16 05...

Страница 36: ...ciate to LED 1 otherwise select LED 2 or LED 3 6 With you set the scenario to launch NO to disable the LED light 7 Press to exit and return to the previous menus 08 23 16 05 10 ENTER CODE 123456 STAND...

Страница 37: ...d return to the previous menus 08 23 16 05 10 ENTER CODE 123456 STANDING BY USER MENU 222222 INPUTS 11 CHANGE INPUTS XXX INPUT XXX STATUS XXX INSERTED TYPE XXX SWITCH ON BALANCING XXX SINGLE BAL AREAS...

Страница 38: ...access the Technical Menu press the ESC key for 5 sec followed by the User code if under 6 digits confirm with 2 Press the ESC key for 5 sec and enter the Technical code 3 With select TELEPHONE OPTION...

Страница 39: ...the keys to edit the telephone number to cancel backwards 7 Press to confirm and return to the previous menus 8 Press to exit and return to the previous menus 08 23 16 05 10 ENTER CODE 123456 STANDING...

Страница 40: ...d be wrong it should be re written as resume without the accent To send modified voice messages to the control unit you need to 1 The control unit must be completely shut down 2 Open the programming w...

Страница 41: ...ated deactivated 6 With select STATUS 7 The activates it and the deactivates it 08 23 16 05 10 ENTER CODE 123456 STANDING BY USER MENU 222222 CODES 16 USER CODES CODE 001 USER 001 CODE 002 USER 002 ST...

Страница 42: ...to be read on inserter 1 and wait for the LED to blink in confirmation of successful acquisition 7 The display shows the message ACQUIRED KEY with buzzer sound active Press to continue 8 Press to out...

Страница 43: ...e if under 6 digits confirm with 2 Press the ESC key for 5 sec and enter the Technical code 3 With select SYSTEM and press 4 With select TEST SYSTEM and press 5 With select the parts of the system you...

Страница 44: ...AMPER M1 CN3 CN2 CN1 1 2 3 4 ON STEP 3 Connecting the PC the control unit 1 Install the control unit programming software onto your PC 2 Connect the control unit to the PC via a RS 232 standard cable...

Страница 45: ...technical menu 2 Put the control unit into operation mode by lowering the microswitch 1 3 Shut down the control unit 4 Exit the technical menu 11 Restore system Restoring parameters is irreversible an...

Страница 46: ...don t delete codes or keys already in memory To delete this items it s necessary to enter in the specific menu To set all the devices to the default parameters do as follow 1 To access the Technical M...

Страница 47: ...ents For Pan European Approval For Connection To The Analogue Public Switched Telephone Networks Pstns Of Te Excluding Te Supporting The Voice Telephony Service In Which Network Addressing If Provided...

Страница 48: ...Page 48 Installation Manual 24805490 11 01 2013 319F90C ver 1 2 The data and information in this manual may be changed at any time with no obligation on BRAHMS s part to notify anyone of this ENGLISH...